Danfoss MC10-RO Technical Information

Pilot Operated Check Valves Technical Information
300
100
200
gal/min
10 = 10 bar [145 psi]
Reverse Pilot to Open
OPERATION
SPECIFICATIONS
DIMENSIONS
mm [in]
45-50 N•m [33-37 lbf•ft]
27mm
This is a pilot-to-open check valve.
Theoretical performance
26 cSt [121 SUS] hyd.oilat 50°C[122°F]
psi
bar
25
20
15
10
5
10 bar
0
36912
5 bar
1 bar
15
Cross-sectional view
3
7/8-14 UNF-2A
605040302010
US
Free Flow 2 to 1
Pilot override 1 to 2
l/min
Schematic
Specications
Rated pressure 250 bar [3600 psi]
Rated ow at 7 bar
[100 psi]
Leakage 6 drops/min @
Weight 0.12 kg [0.26 lb]
Pilot ratio 3.0:1
Cavity SDC10-3S
Note: A piston seal requires a 4.5 bar [65 psi] or
greater return spring.
45 l/min
[12 US gal/min]
Rated pressure
ORDERING INFORMATION
8 [0.31]
Crack Pressure
1 = 1 bar [15 psi]
5 = 5 bar [73 psi]
Piston seals
Omit = No seal OR = Seals included
1.6 [0.06]
37.04 [1.46]
MC10-RO-5-OR-A-B-6S
1
Ø 1.2 [0.83]
2
P103 753
Housing and portsHousing P/N
00 =No Housing No Housing SE3B =Al,3/8 BSPSDC10-3S-SE-3B SE4B =Al,1/2 BSPSDC10-3S-SE-4B
6S =Al,#6 SAESDC10-3S-6S/6S
8S =Al,#8 SAESDC10-3S-8S/6S Other housings available
Seals
B = Buna-N V =Viton
Seal kit
35401419
35401519
BC332375625108en-000101 • February 2020
PO - 11