Danfoss IOX018-130 Data sheet

Danfoss IOX018-130 Data sheet

Data Sheet

PLUS+1® Expansion Module

IOX018-130 High Current

Mobile machine management

IOX018-130 High Current Expansion Module is an element of the flexible, powerful and expandable PLUS+1® family of mobile machine management products. Expansion modules provide cost-effective additional I/O to mobile machine control systems.

Product highlights

The PLUS+1® High Current expansion module employs a 32 bit Cortex-M3 Processor, providing the controller with extremely fast single cycle processing speed. It features high current capabilities for your machine control.

PLUS+1® compliance eliminates need for the system designer to write CAN transmit and receive messages in both the controller and associated expansion modules.

Application development

Users configure expansion modules using PLUS+1® GUIDE. This Microsoft® Windows®-based development environment features a user-friendly, field proven, icon-based graphical programming tool, application downloader, and service/ diagnostic tool.

Features

User-programmable with PLUS+1® GUIDE (Graphical User Integrated Development Environment)

18 pins: (2) DEUTSCH connectors (DT and DTP), (2) 6 mm studs

12 bit analog-to-digital converter

ARM 32 bit Cortex-M3 running at 120 MHz

Comprehensive technical literature is online at www.danfoss.com

© Danfoss | March 2019

AI297367135765en-000102 | 1

Data Sheet

IOX018-130 High Current Expansion Module

4inputs

(2) Universal (DIN/AIN/FreqIN/Rheo) Digital: Pull up (5 VDC), pull down (0 VDC) or pull to center (2.5 VDC)

Analog: 0 to 0.375 VDC, 0 to 5.25 VDC, or 0 to 36 VDC

Frequency (timing): 1 Hz to 10 kHz Resistance: 0 to 10,000 ohm

(1) Digital/Analog (DIN/AIN) that is userdefined as either:

Digital: Pull up (5 VDC), pull down (0 VDC) or pull to center (2.5 VDC) Analog: 0 to 5.25 VDC or 0 to 36 VDC

(1) Digital/Analog/CAN shield (DIN/AIN/CAN shield) that is userdefined as either:

Digital: Pull up (5 VDC), pull down (0 VDC) or pull to center (2.5 VDC) Analog: 0 to 5.25 VDC or 0 to 36 VDC CAN shield

Characteristics

8 outputs

(4) Universal (PWMOUT/DOUT/PVGOUT) that are user-defined as either:

Digital: 15 A, configurable as source or sink

PWM: 15 A (33 to 4000 Hz or 20 kHz), configurable as open or closed loop with current control

(4) Universal (PWMOUT/DOUT/PVGOUT) that are user-defined as either:

Digital: 25 A, configurable as source or sink

PWM: 25 A (33 to 4000 Hz or 20 kHz), configurable as open or closed loop with current control

Supply voltage

9 to 36 VDC

Operating temperature (ambient)

– 40°C to 70°C [– 40°F to 158°F]

Storage temperature

– 40°C to 85°C [– 40°F to 185°F]

Programming temperature

– 40°C to 70°C [– 40°F to 158°F]

IP rating (with mating connector attached)

IP 67

EMI/RFI rating

100 V/M

Weight

1.29 kg [2.85 lb]

Vibration

IEC 60068-2-64

Shock

IEC 60068-2-27 test Ea

Maximum current, sourcing

120 A

Maximum current, sinking

120 A

 

 