Data Sheet
Temperature sensor
Type MBT 5270
Compact temperature sensor for harsh marine applications.
The flexible temperature sensor MBT 5270 can be used in many marine and industrial applications such as: Air Compressors, Mobile Hydraulics and Marine EGR systems. In other words applications where robustness, size and performance are essentials.
The sensor can be equipped with different sensing elements (RTD and NTC).
Features:
• OEM Temperature Sensor program
• Various sensor elements available (RTD and NTC)
• Robust, high protection against moisture
• Fixed measuring insert
• Stainless steel
• Very low response times
• Temperature range up to 300 °C
• Available with cable and plug
AI298141313986en-000201
Temperature sensor, Type MBT 5270
Product speci€cations
Technical data
Cable version
Figure 1: Cable version
<![if ! IE]> <![endif]>Danfoss |
<![if ! IE]> <![endif]>84Z8217 |
Table 1: General data
Features |
Description |
|
|
||
|
|
PVC |
-40 – 100 °C |
||
|
Cable |
Silicon |
-40 – 200 °C |
||
|
Teflon |
-40 – 200 °C |
|||
|
|
||||
Ambient temperature |
|
|
|
||
|
Polyole…n (oil resistant) |
-40 – 150 °C |
|||
|
|
AMP spade |
-40 – 200 °C |
||
|
Plug |
AMP Junior Power Timer |
-40 |
– 125 °C |
|
|
|
|
|
|
|
|
|
Deutsch DT04-3P |
-40 |
– 125 °C |
|
Media temperature |
Pt 100 |
-50 |
– 300 °C |
||
NTC |
-50 |
– 150 °C, Special versions up to 300 °C |
|||
|
|
||||
Max. external pressure |
Operating pressure |
400 bar |
|||
Burst pressure |
Max. 500 bar |
||||
|
|
||||
|
|
|
|||
Max. tightening torque |
M14 |
24 Nm |
|||
|
|
|
|
|
Table 2: Performance
Features |
|
Description |
Sensor Element |
|
Pt 100, Pt 1000, NTC |
Process Connection |
|
Refer to ordering standard, see page Cable version |
Sensor insertion length |
Stainless steel |
35 mm @ d ≤ 5 mm |
|
|
Stripped wire ends |
Electrical Connection |
|
Cable with AMP spade (6.35) |
|
Cable with Deutsch DT04-3P-2P |
|
|
|
|
|
|
Other on request |
Connection |
|
2, 3 or 4 wire (depending on electrical connection) |
|
|
|
Table 3: Indicative response times
|
|
|
Indicative response times |
|
|
Material protection tube |
Protection tube |
|
Water 0,2 m/s |
|
|
|
t0.5 |
t0.9 |
|
Stainless steel |
ø3 mm |
0.5 s |
1.5 s |
|
|
|
|
|
Response times can vary very much depending on the design of the sensor and the temperature element chosen.
Table 4: Mechanical and environmental speci€cations
Features |
Description |
|
|
Sensor tolerances |
Pt 1000 / Pt 100 |
EN 60751 Class B: ± (0.3 + 0.005 × t) |
|
NTC |
On request |
||
|
|||
|
|
|
|
Vibration stability |
Shock |
50 g / 6 ms |
|
Vibrations, x-y-z directions |
15.3 g sine, 20 – 2000 Hz, 8 hours |
||
|
|||
|
|
|
|
|
Sensor only |
IP67 according to IEC 60529 |
|
|
|||
Enclosure |
Cable with AMP spade |
IP00 according to IEC 60529 |
|
Cable with AMP Junior Timer |
IP65 according to IEC 60529 |
||
|
|||
|
Cable with Deutsch DT04 |
IP65 according to IEC 60529 |
|
|
|
|
© Danfoss | Climate Solutions | 2021.02 |
AI298141313986en-000201 | 2 |
Temperature sensor, Type MBT 5270
Table 5: Materials
Features |
Description |
Protection tube in contact with media |
AISI 316 |
Process connection |
AISI 316 |
Cable |
PVC, Silicon, Teflon (other on request) |
Gasket |
Viton, NBR (other on request) |
|
|
Integrated plug version
Figure 2: Integrated plug version
<![if ! IE]> <![endif]>Danfoss |
<![if ! IE]> <![endif]>84Z822 |
Table 6: General data
Features |
|
Description |
|
Ambient temperature |
Plug |
-40 – 125 °C |
|
|
Pt 1000, Pt 100 |
-50 – 300 °C |
|
Media temperature |
NTC |
-50 – 150 °C |
|
|
|
special versions up to 300 °C |
|
|
|
|
|
Max. external pressure |
Operating pressure |
400 bar |
|
Burst pressure |
> 500 bar |
||
|
|||
|
|
|
|
Max. tightening torque |
M8 |
10 Nm |
|
|
|
|
Table 7: Performance
Features |
|
Description |
|
Sensor Element |
|
Pt 100, Pt 1000, NTC |
|
Process Connection |
|
Refer to ordering standard, see page Integrated plug version |
|
Sensor insertion length |
Stainless steel |
70 mm @ d ≥ 8 mm |
|
50 mm @ 8 > d > 5 mm |
|||
|
|
||
Electrical Connection |
|
M12 x1 |
|
Connection |
|
2 wire |
|
|
|
|
Table 8: Indicative response times
|
|
|
|
Indicative response times |
|
Material protection tube |
Protection tube |
|
Water 0,2 m/s |
|
|
|
t0.5 |
t0.9 |
|
Stainless Steel |
ø6 mm |
6 s |
18 s |
|
|
|
|
|
Response times can vary very much depending on the design of the sensor and the temperature element chosen.
Table 9: Mechanical and environmental speci€cations
Features |
Description |
|
|
Sensor tolerances |
Pt 1000 / Pt 100 |
EN 60751 Class B |
|
NTC |
On request |
||
|
|||
|
|
|
|
Vibration stability |
Shock |
50 g / 6 ms |
|
Vibrations, x-y-z directions |
15.3 g sine, 20 – 2000 Hz, 8 hours |
||
|
|||
|
|
|
|
Enclosure |
M12 x 1 |
IP65 according to IEC 60529 |
|
|
|
|
Table 10: Materials
Features |
Description |
Protection tube in contact with media |
AISI 316 |
Process connection |
AISI 316 |
Gasket |
Viton, NBR (other on request) |
Plug |
PPS (Ryton 4) |
|
|
© Danfoss | Climate Solutions | 2021.02 |