Danfoss M46 Pumps HC EDC User guide

MAKING MODERN LIVING POSSIBLE
Electrical Installation
M46 Pumps
HC EDC
powersolutions.danfoss.com
Electrical Installation M46 Pumps HC EDC
Revision history Table of revisions
Date Changed Rev
September 2015 Minor layout revision AB
2 L1427804 • Rev ABSeptember 2015
Electrical Installation M46 Pumps HC EDC

Contents

Literature references
Literature references....................................................................................................................................................................... 4
Latest version of technical literature.........................................................................................................................................4
Product overview
Image.................................................................................................................................................................................................... 5
Control options model code........................................................................................................................................................ 5
M46 Pumps.........................................................................................................................................................................................5
System Circuit Diagram..................................................................................................................................................................6
Schematic diagram..........................................................................................................................................................................6
Electrical specifications.................................................................................................................................................................. 7
Electrical installation
Pinout....................................................................................................................................................................................................8
Pin compatibility...............................................................................................................................................................................8
Input/output matrix........................................................................................................................................................................ 8
Mating connector.............................................................................................................................................................................9
L1427804 • Rev ABSeptember 2015 3
Electrical Installation M46 Pumps HC EDC

Literature references

Literature references

References
Literature ID number Title Description
L1001029 Series 40 M46 Pumps Technical Information Complete product electrical and

Latest version of technical literature

Danfoss product literature is online at: http://powersolutions.danfoss.com/literature/
mechanical specifications
4 L1427804 • Rev ABSeptember 2015
P200148
C D E F G J RNH K L SP
M ZT
M P V C
046
Electrical Installation

Product overview

Image

M46 Pumps HC EDC
M46 Pump

Control options model code

M46 Pumps

M46 model code
N—control options
Code Description
HA EDC, high current, 12 volt, Deutsch® connector, 2-pin HB EDC, high current, 24 volt, Deutsch® connector, 2-pin
M46 pumps are designed for medium power applications with maximum loads of 345 bar [5000 psi]. These pumps can be combined with other products in a system to transfer and control hydraulic power.
M46 pumps provide an infinitely variable speed range between zero and maximum in both forward and reverse modes of operation.
M46 pumps are compact, high power density units. All models use the parallel axial piston / slipper concept in conjunction with a tiltable swashplate to vary the pump’s displacement. Reversing the angle of the swashplate reverses the flow of fluid from the pump, reversing the direction of rotation of the motor output.
M46 pumps may include an integral charge pump to provide system replenishing and cooling fluid flow, as well as servo control fluid flow. M46 pumps feature a range of auxiliary mounting pads to accept auxiliary hydraulic pumps for use in complementary hydraulic systems.
M46 pumps offer proportional controls with either manual, hydraulic, or electronic actuation. An electric three-position control is also available.
L1427804 • Rev ABSeptember 2015 5
Input shaft
Suction flow
Servo pressure
High pressure
Case flow
Charge pressure
Output shaft
Cylinder block assembly
Filter
Charge
pump
Reservoir
Fixed displacement motor
Cylinder
block
assembly
Heat exchanger
Check valves w/ high pressure relief valve
Variable displacement pump
Heat exchanger bypass
Charge relief valve
Displacement control valve
Control handle
Bypass
valve
Loop flushing
module
P100586
P109759
C2
C1
M4
M5
L2
L1
S M2
B
A
M1
D
E
flow out B
Electrical Installation
Product overview

System Circuit Diagram

M46 Pumps HC EDC

Schematic diagram

6 L1427804 • Rev ABSeptember 2015
P003479E
"0"
-b -a
ba
100 %
100 %
Displacement
Current mA
Electrical Installation M46 Pumps HC EDC
Product overview

Electrical specifications

Pump displacement vs. control current
Solenoid electrical specifications
Voltage
Maximum current
Coil resistance @ 20 °C [70 °F]
Coil resistance @ 80 °C [176 °F]
PWM Range
PWM Frequency (preferred)**
Inductance
*
PWM signal required for optimum control performance.
12V 24V
1800 mA 920 mA
3.66 Ω 14.20 Ω
4.52 Ω 17.52 Ω
70-200 Hz
100 Hz
33 mH 140 mH
L1427804 • Rev ABSeptember 2015 7
1 2
P003480
P003 191

Electrical Installation

Electrical installation

Pinout

Pin compatibility

M46 Pumps HC EDC
Pin location
Pinout
Pin Description
1 PWM signal/voltage input 2 Ground
PLUS+1® module pin type
Pin Function
1, 2 PWMOUT/DOUT/PVG Power supply 1, 2 PWMOUT/DOUT/PVGOUT 1, 2 Power ground -

Input/output matrix

EDC/C1 and C2 location
8 L1427804 • Rev ABSeptember 2015
Electrical Installation M46 Pumps HC EDC
Electrical installation
Pump output flow direction versus control signal
Shaft rotation CW CCW
*

Mating connector

Coil energized
Port A in out out in Port B out in in out Servo port pressurized M5 M4 M5 M4
*
For coil location see installation drawings in the Series 40 M46 Pumps Technical Information, L1001029..
Parts list
Description Quantity Ordering number
Mating connector 1 Deutsch® DT06-2S Wedge lock 1 Deutsch® W2S Socket contact (16 and 18 AWG) 2 Deutsch® 0462-201-16141 Danfoss mating connector kit 1 K29657
C2 C1 C2 C1
L1427804 • Rev ABSeptember 2015 9
Electrical Installation M46 Pumps HC EDC
10 L1427804 • Rev ABSeptember 2015
Electrical Installation M46 Pumps HC EDC
L1427804 • Rev ABSeptember 2015 11
Danfoss Power Solutions GmbH & Co. OHG
Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0
Danfoss Power Solutions ApS
Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222
Danfoss Power Solutions (US) Company
2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000
Danfoss Power Solutions Trading (Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 3418 5200
Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmueller­inverter.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
L1427804 • Rev AB • September 2015 www.danfoss.com
Local address:
©
Danfoss A/S, 2015
Loading...