Danfoss M19 Technical Information

Cartridge Valves Coils Technical Information
M19
SPECIFICATIONS
Duty cycle: 100% at 115% of rated voltage at 40°C [104° F]
Magnet wire insulation: (200° C)
Ambient temperature range: -20° to 40° C [-4° to 104° F]
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130° C [266° F] above ambient temperature
Weight: 0.37 kg [0.82 lb]
AC Coils require external rectier
ELECTRICAL SPECIFICATIONS
TERMINALS
ISO 4400 (DIN 43650) Code DN
Voltage 12 VDC 24 VDC 110 VAC 220 VAC
Resistance (Ohms) @ 20° C [68F]
Current draw (A) at 25° C [68° F]
4.4 17 287 1190
2.76 1.38 0.337 0.163
Voltage (V) Power (W) Part Number
12VDC 33 M19-12D-33W-DN
24VDC 33 M19-24D-33W-DN
110VAC* 33 M19-110RA-33W-DN
220VAC* 33 M19-220RA-33W-DN
* External rectier needed
BC332376631124en-000101 • February 2020
CL - 25
Cartridge Valves Coils Technical Information
M19
LEAD WIRES CODE FL
DEUTSCH CODE DE
Voltage (V) Power (W) Part Number
12VDC 33 M19-12D-33W-AJ
24VDC 33 M19-24D-33W-AJ
Voltage (V) Power (W) Part Number
12VDC 33 M19-12D-33W-DE
24VDC 33 M19-24D-33W-DE
DEUTSCH WITH DIODE CODE DED
Pin 1
BC332376631124en-000101 • February 2020
Voltage (V) Power (W) Part Number
12VDC 33 M19-12D-33W-DED
24VDC 33 M19-24D-33W-DED
Pin 2
CL - 26
Loading...
+ 1 hidden pages