Data Sheet
Pressure transmitter
Type MBS 3300 and MBS 3350
For high temperature marine applications
The compact high temperature pressure
transmitter is designed for use in almost all
marine applications, and oers a reliable
pressure measurement, even under harsh
environmental conditions.
The exible pressure transmitter programme
covers dierent output signals, absolute or
gauge (relative) versions, measuring ranges
from 0 – 1 to 0 – 600 bar and a wide range of
pressure and electrical connections.
A robust design, an exellent vibration stability,
and a high degree of EMC / EMI protection
equip the pressure transmitter to meet the
most stringent marine requirements.
Features
• Designed for use in severe maritime
environments
• For medium and ambient temperatures up to
125 °C
• All standard output signals:
◦ Ratiometric 10 - 90% of supply
◦ 4 – 20 mA
◦ 0 – 5 V, 1 – 5 V, 1 – 6 V, 0 – 10 V
• Enclosure and wetted parts of AISI 316L
• A wide range of pressure and electrical
connections
• Fully digitally compensated
• For use in ATEX Zone 2 explosive
atmospheres
• UL approved
AI308943247202en-000302
Pressure transmitter, type MBS 3300 and MBS 3350
Applications
Application and media conditions (MBS 3350)
Application
Cavitation, liquid hammer and pressure peaks may occur in liquid lled hydraulic systems with changes in ow
velocity, e.g. fast closing of a valve or pump starts and stops.
The problem may occur on the inlet and outlet side, even at rather low operating pressures.
Media condition
Clogging of the nozzle may occur in liquids containing particles. Mounting the transmitter in an upright position
minimizes the risk of clogging, because the ow in the nozzle is limited to the startup period until the dead volume
behind the nozzle orice is lled.
The media viscosity has only little eect on the response time. Even at a viscosities up to 100 cSt, the response time
will not exceed 4 ms.
© Danfoss | Climate Solutions | 2021.06 AI308943247202en-000302 | 2
Accuracy (incl. non-linearity, hysteresis and repeatability)
≤ ± 0.5% FS (typ.)
Non-linearity BFSL (conformity)
Hysteresis and repeatability
Thermal error band (compensated temperature range)
Response time
Liquids with viscosity < 100 cSt
Overload pressure (static)
Durability, P: 10 – 90% FS
Nom. output signal (short-circuit protected)
10 – 90% of supply voltage
Supply voltage [UB], polarity protected
9 – 32 V DC
(12 / 24 V DC nom.)
9 – 32 V DC
(12 / 24 V DC nom.)
15 – 32 V DC
(12 / 24 V DC nom.)
4.5 – 5.5 V DC
(5 V DC nom.)
Supply – current consumption
Supply voltage dependency
0-5 V: 5.75 V
1-5 V: 5.6 V
1-6 V: 6.75 V
Load [RL] (load connected to 0 V)
Sensor operating temperature (depending on gasket
material)
10 – 90% of supply voltage
0 – 5 V, 1 – 5 V, 1 – 6 V, 0 – 10 V
-40 – 125 °C
Media temperature range
Ambient temperature range (depending on electrical connection)
See Electrical connections
Compensated temperature range
Transport/storage temperature range
Vibration stability
Sinusoidal
IEC 60068-2-6
20 g, 25 Hz – 2 kHz
Enclosure (depending on electrical connection)
See Electrical connections
Pressure transmitter, type MBS 3300 and MBS 3350
Product specication
Technical data
Table 1: Performance (EN 60770)
Table 2: Electrical specications
Table 3: Environmental conditions
Table 4: Explosive atmospheres
(1)
(1)
When used in ATEX Zone 2 areas at low temperatures the cable and plug must be protected against impact.