Danfoss LFB12 Data sheet

Data Sheet
Loop Flushing Block
LFB12
The Loop Flushing Block is designed to help sustain high quality working fluid in a hydraulic transmission circuit. By allowing oil to drain from the power transmission loop to other oil treatment components, the LFB12 assists in the process of removing contamination and cooling oil.
Ports A and B are connected to the work ports of the main transmission circuit. Port DR is connected to the transmission case drain return line. Ideally, the return line would flush through the motor case before returning to the reservoir.
The low pressure side of the circuit is sent to the relief valve, which is then drained out of the transmission loop. The amount of flow drained from the loop can be determined by adjusting the relief valve setting and installing an optional orifice. With a wide range of relief valve settings and orifice sizes, the LFB12 can be fine-tuned to match the machine’s optimal drain rate.
Features
Max pressure: 350 bar [5075 psi]
Rated flow: see performance chart
Provides loop flushing capabilities at various flows for a wide range of applications
Optimal flow design
Low pressure differential
Steel body for high pressure applications
Simple design for ease of serviceability
Compact profile for minimal space requirements
Overall size: 156.7 mm x 150 mm x 40 mm
Open and closed center spools
Comprehensive technical literature is online at www.danfoss.com
©
Danfoss | September 2020 AI354779216257en-000101 | 1
0 2 4 6 8 10 12
0
50
100
150
200
250
0
5
10
15
20
0 10 20 30 40 50
Charge pressure minus relief setting
Flow
gpm
lpm
barpsi
None
2. 5mm
3. 0mm
3. 5mm
4. 0mm
4. 5mm 5. 0mm
Data Sheet
Loop flushing block LFB12
Schematics
Closed center spool option
Performance
Pressure rise per orifice option
Open center spool option
2 | © Danfoss | September 2020 AI354779216257en-000101