Danfoss MBS 9300 Data sheet [zh]

MBS 9300

MBS 9300

4–20 mA40–250 mbar -70–70 mbar

EMC/EMI

 

 

 

 

• 40 – 400bar

 

 

 

-40–70 mbar (lowest zero point –

 

 

 

150 mbar)

 

 

- Max full scale 250 mbar

With build-in clipping function and

 

 

 

self-diagnostic features on request

 

4 – 20 mA and Ratiometric

 

 

 

10-90% of supply

 

(AISI 316L)

 

 

10

 

 

 

 

 

 

 2 

 

DNV GL EU RO Mutual Recognition

 

LRS

 

RINA

 

BV

 

ABS

 

KR

© Danfoss | DCS (im) |2020.10

AI176386432536zh-CN0701 | 1

Danfoss MBS 9300 Data sheet

| , MBS 9300

 

Performance (EN 60770)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full-scale span (FSS)

 

 

40

60

 

100/140

 

150

 

250/400

 

mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy @ 25 °C

 

 

≤ ± 2

≤ ± 1.5

 

 

≤ ± 1

 

≤ ± 0.5

≤ ± 0.5

 

% FSS typ.

 

(incl. non-linearity, hysteresis and repeatability)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-linearity (BFSL)

 

 

≤ ± 0.2

≤ ± 0.2

 

≤ ± 0.2

 

≤ ± 0.2

≤ ± 0.2

 

% FSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hysteresis and repeatability

 

 

≤ ± 0.1

≤ ± 0.1

 

≤ ± 0.1

 

≤ ± 0.1

≤ ± 0.1

 

% FSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total error band (TEB)

 

 

≤ ± 5

≤ ± 3

 

 

≤ ± 2

 

≤ ± 1.5

≤ ± 1.5

 

% FSS

 

within compensated temperature range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting position error for 180° rotation

 

≤ ± 1.25

≤ ± 0.8

 

≤ ± 0.5

 

≤ ± 0.35

≤ ± 0.2

 

% FSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload pressure (static)

 

 

3.5

3.5

 

3.5

 

3.5

 

3.5

 

bar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burst pressure

 

 

50

50

 

50

 

50

 

50

 

bar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response time

 

 

 

 

 

 

 

 

 

 

< 2 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resolution

 

 

 

 

 

 

 

 

 

 

Infinite

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Durability P: 10 – 90% FS

 

 

 

 

 

 

 

 

10 × 106 pressure cycles

 

Full-Scale Span (FSS) is the difference between the upper limit and the lower limit of the pressure range.

 

 

(e.g. for pressure range -30 – 30 mbar, FSS = 60 mbar.)

 

 

 

 

 

 

 

 

 

 

 

 

Electrical specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nom. output signal (short circuit protected)

 

 

 

4 – 20 mA

 

 

 

 

Ratiometric 10-90% supply

 

 

 

 

 

 

 

 

 

 

Supply voltage [UB], reverse polarity protected

 

9 – 32 V DC

 

5 V DC +/- 10%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply voltage dependency

 

 

 

< ± 0.05% FSS / 10 V

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

Load [RL] (load connected to 0 V)

 

 

 

RL ≤ (UB - 8 V) / 0.02 A

 

RL ≥ 1.5 kΩ

 

 

Supply current consumption

 

 

 

-

 

 

 

 

 

≤ 6 mA

 

 

Sink / Source

 

 

 

-

 

 

 

 

 

3.3 mA

 

 

Output impedance

 

 

 

-

 

 

 

 

 

≤ 25 Ω

 

 

Environmental specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Media temperature range

 

FPM gasket

 

 

 

 

 

 

-20 – 100°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NBR gasket

 

 

 

 

 

 

-25 – 85 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature range

 

 

 

 

 

 

 

 

See page 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compensated temperature range

 

 

 

 

 

 

 

 

0 – 80 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transport / storage temperature range

 

 

 

 

 

 

 

 

-40 – 125 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMC - Emission

 

 

 

 

 

 

EN 61000-6-3 and EN61236-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMC Immunity

 

 

 

 

 

 

EN 61000-6-2 and EN61236-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.9 mm-pp, 2 Hz

 

 

 

 

 

 

 

 

 

 

 

 

Sinusoidal

– 25 Hz

 

 

 

 

 

 

IEC 60068-2-6

 

 

Vibration stability

 

 

 

20 g, 25 Hz – 2 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Random

7.5 grms, 5 Hz – 1

 

 

 

 

 

IEC 60068-2-64

 

 

 

kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shock resistance

Shock

500 g / 1 ms

 

 

 

 

 

IEC 60068-2-27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Free fall

1 m

 

 

 

 

 

 

IEC 60068-2-32

 

 

 

 

 

 

 

 

 

 

 

Enclosure (depending on electrical connection)

 

 

 

 

 

 

See page 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explosive atmospheres

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone 2 applications 1)

 

 

 

 

 

 

 

 

EN60079-0; EN60079-15

 

 

 

 

-10 ˚C < Ta < + 85 ˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) When used in ATEX Zone 2 areas at low temperatures the cable and plug must be protected against impact.

 

 

Mechanical specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

 

 

 

 

 

 

 

0.2 – 0.3 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical connector

 

 

 

 

 

 

 

 

See page 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure connection

 

 

 

 

 

 

 

 

see page 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Materials, wetted parts

 

 

 

 

 

 

EN 10088; 1.4404 (AISI 316 L)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 | AI176386432536zh-CN0701

© Danfoss | DCS (im) | 2020.10

Loading...