Danfoss MBS2250 SAE Data sheet

Data Sheet
Heavy-Duty Pressure Transmitter
MBS2250 SAE
Principle of Operation
The pressure transmitter converts measured pressure into a linear temperature compensated output signal that is proportional to the transmitter supply voltage. The output signal varies between 10 and 90% of the supply voltage.
This output signal is well suited for direct connection to an A/D converter provided that the transmitter and the ratiometrically coupled A/D converter use the same voltage reference. Danfoss PLUS+1® and other microcontrollers use ratiometric A/D conversion.
Integrated Pulse Snubber
The heavy duty pressure transmitter with an integrated pulse snubber is specially suited for hydraulic applications where cavitation, liquid hammer, or pressure peaks may occur. The pressure peaks are often short but in extreme excess of the measuring range of the transmitter.
The integrated pulse snubber is principally a nozzle in the passage between the measured medium and the pressure sensitive element of the transmitter
Features
3 pin Delphi Metri-Pack
SAE pressure connection
PLUS+1® Compliant
Resistant to cavitation, liquid hammer, and pressure peaks
Overload pressure up to 6 times measuring range
Durability: >10 million cycles
For use in severe industrial environments:
High vibration stability
IP 67 environmental sealing
Wetted parts and enclosure of acid
resistant steel
CE marked: EMC protected in accordance with EU EMC directive
Temperature compensated, linearized, and laser calibrated
Ratiometric output signal: 10 to 90% of supply voltage
Comprehensive technical literature online at powersolutions.danfoss.com
©
Danfoss | Aug 2016 11005452 | AI00000003en-US0502 | 1
62 [2.44]
9.14 [0.36]
Hex 32 Recommended Torque: 18 to 20 N.m [13.3 to 14.8 lbf.ft]
7/16-20 UNF-2A (SAE - 4 J514) Including Viton O-ring
Metri-Pack ® 150 Series P2S Connector
2380
PR TR
Typ
No
MADE IN DENMARK
1
2
3
2381
Data Sheet
MBS2250 SAE Pressure Transmitter
Dimensions
mm [in]
Specifications
Pressure Connection
Thread Version
SAE 4 7/16-20 UNF-2A (SAE - 4 J514) including Viton O-ring
Pinout and Wiring Information
Pin Function
1 Power supply + 2 Ground 3 Signal output
Electrical Characteristics
Nominal output signal 10 to 90% of V supply Supply voltage V supply (polarity
4.75 to 8 Vdc 5 Vdc (nominal)
protected) Power consumption < 5 mA at 5 Vdc Output impedance < 25Ω Load resistance RL > 5 kΩ at 5 Vdc
Mechanical Characteristics
Materials Wetted parts: DIN 17440 - 1.4404 Enclosure: (AISI 316
l)
Weight 0.2 kg [0.44 lb]
Performance (IEC 770)
Accuracy (at reference conditions)
Non-linearity (best fit straight line)
Hysteresis and repeatability
Thermal zero point shift ≤ ± 0.1% of full-scale/10k (typical); ≤ ±
Thermal sensitivity (span) shift
Response time (liquids) Response time (air and gases)
Overload static and burst pressure
Durability, P: 10 to 90% of
± 0.3% of full-scale (typical); ± 1% of full­scale (maximum)
< ± 0.2% of full-scale
≤ ± 0.1% of full-scale
0.2% of full-scale/10k (maximum) ≤ ± 0.1% of full-scale/10k (typical); ≤ ±
0.2% of full-scale/10k (maximum) < 4 ms; < 35 ms
Maximum overload: up to 6 x FS Maximum burst: up to 6 x FS
> 10 million cycles
Product Part Numbers
Measuring range Danfoss part number
0 to 2.5 bar [36 psi] 10105363 0 to 40 bar [580 psi] 10105364 0 to 160 bar [2320 psi] 10105365 0 to 250 bar [3626 psi] 10105366 0 to 400 bar [5800 psi] 10105367 0 to 500 bar [7250 psi] 10105368 0 to 600 bar [8700 psi] 10105369
Related Product Part Number
Type Danfoss part number
3 pin Delphi Metri-Pack bag assembly
10105567
full-scale
3 pin Delphi Metri-Pack
2 | © Danfoss | Aug 2016 11005452 | AI00000003en-US0502