Danfoss iSave 50, iSave 70 Service guide

Instruction
Instruction
Recommended service intervals
iSave Energy Recovery Device
iSave 50 - 70
for APP 0.6-1.0 / APP 1.5-3.5 /
APP (W) 5.1-10.2 / APP 11-13 / APP 16-22
hpp.danfoss.com
ro-solutions.com
Instruction | Recommended service intervals for iSave 50 - 70 ERDs
Table of Contents
Table of Contents
1. General information.....................................................................2
2. Design/features ........................................................................3
3. Service intervals ........................................................................3
3.1 iSave 50 - 70 ............................................................................3
1. General information This guideline provides information on the recommended service intervals. The recommen­dation is based upon good engineering practice and on experience gained from operation even under extreme conditions.
The recommendation is for guidance only.
2
AX290138222999en- 000101 | 12 .2018
Instruction | Recommended service intervals for iSave 50 - 70 ERDs
2. Design/features Danfoss iSave ERD is designed for long operation and low maintenance and life cycle costs.
Provided that the ERD has been running according to the Danfoss specifications, Danfoss guarantees one year service-free operation, however, max. 18 months from date of production. After one year of operation it is recommended to inspect the iSave and replace worn parts, if any.
3. Service intervals
3.1 iSave 50 - 70
Description
Too l kit)
Screw and seal kit 32,000 hours 26,000 hours
Shaft seal kit 32,000 hours 26,000 hours
Coupling kit 56,000 hours 56,000 hours
Port plate kit PE iSave 50 32,000 hours 26,000 hours
Port plate kit PE iSave 70 32,000 hours 26,000 hours
Vane kit (8 pcs)
Valve plate kit, Pressure exchanger 32,000 hours 26,000 hours
Rotor elements and sealing plates kit 32,000 hours 26,000 hours
1)
For detailed information on parts, see
1)
Service guide 521B1428 Parts list.
If the Danfoss recommendations concerning system-design (see our data sheet) are not followed, the service life of the iSave ERD might be affected.
The recommended service intervals on the differ­ent parts in the iSave ERD appears from the table below:
Service interval Service interval (2nd, 3rd)
AX290138222999en- 000101 | 12 .2018
3
Danfoss A/S
High Pressure Pumps Nordborgvej 81 DK-6430 Nordborg Denmark
© Danfoss | DCS (im | 2018.12