Data Sheet
PLUS+1® Expansion Module
IX024-010
Mobile Machine Management
IX024-010 is an element of the flexible, powerful and
expandable PLUS+1® family of mobile machine
management products. Expansion modules provide
cost-effective additional I/O to mobile machine
control systems.
Product Highlights
Expansion modules are associated with a PLUS+1
controller. PLUS+1® GUIDE (Graphical User Integrated
Development Environment) applications running in
the controller read inputs from and write outputs to
expansion module pins as if the pins are physically
located on the controller. Pin properties are
configured in the controller’s GUIDE application.
®
PLUS+1® compliance eliminates need for the system
designer to write CAN transmit and receive messages
in both the controller and associated expansion
modules.
Application Development
Users configure expansion modules using PLUS+1
GUIDE. This Microsoft® Windows®-based
development environment features a user-friendly,
field proven, icon-based graphical programming tool,
application downloader, and service/ diagnostic tool.
Features
• 24 pin: (2) individually keyed DEUTSCH
DTM 12 pin connectors
®
• 18 inputs
‒
• 10 to 36 Vdc power supply, monitored
internally
• Power supply for external sensors rated
at 5 Vdc to 200 mA and regulated
internally
• 3 mounting alternatives: stack, end, or
side
‒
• CE compliant
(7) universal (DIN/AIN/FreqIN) that
the user can define as either:
Analog: with configurable ranges 0 to
5.25 Vdc (with over range protection) or
0 to 36 Vdc; Digital: pull up (5 Vdc), pull
down (0 Vdc) or pull to center (2.5 Vdc);
Frequency (timing): 1 Hz to 10 kHz
(4) analog (AIN/Temp/Rheo) 0 to 5 Vdc
or
0 to 10,000 ohm rheostat
(6) digital (DIN) configurable as pull
‒
up (5 Vdc), pull down (0 Vdc)
(1) fixed-range analog (AIN/CAN
‒
shield) 0 to 5.25 Vdc or CAN shield pin
Comprehensive technical literature is
online at www.danfoss.com
©
Danfoss | September 2018 AI00000010en-001301 | 1

IX024-010 Dimensions and Pin Assignments
mm [in]
114.4
Connector 2 'B' key (black), Connector 1 'A' key (gray)
1 6 1
C1C2
6
35.0
158.2
144.5
25.2
97.0
142.0
2 1
51.6
47.1
C1
C
C2
Caution
This device is not field serviceable. Opening the device housing
will void the warranty.
Specifications
12
7
12
7
Use care when wiring mating connector. Pinouts are for device
pins.
Pin Controller function Pin Controller function
C2-P1 DIN C1-P1 Power ground C2-P2 DIN/AIN/FreqIN C1-P2 Power supply +
C2-P3 DIN/AIN/FreqIN C1-P3 CAN +
C2-P4 DIN/AIN/FreqIN C1-P4 CAN C2-P5 DIN/AIN/FreqIN C1-P5 AIN/CAN shield
C2-P6 DIN/AIN/FreqIN C1-P6 5 Vdc sensor power +
C2-P7 DIN/AIN/FreqIN C1-P7 Sensor power ground C2-P8 DIN/AIN/FreqIN C1-P8 DIN
C2-P9 AIN/Temp/Rheo C1-P9 DIN
C2-P10 AIN/Temp/Rheo C1-P10 DIN
C2-P11 AIN/Temp/Rheo C1-P11 DIN
C2-P12 AIN/Temp/Rheo C1-P12 DIN
Ordering information
Product part number
IX024-010 10100998
Supply voltage 10 to 36 Vdc
Operating temperature
-40°C to 70°C [-40°F to 158°F]
(ambient)
Storage temperature -40°C to 85°C [-40°F to 185°F]
IP rating (with mating connector
IP 67
Related products part numbers
CG150 CAN/USB Gateway 11153051
DEUTSCH mating connector bag
assembly
PLUS+1® GUIDE Professional 11179523
10102023
(16 to 20 AWG)
10100945
(20 to 24 AWG)
attached)
EMI/ RFI rating 100 V/m
Weight 0.40 kg [0.88 lb]
Vibration IEC 60068-2-64
Shock IEC 60068-2-27 test Ea
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
4 | © Danfoss | September 2018 AI00000010en-001301