Danfoss MBS 5100, MBS 5150 Data sheet

Data Sheet
Pressure transmitter Type MBS 5100 and MBS 5150
For marine applications
The ship approved high accuracy block pressure transmitter is designed for use in almost all marine applications. MBS 5150 with integrated pulse snubber is designed for use in marine applications with severe medium inuences like cavitation, liquid hammer or pressure peaks and oers a reliable pressure measurement, even under harsh environmental conditions.
The transmitters can be easily mounted directly on the MBV 5000 block test valve or the threaded pressure connection can be used.
The exible pressure transmitter programme covers a 4 – 20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0 – 4 to 0 – 400 bar.
Excellent vibration stability, robust construction, and a high degree of EMC / EMI protection equip the pressure transmitter to meet the most stringent marine requirements.
AI245286497207en-001003
Pressure transmitter, Type MBS 5100 and MBS 5150
Features
Features
• Designed for use in severe maritime environments
• MBS 5150 with integrated pulse-snubber is suitable in marine applications with severe medium inuences like cavitation, liquid hammer or pressure peaks and oers a reliable pressure measurement, even under harsh environmental conditions
• Pressure connection of acid-resistant stainless steel (AISI 316L)
• Pressure ranges in relative (gauge) or absolute from 4 up to 400 bar
• Output signal: 4 – 20 mA
• A wide range of pressure connections
• Fully digitally compensated
• Accuracy 0.3% FS (max)
• UL approved
• Several Marine approvals
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 2
Pulse-snubber
Pressure transmitter, Type MBS 5100 and MBS 5150
Application
Application and media conditions for MBS 5150
Figure 1: MBS 5150
Application
Cavitation, liquid hammer and pressure peaks may occur in hydraulic systems with changes in ow velocity, e.g. fast closing of a valve or pump starts and stops. The problem may occur on the inlet and outlet side, even at rather low operating pressures.
Media condition
Clogging of the nozzle may occur in liquids containing particles. Mounting the transmitter in an upright position minimizes the risk of clogging, because the ow in the nozzle is limited to the start-up period until the dead volume behind the nozzle orice is lled. The media viscosity has only little eect on the response time. Even at a viscosities up to 100 cSt, the response time will not exceed 4 ms.
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 3
Description
Values
Accuracy (incl. non-linearity, hysteresis and repeatability) ≤ ± 0.1% FS (typ.)
≤ ± 0.3% FS (max.)
Non-linearity BFSL (conformity)
≤ ± 0.2% FS
Hysteresis and repeatability
≤ ± 0.1% FS
Response time Liquids with viscosity < 100 cSt
< 4 ms
Air and gases (MBS 5150)
< 35 ms
Overload pressure (static)
6 × FS (max. 1500 bar)
Burst pressure
6 × FS (max. 2000 bar)
Power-up time
< 50ms
Durability, P: 10 – 90% FS
>10 × 106 cycles
Description
Values
Nom. output signal (short-circuit protected)
4 – 20 mA
Supply voltage [UB], polarity protected
9 – 32 V DC
Supply voltage dependency
≤ ± 0.1 % FS / 10 V
Current limitation (linear output signal up to 1.5 × rated range)
22.4 mA
Load [RL] (load connected to 0 V)
RL ≤ (UB- 9 V) / 0.02 A [Ω]
Description
Values
Sensor temperature range
Normal
-40 – 85 °C
Media temperature range
-40 – 85 °C
Ambient temperature range (depending on electrical connection)
-40 – 85 °C
Compensated temperature range
0 – 80 °C
Transport / storage temperature range
-50 – 85 °C
EMC – Emission
EN 61000-6-3
EMC – Immunity
EN 61000-6-2
Insulation resistance
> 100 MΩ at 500 V
Mains frequency test
Based on SEN 361503
Vibration stability
Sinusoidal
15.9 mm-pp, 5 Hz – 25 Hz
IEC 60068-2-6
20 g, 25 Hz – 2 kHz
Random
7.5 grms , 5 Hz – 1 kHz
IEC 60068-2-64
Shock resistance
Shock
500 g / 1 ms
IEC 60068-2-27
Free fall
1 m
IEC 60068-2-32
Enclosure (IP protection fullled together with mating connector)
IP65
Zone 2 applications
(1)
EN60079-0, EN60079-7
Pressure transmitter, Type MBS 5100 and MBS 5150
Product specication
Technical data
Table 1: Performance (EN 60770)
Table 2: Electrical specications
Table 3: Environmental conditions
Table 4: Explosive atmospheres
(1)
(1)
When used in ATEX Zone 2 areas at low temperatures the cable and plug must be protected against impact.
When used in ATEX Zone 2 areas at low temperatures the cable and plug must be protected against impact.
