Danfoss MBT 5550 Data sheet

Data Sheet

Temperature sensor

Type MBT 5550

With the MBT 5550 we have combined our temperature transmitter with a detachable thermowell MBT 120 enabling replacement of the transmitter while the application is in operation.

The MBT 5550 is designed for use in harsh environments where reliable, robust, and accurate equipment is required.

Features

• Designed for use in harsh marine & industrial environments where reliable, robust, and accurate equipment is required

• All metal enclosure parts made of stainless steel (AISI316)

• Output signals: 4 – 20 mA or Ratiometric 10 – 90%

• A wide selection of process and electrical connections are available

• Compact design

• Measuring range -15 to 200 °C

• Based on Pt 1000 sensor technology

AI391832931068en-000102

Temperature sensor, Type MBT 5550

Product speci€cation

Technical data

Table 1: Main speci€cations

Features

Description

Process connections

See page Ordering

Measuring ranges

Any combinations between -15 ‒200°C

Minimum span

50 °C

Output signals

4 – 20 mA or Ratiometric 10 – 90%

Electrical connections

See page Electrical connection

 

 

Table 2: Performance

 

 

 

 

Indicative response times

 

 

Features

Water 0.2 m/s

 

 

Air 1 m/s

 

 

t0.5

t0.9

t0.5

t0.9

 

ø8 mm

10 s

35 s

95 s

310 s

 

Accuracy

 

Typical: < ± 0.5% FS, Maximum: < ± 1.0% FS

 

 

Max. load protection tube

 

 

100 bar

 

 

 

 

 

 

 

Table 3: Electrical speci€cations

 

Features

 

Nom. Output signal (short-circuit protected)

 

4 – 20 mA

Ratiometric 10 – 90% of supply voltage

 

 

 

Supply voltage [US] polarity protected

10 – 30 V DC

4.75 – 8 V DC

 

 

 

5 V DC (Nom.)

 

Supply – current consumption

-

< 4 mA at 5 V DC

 

Insulation resistance

> 100 MΩ at 100 V DC

> 100 MΩ at 100 V DC

 

Supply voltage dependency

< ± 0.05% FS/10 V

-

 

Current limitation

30 mA

-

 

Output impedance

-

< 25 Ω

 

Load [RL]

RL<(US-10) / (0.02 A) ohm

RL> 5 kohm at 5 V DC

 

 

 

 

Table 4: Environmental conditions

Features

 

Description

Media temperature

 

-15 ‒200 °C

Temperature on electronics(1)

 

-40 – 85 °C

Transport temperature range

 

-50 – 85 °C

EMC – Emmision

 

EN 61000-6-3

EMC – Immunity

 

EN 61000-6-2

 

Sinusoidal 15.9 mm-pp, 5 – 25 Hz

-

 

 

 

 

Vibration stability

4 g, 25 Hz – 2 kHz

IEC 60068-2-6

 

Random 7.5 gms, 5 Hz – 1 kHz

IEC 600868-2-34, IEC 60068-2-36

Shock resistance

Shock 500 g/1 ms

IEC 60068-2-27

Free fall

IEC 60068-2-32

 

 

 

 

Enclosure (depending on electrical connections)

See page Electrical connection

 

 

 

(1) Temperature of the electronics depends on the media temperature, extension length, ambient temperature and air velocity.

Table 5: Mechanical characteristics

Features

 

Description

Materials

Wetted parts

W.no. 1.4571 (AISI 316 Ti)

Enclosure

W.no. 1.4404 (AISI 316 L)

 

Measuring insert

 

Fixed

Net weight (depending on design)

 

0.15 ‒0.2 kg

© Danfoss | Climate Solutions | 2022.03

AI391832931068en-000102 | 2

Danfoss MBT 5550 Data sheet

Temperature sensor, Type MBT 5550

Electrical connection

Table 6: Electrical connection

EN 175301-803

AMP Econoseal

IEC 947-5-2

Flying leads

2 m screened cable

J series (male)

M12 × 1

 

 

 

<![if ! IE]>

<![endif]>Danfoss 60G330

<![if ! IE]>

<![endif]>Danfos 60G378

<![if ! IE]>

<![endif]>Danfoss 60G332

<![if ! IE]>

<![endif]>Danfoss 60G333

<![if ! IE]>

<![endif]>Danfoss 60G282

 

 

Enclosure

 

 

IP65

IP67

IP67

IP67

IP67

 

 

Materials

 

 

Glass ‡lled polyamid, PA 6.6

Glass ‡lled polyamid, PA 6.6

Glass ‡lled polyamid, PA 6.6

Glass ‡lled polyamid, PA 6.6

PUR

 

Electrical connection, 4 – 20 mA output (2 wire)

 

Pin 1: +supply

Pin 1: +supply

Pin 1: +supply

Red wire: +supply

Red wire: +supply

Pin 2: ÷supply

Pin 2: ÷supply

Pin 2: Not used

Black wire: ÷supply

White wire: ÷supply

Pin 3: Not used

Pin 3: Not used

Pin 3: Not used

 

Red/black wire: Not used

Earth: connected to MBT

 

Pin 4: ÷supply

 

Screen: connected to MBT

housing

 

 

 

housing

 

Electrical connection, Ratio metric (3-wire) 10 – 90%

 

Pin 1: +supply

Pin 1: +supply

Pin 1: +supply

Red wire: +supply

Red wire: +supply

Pin 2: ÷supply

Pin 2: ÷supply

Pin 2: not used

Black wire: ÷supply

White wire: ÷supply

Pin 3: Output

Pin 3: Output

Pin 3: Output

Blue wire: Output

Red/black wire: Output

Earth: connected to MBT

 

Pin 4: ÷supply

 

Screen: connected to MBT

housing

 

 

 

housing

© Danfoss | Climate Solutions | 2022.03

AI391832931068en-000102 | 3

Loading...
+ 4 hidden pages