Danfoss JS7000 Electrical Installation Instructions

Page 1
Electrical Installation
Joystick
JS7000 Analog and CAN Output
powersolutions.danfoss.com
Page 2
Revision history Table of revisions
Date Changed Rev
July 2014 Converted to Danfoss layout CA
May 2012 Addition of CAN+ BA
June 2011 First edition AA
Electrical Installation
JS7000 Analog and CAN Output
2 | © Danfoss | May 2017 L1105361 | 0201
Page 3
Literature references
JS7000 Analog and CAN Output literature references....................................................................................................... 4
Latest version of technical literature.........................................................................................................................................4
Product overview
Product image................................................................................................................................................................................... 5
Theory of operation.........................................................................................................................................................................5
Electrical specifications.................................................................................................................................................................. 6
Electrical installation
Pinout....................................................................................................................................................................................................7
Digital and proportional...........................................................................................................................................................7
Digital outputs rocker options............................................................................................................................................... 7
Proportional analog pinouts...................................................................................................................................................7
Pinout connections examples................................................................................................................................................8
One 18 pin connector..................................................................................................................................................................... 8
Mating connector.............................................................................................................................................................................9
Electrical Installation
JS7000 Analog and CAN Output
Contents
©
Danfoss | May 2017 L1105361 | 0201 | 3
Page 4
JS7000 Analog and CAN Output literature references
Literature title Description Literature number
JS7000 Joystick Technical Information Complete product electrical and
mechanical specifications
L1125277
JS7000 Function Blocks User Manuals X Compliant function block set-up
information
L1117525 XP3P4 L1118640 XP3 L1118766 XP3P5 L1119135 XY L1119283 XYP3P4 L1120472 XYP3 L1120568 Y L1123424 XYP3P5 L1123537 YP3 L1124042 YP3P5 L1124120 YP3P4 L1124191
Latest version of technical literature
Danfoss product literature is online at: http://powersolutions.danfoss.com/literature/
Electrical Installation
JS7000 Analog and CAN Output
Literature references
4 | © Danfoss | May 2017 L1105361 | 0201
Page 5
Product image
JS7000 Analog and CAN Output
Theory of operation
Danfoss JS7000 joysticks are general purpose mobile machine control joysticks. They are available in a Y and an XY axis configuration and support four grip options.
JS7000 joysticks support two electrical output options: Analog and Controller Area Network (CAN). JS7000 joysticks support handle position measurement technology option: Hall effect. With two
independent sensors per axis measure handle position. Grip analog and switch signals are hard-wired to the joystick base.
Three JS7000 PLUS+1® Compliant HWD files are available. One supports joysticks having analog outputs a second supports joysticks that have the CAN output option, and a third supports CAN+ output option.
The compliant function block algorithm uses input voltage to determine handle position, direction and null position.
The compliant function block algorithm uses one sensor input per axis to determine handle direction and null position. The algorithm does not compare the dual sensor signals.
The compliant function block requires that the JS7000 joystick base be supplied with 5 Vdc regulated sensor power provided by a PLUS+1® control device.
Electrical Installation
JS7000 Analog and CAN Output
Product overview
©
Danfoss | May 2017 L1105361 | 0201 | 5
Page 6
Electrical specifications
Electrical
Sensor type Hall Effect with redundant sensors Resolution Infinite Supply voltage Analog 5 ± 0.5 Vdc
CAN with redundant analog outputs
9 to 60 Vdc
CAN+ 9 to 60 Vdc
Output Analog 0.5 to 4.5 Vdc
Minimum voltage 10% ± 4% Vs Center voltage 50% ± 2% Vs Maximum voltage 90% ± 4% Vs CAN 2.0 B, J1939 and CANopen protocols CAN+ 2.0 B, J1939
Base maximum current consumption
Analog 45 mA CAN 120 mA at 9 V CAN+ 100 mA at 9 V (without LEDs or
sensor power)
Base maximum survival supply voltage
Analog 30 Vdc CAN 68 Vdc CAN+ 68 Vdc
Electrical Installation
JS7000 Analog and CAN Output
Product overview
6 | © Danfoss | May 2017 L1105361 | 0201
Page 7
Pinout
Digital and proportional
Digital includes trigger, push-button, and rocker. Proportional includes roller and slider.
