VLT® Modbus TCP MCA 122
High performance Modbus TCP eldbus option for VLT® AutomationDrive, VLT® HVAC Drive
and VLT® AQUA Drive.
Ordering number
Uncoated 130B1196
Co at ed 130 B1296
The VLT® Modbus TCP MCA 122
Option oers connectivity to Modbus
TCP based networks, such as Groupe
Schneider PLC system via the Modbus
TCP Protocol.
The option is able to handle a single
connection with an Actual Packet
Interval down to 5 ms in both directions, positioning it among the fastest
performing Modbus TCP devices in
the market.
Other features:
Built-in web-server for remote
diagnosis and reading out basic drive
parameters.
An E-mail noticator can be congured for sending an e-mail message
to one or several receivers, if certain
warnings or alarms occur, or have
cleared again.
MCA 122 was introduced in 1998 and
is today one of the most developed,
proven and complete industrial
Ethernet network solutions available
for manufacturing automation.
MCA 122 is a member of a family
of networks that implements the
Modbus protocol at its upper layers.
Modbus encompasses a suite of
messages and services for a variety of
manufacturing automation applications, including control, conguration
and information.
As a truly media-independent
protocol that is supported by hundreds of vendors around the world,
Modbus TCP provides users with a
unied communication architecture
throughout the manufacturing
enterprise.
The plug and play option can be
installed in VLT® HVAC Drive,
VLT® AQUA Drive and VLT® AutomationDrive frequency converters
Application protocols
n EtherNet/IP (Industrial Protocol) for
controlling and parameter setting
n CIP (Common Industry Protocol)
For communication to the PLC
n HTTP (Hypertext Transfer Protocol)
for diagnosis via build-in web server
n SMTP (Simple Mail Transfer
Protocol) for e-mail notication
n DHCP (Dynamic Host
Conguration Protocol) automatic
IP address conguration
n TCP/IP (legacy TCP/IP) transparent
Socket Channel connection to
VLT® Motion Control Tool MCT10
Feature Benet
Connectivity to Modbus TCP based networks
Actual Packet Interval down to 5 ms
Built-in web-server
E-mail noticator Noties if warnings or alarms occur
Two Ethernet ports with built-in switch
Support of dual PLC Masters
Connects to Groupe Schneider PLC systems
and to various SCADA systems
High performance
Remote diagnosis and reading out of
basic drive parameters
• Simple cabling
• No need for expensive switches or hubs
Allows the use of redundant Masters for
bumbles control transfer
Facts about our products

The VLT® Modbus TCP MCA 122 does
not require any special conguration
le to be loaded into the PLC’s
programming tool.
It simply Integrates by entering the IP
address and holding registers. It can’t
become more simple like that
Danfoss VLT D rives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80
www.danfoss.com/drives • info@danfoss.com
DKDD.PFO.605.A2.02 VLT® is a trademark of Danfoss A/S PE-MMSC 2014.09