Danfoss KE04202 Installation guide

Unit Specification
KE04202 Valve Drive Amplifier
3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: (763) 509-2084 Telefax: (763) 559-0108
GENERAL DESCRIPTION
The device is a free–standing amplifier mounted on 4 standoffs. Voltage from a sensor potentiometer, through the amplifier, produces current to drive electrohydraulic actuators. Connections to the amplifier are via screw terminals. An external switch can change gain settings by shorting between two terminals.
ISSUE: 2 DATE: September 1996
DIMENSIONS
6,35
(0.25)
76,20 (3.00)
57,15 (2.25)
9,65
(0.38)
5,33 (0.21) INSIDE DIA.
12,70 (0.50)
Dimensions of the KE04202 in Millimeters (Inches).
114,30 (4.50)
101,60 (4.00)
CONNECTION DIAGRAM
1
2
3
4
KE04201
VALVE DRIVE
AMPLIFIER
POLARITY OF BATTERY CONNECTIONS MAY BE REVERSED TO CHANGE ACTION OUTPUT VERSUS SENSOR INPUT
GAIN SWITCH IS OPTIONAL. JUMPERS MAY BE USED IN PLACE OF SWITCH
1647 1648
5
6
7
8
9
10
-
+
POTENTIOMETER
ROTARY POSITION
MED LOW HIGH
NO CONNECTION
OUTPUT TO 30 LOAD
+
BATTERY
-
ACX104C
SENSOR
GAIN SWITCH
OUTPUT CHARACTERISTICS
SUPPLY VOLTAGE
24 Vdc (22 to 30 Volts)
TURN ON VOLTAGE
48% of supply
% MAXIMUM
OUTPUT VOLTAGE
MAXIMUM OUTPUT CURRENT
100 mA nominal
.
© Danfoss, 2013-09 K15299 UNIT SPEC 1
100
90 80 70
HIGH GAIN
MED GAIN
LOW GAIN
60 50 40 30 20 10
10 20 30 40 50 60 70 80 90 100
% SUPPLY VOLTAGE
1649A
.
.
Loading...