Danfoss KE04110 Installation guide

Danfoss KE04110 Installation guide

Unit Specification

KE04110

Valve Drive Amplifier

3500 Annapolis Lane North, Minneapolis, MN 55447

 

 

Telephone: (763) 509-2084 Telefax: (763) 559-0108

ISSUE: 2

DATE: September 1996

GENERAL DESCRIPTION

The device is a free–standing amplifier mounted on 4 standoffs. Current or voltage signal from a transducer/controller, through the amplifier, produces current to drive electrohydraulic actuators. Connections to the amplifier are via screw terminals.

DIMENSIONS

CONNECTION DIAGRAM

 

6,35

114,30

(4.50)

1

 

 

101,60 (4.00)

 

 

(0.25)

 

 

 

 

 

 

2

 

 

 

 

CURRENT

3

 

 

 

 

SOURCE

 

 

 

 

 

 

4

 

A EDC B

 

 

 

 

2

76,20

 

 

5

 

 

 

DIRECT OUTPUT

VALVE COIL

(3.00)

 

 

 

 

 

 

 

 

57,15

 

KE04110

6

 

 

 

 

 

 

(2.25)

 

VALVE

7

 

 

 

 

24 V

 

 

 

DRIVE

 

 

 

 

 

 

 

 

AMPLIFIER

8

 

 

 

 

 

 

 

 

 

 

9

SIGNAL COMMON

 

9,65

 

 

 

4 TO 20 mA SIGNAL

 

(0.38)

 

 

10

 

 

 

 

 

 

 

 

 

1

TRANSDUCER/

 

 

 

 

 

 

5,33 (0.21) INSIDE DIA.

 

 

 

CONTROLLER

1 INPUT IMPEDANCE IS 240 OHMS

2 DIRECT OUTPUT: 200 mA AT 10 VOLTS MAXIMUM

12,70

(0.50)

1647

1657

Dimensions of the KE04110 in Millimeters (Inches).

OUTPUT CHARACTERISTICS

SUPPLY VOLTAGE

24 Vdc

INPUT IMPEDANCE 240 ohm

START CURRENT

4 mA nominal (1 Volt)

FULL STROKE CURRENT

20 mA (4.8 Volt)

OUTPUT CURRENT

100 mA into a 25 ohm load

<![if ! IE]>

<![endif]>OUTPUT -%

100

90

80

70

60

50

40

30

20

10

0

 

2

 

4

 

6

 

8

 

10

 

12

 

14

 

16

 

18

 

20

INPUT CURRENT

 

 

 

 

1651A

 

 

 

 

 

 

 

 

 

 

 

 

 

K14510 UNIT SPEC

K14510 UNIT SPEC

s (US) Company.

1

 

 

© Danfoss, 2013-09

u

 

 

 

 

 

 

 

Loading...