Description
Application
.30 |
m |
|
|
Max |
|
Metal / Steel
Danfoss Icon™ Repeater is used to extend the range between thermostats and master controller or to troubleshoot in systems with objects impeding the signal. The repeater can be plugged directly into a 230 V power outlet.
Max . 30
m
Ordering |
|
|
|
Product |
Code number |
||
|
|||
|
|
|
|
|
Danfoss Icon™ Repeater |
088U1102 |
|
|
|
|
VDMCD102 |
© Danfoss | FEC | 2018.12 | 1 |
Tecnical data
Drawings
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Purpose of control |
Extending the range of the radio signal. |
|
|||
|
|
|
|||
Ambient temperature range, continious use |
0 °C to +40 °C |
|
|||
|
|
|
|||
Frequency |
868,4-869,85 MHz |
|
|||
|
|
|
|||
Encapsulation (IP Class) |
IP 20 |
|
|||
|
|
|
|||
Conformity declared acc. to following directives |
RED, RoHS, WEEE |
|
|||
|
|
|
|||
Protection class Radio |
Class III |
|
|||
|
|
|
|||
Supply voltage |
230 VAC 50 Hz |
|
|||
|
|
|
|||
Temperature for the ball pressure test |
75 °C |
|
|||
|
|
|
|||
Control polution degree |
Degree 2, normal household environment |
|
|||
|
|
|
|||
Software class |
Class A |
|
|||
|
|
|
|||
Rated impulse voltage |
4 kV |
|
|||
|
|
|
|||
Operating time |
Permanently connected |
|
|||
|
|
|
|||
Temperature range, storage and transportation |
-20 °C to +65 °C |
|
|||
|
|
|
|||
Dispossal instructions |
The product must be disposed as electronic |
|
|||
|