Data Sheet
Isolation valve
Type MBV 2000
Designed for mounting between Danfoss pressure transmitters
The MBV 2000 isolation valve is designed for
mounting between Danfoss pressure
transmitters with DIN 3852 - E pressure
connection and uid-lled systems.
The isolation valve automatically closes when a
transmitter is removed, so transmitters can be
changed easily without having to rst drain a
system. The valve reopens when a transmitter is
connected.
Features
• Compact design
• Fast and easy installation and removal
• Simple and eective isolation
AI225186435108en-000301
Operating pressure
Burst pressure
All metal parts in contact with the medium
DIN 17440-1.4404 (AISI 316 L)
The valve is impervious to fuel oil, oil and air
It is not recommended for use with petroleum, combustible gasses or corrosive chemicals.
Isolation valves are supplied with two plastic protective covers which should be removed prior to use.
For safety, it is essential that the isolation valve is thoroughly secured to the system prior to connecting / disconnecting a transmitter. The valve must not become loose when a transmitter is being removed.
It is recommended to remove or t transmitters at a system pressure below 40 bar.
Isolation valve, type MBV 2000
Product specication
Technical data
Table 1: Performance
Table 2: Materials
Table 3: Mounting
Application note
The MBV 2000 must only be used to connect Danfoss transmitters with a pressure connection in compliance to
DIN-3852-E.
Specication and code numbers for standard types
© Danfoss | Climate Solutions | 2021.02 AI225186435108en-000301 | 2