Grip trigger switch
Grip backside
Grip faceplate
Digital outputs rocker options
Grip faceplate example Grip position 3 example
Proportional analog pinouts
Proportional analog pinouts for proportional roller with redundant output (HR option)
Position
1 and/or 2 2 and 3 1 and 2 with 3
HR HR PN, S2, S3 HR
Roller Roller Roller/slider Roller P1 P2 P2 P3 P1 P2 P3
Primary output pins
3 4 4 5 3 4 5
Redundant output pins
5 6 6 3
* *
6
*
Not applicable
Electrical Installation
JS7000 Analog and CAN Output
Electrical installation
©
Danfoss | May 2017 L1105361 | 0201 | 7
Page 8
Pinout connections examples
Analog grip pinout connections example CAN and CAN+ minimum pinout
connections example
Pin number
Signal number Description Pin
number
Signal number
7 Digital1 Faceplate push-button 1 1 Battery Ground 12 Digital6 Back side push-button 6 2 Battery Power 14 Digital8 Trigger switch 3 CAN Hi 3 Proportional1 Face plate proportional1PN, S2, S3 4 CAN Lo
5 Proportional3 Back side proportional 3 PN, S2, S3 5 CAN Shield
One 18 pin connector
18 pin DEUTSCH connector (DT16-18SB-K004)
18
6
13
1
P200065
Pinouts
Analog CAN CAN+ Pin
number
Signal name Pin
number
Signal name Pin
number
Signal name
1 Battery Ground 1 Battery Ground 1 Battery Ground 2 +5V 2 Battery Power 2 Battery Power 3 Proportional1
*
3 CAN Hi 3 CAN Hi
4 Proportional2
*
4 CAN Lo 4 CAN Lo
5 Proportional3
*
5 CAN Shield 5 CAN Shield
6 Proportional4
*
6 Not Connected 6 Digital Input 7 7 Digital1 7 Reference Ground 7 Sensor Ground 8 Digital2 8 Reference +5V 8 Sensor Power +5V 9 Digital3 9 Not Connected 9 Analog/Digital Input 1 10 Digital4 10 Not Connected 10 Analog/Digital Input 2 11 Digital5 11 Not Connected 11 Analog/Digital Input 3 12 Digital6 12 Not Connected 12 Analog/Digital Input 4 13 Digital7 13 Not Connected 13 Digital Input 1 14 Digital8 14 Not Connected 14 Digital Input 2 15 Proportional Y Axis 1 15 Proportional Y Axis 1 15 Digital Input 3 16 Proportional X Axis 1 16 Proportional X Axis 1 16 Digital Input 4 17 Proportional Y Axis 2 17 Proportional Y Axis 2 17 Digital Input 5 18 Proportional X Axis 2 18 Proportional X Axis 2 18 Digital Input 6
*
Reference Proportional analog pinouts on page 7 for proportional roller with redundant output (HR option)
Electrical Installation
JS7000 Analog and CAN Output
Electrical installation
8 | © Danfoss | May 2017 L1105361 | 0201
Page 9
Mating connector
Mating connector bag assembly
Description Danfoss ordering number
Mating connector bag assembly 11012648
Mating connector bag assembly contents
Description Quantity
Connector DEUTSCH, DT16-18SB-K004
1
Terminals DEUTSCH, 0462-201-1631
18
The mating connector bag assembly contains loose parts you must assemble.
Danfoss mating connector
Description Quantity Danfoss ordering number
Mating connector with 400 mm (15.75 in) wire harness
1
11012646
The Danfoss mating connector with wire harness features a fully assembled connector with an unterminated wire harness.
Electrical Installation
JS7000 Analog and CAN Output
Electrical installation
©
Danfoss | May 2017 L1105361 | 0201 | 9
Page 10
Electrical Installation
JS7000 Analog and CAN Output
10 | © Danfoss | May 2017 L1105361 | 0201
Page 11
Electrical Installation
JS7000 Analog and CAN Output
©
Danfoss | May 2017 L1105361 | 0201 | 11
Page 12
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles.
We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster.
Danfoss – Your Strongest Partner in Mobile Hydraulics.
Go to www.powersolutions.danfoss.com for further product information.
Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components.
Please contact the Danfoss Power Solution representative nearest you.
Local address:
Danfoss Power Solutions GmbH & Co. OHG
Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0
Danfoss Power Solutions ApS
Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222
Danfoss Power Solutions (US) Company
2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000
Danfoss Power Solutions Trading (Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
©
Danfoss | May 2017 L1105361 | 0201
Products we offer:
Bent Axis Motors
Closed Circuit Axial Piston Pumps and Motors
Displays
Electrohydraulic Power Steering
Electrohydraulics
Hydraulic Power Steering
Integrated Systems
Joysticks and Control Handles
Microcontrollers and Software
Open Circuit Axial Piston Pumps
Orbital Motors
PLUS+1® GUIDE
Proportional Valves
Sensors
Steering
Transit Mixer Drives
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com
Loading...