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 4
Description
Values
Electrical connection
EN 175301-803-A plug
Electrical connection, material
Glass lled polyamide PA 6.6
Wetted parts, material
Versions without ange connection
EN 10088-1; 1.4404 (AISI 316L)
Versions with ange connection
Pressure connection
AISI 316L
Plug
Nickel plated brass
Plug gasket
W.no. 10388 Sn5
O-ring for ange
NBR
Enclosure material
Anodized AIMgSiPb
Net weight
0.4 kg
Plug Pg 13.5, EN 175301-803-A
Plug Pg 9 – 11, EN 175301-803-A
93
Danfoss
93Z05.15
93
Danfoss
93Z14.18
Plug type, page 4A6A9
A1
EN 175301-803-A, Pg 11
EN
175301-803-A, Pg 13.5
EN
175301-803-A, Pg 9
Electrical connection, 4 – 20 mA output (2 wire)
Pin 1: + supply Pin 2: ÷ supply Pin 3: Function test 40 – 200 mV Earth: Connected to MBS enclosure
Pin 1: + supply Pin 2: ÷ supply Pin 3: Function test 40 – 200 mV Earth: Connected to MBS enclosure
Pin 1: + supply Pin 2: ÷ supply Pin 3: Function test 40 – 200 mV Earth: Connected to MBS enclosure
Pressure transmitter, Type MBS 5100 and MBS 5150
Table 5: Mechanical characteristics
Dimension
Table 6: Dimension
Electrical connections
Table 7: Electrical connections
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 5
Thread
Flange
Pressure transmitter, Type MBS 5100 and MBS 5150
Mechanical connection
Table 8: Mechanical connection
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 6
MBS 51
1
Gasket / O-ring material
0
No gasket
2
Gasket, NBR -40° – 85°C
4
O-ring, NBR -40° – 85°C
Type Pressure connection
Standard
0 0
C A 0 5
M10 × 1 female
With pulse snubber
5 0
C B 0 4
G ¼ female
C C 0 4
¼ – NPT female
Measuring range D A 0 5
M10 × 1 female with flange
0 – 4.0 bar
1 6
Figures refer to plug and standard PIN configuration – see page 5
0 – 6.0 bar
1 8
0 – 10 bar
2 0 A0
No plug (EN 175301-803-A)
0 – 16 bar
2 2 A1
Plug (EN 175301-803-A), Pg 9
0 – 25 bar
2 4 A6
Plug (EN 175301-803-A), Pg 11
0 – 40 bar
2 6 A9 Plug (EN 175301-803-A), GL Pg 13.5
0 – 60 bar
2 8
0 – 100 bar
3 0
Output signal
0 – 160 bar
3 2 1
4 – 20 mA
0 – 250 bar
3 4
0 – 400 bar
3 6
Pressure reference
Gauge (relative)
1
Absolute
2
Preferred version
Pressure transmitter, Type MBS 5100 and MBS 5150
Ordering
Ordering standards
Non-standard build-up combinations may be selected. However, minimum order quantities may apply. Please contact your local Danfoss oce for further information or request for other versions.
Figure 2: Ordering standards
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 7
File name
Document type
Document topic
Approval authority
BV 06094-F0 BV
Marine - Safety Certicate
BV
RMRS 18.10316.266
Marine - Safety Certicate
RMRS
DNV GL TAA000013G
Marine - Safety Certicate
DNV GL
RINA ELE071320XP-001
Marine - Safety Certicate
RINA
NKK TA18355M
Marine - Safety Certicate
NKK
LR 2010635TA
Marine - Safety Certicate
LR
ABS 15-LD1317840-PDA
Marine - Safety Certicate
ABS
KR DLN 34014-AE001
Marine - Safety Certicate
KR
CCS TJ18T00028
Marine - Safety Certicate
CCS
UL E227388
Explosive - Safety Certicate
Hazardous Locations
UL
UL E31024
Electrical - Safety Certicate
UL
UL E311982
Electrical - Safety Certicate
UL
GOST DK.C.30.018.A 31316
Measuring - Performance Certicate
GOST
EU Declaration Danfoss 060R9400.02
EU Declaration
EMCD/ROHS
Danfoss
060R3160.00
Manufacturers Declaration
China RoHS
Danfoss
BV SMS.W.II-2179-B.0
Marine - Manufacturing Permission
BV
UL E494625
Electrical - Safety Certicate
UL
CSA 1786330
Explosive - Safety Certicate
CSA
ABS 15-LD1309521-PDA
Marine - Safety Certicate
ABS
BV 06094-F0 BV
Marine - Safety Certicate
BV
TSSA CRN.0F18477.5123467890YTN
Pressure - Safety Certicate
CRN
TSSA
Pressure transmitter, Type MBS 5100 and MBS 5150
Certicates, declarations and approvals
The list contains all certicates, declarations, and approvals for this product type. Individual code number may have some or all of these approvals, and certain local approvals may not appear on the list.
Some approvals may change over time. You can check the most current status at danfoss.com or contact your local Danfoss representative if you have any questions.
Valid approvals
Table 9: valid approvals
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 8
Online support
Danfoss oers a wide range of support along with our products, including digital product information, software, mobile apps, and expert guidance. See the possibilities below.
The Danfoss Product Store
The Danfoss Product Store is your one-stop shop for everything product related—no matter where you are in the world or what area of the cooling industry you work in. Get quick access to essential information like product specs, code numbers, technical documentation, certications, accessories, and more. Start browsing at store.danfoss.com.
Find technical documentation
Find the technical documentation you need to get your project up and running. Get direct access to our ocial collection of data sheets, certicates and declarations, manuals and guides, 3D models and drawings, case stories, brochures, and much more.
Start searching now at www.danfoss.com/en/service-and-support/documentation.
Danfoss Learning
Danfoss Learning is a free online learning platform. It features courses and materials specically designed to help engineers, installers, service technicians, and wholesalers better understand the products, applications, industry topics, and trends that will help you do your job better.
Create your Danfoss Learning account for free at www.danfoss.com/en/service-and-support/learning.
Get local information and support
Local Danfoss websites are the main sources for help and information about our company and products. Find product availability, get the latest regional news, or connect with a nearby expert—all in your own language.
Find your local Danfoss website here: www.danfoss.com/en/choose-region.
Spare Parts
Get access to the Danfoss spare parts and service kit catalog right from your smartphone. The app contains a wide range of components for air conditioning and refrigeration applications, such as valves, strainers, pressure switches, and sensors.
Download the Spare Parts app for free at www.danfoss.com/en/service-and-support/downloads.
Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order conrmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, t or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.
© Danfoss | Climate Solutions | 2022.03 AI245286497207en-001003 | 9
Loading...