Danfoss MCA 113 Fact sheet

VLT® PROFIBUS Converter MCA 113
Keep the functionality of the VLT® 3000 Probus without changing the PLC program.
Ordering number
Co ate d 130 B1245
VLT® PROFIBUS Converter MCA 113 emulates the VLT® 3000 commands on the PROFIBUS network. All VLT 3000 commands from the PLC are translated in the MCA113 to VLT® AutomationDrive FC 302 commands. This eliminates the need to rewrite the PLC program and change the conguration.
As a result the PLC investment is retained and no expensive and time consuming reprogramming is required. Production downtime is reduced to a minimum, where the FC302 now becomes plug-and-play compatible with the VLT®3000 Probus.
For easy mechanical adaptation, accessory adaptor plates with VLT 3000 mounting holes ensure correct tting of the FC 302 in panels or on walls.
Easy and compatible
n
Emulates all VLT 3000 PPO types
n
Delivered pre-installed in a stan­dard FC 302 or as eld mountable option
n
A-cyclic parameterization using PCA channel is converted to FC 302 parameters
n
Supports the two-state machines of
the VLT® 3000
n
Communication using PROFIBUS DP-V0, Master Class 1
n
VLT® 3000 optimized PLC program do not need to be changed when
upgrading/retrotting
n
Spare parts stock can be reduced to
FC302 parts only
40 million
devices worldwide. PROFIBUS is the world’s most successful fieldbus, widely used in process automation, motion control and safety related tasks.
Feature Benet
Ecient
Reuses the VLT 3000 GSD le
Accepts the VLT 3000 PPO1 to PPO8 No need to rewrite the PLC program
Mounts in a FC302 Reduced spare part list
VLT
® Motion Control Tool MCT10 Support
via USB and RS485
VLT 3000 diagnosis Fast recovery from fault
Conguration of process data via GSD-le
Same PROFIBUS connector style
No need to change the PLC’s hardware conguration in the PLC
Full access of FC 302 parameters, where the new features of the FC 302 are accessible (e.g. Logging, scope)
All communication settings are handled in the PLC
Installed bus connector can be reused or the new color coded connector can be used.
Facts about our products
Save installation time with adaptor plates
Reduce downtime and mounting costs when exchanging a VLT® 3000 with a VLT® AutomationDrive FC 302. Pre-drilled adaptor plates make it easy to mount a new FC 302 fre­quency converter in place of a VLT
3000.
Not only does this reduce installation costs, it also eliminates the need for additional modications to the cabinet or panel where the new drive is installed. Drilling new holes and cutting new threads can coarse chips to damages electronic parts.
Owners can therefore exchange old drives with new drives in existing systems with ease. This is an advan­tage when a high degree of exibility in upgrade strategies is required.
Adaptor plate, FC302 and a PROFIBUS converter MCA113 can easily replace a VLT3000
Danfoss Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, www.danfoss.com/drives • E-mail: info@danfoss.com
DKDD.PFO.612.A2.02 VLT® is a trademark of Danfoss A/S PE-MMSC 2014.09
Loading...