Danfoss Icon Programmerbar Data sheet

Danfoss Icon Programmerbar Data sheet

Data Sheet

Danfoss Icon™ Programmable

Room Thermostats, 230 V

Description

Ordering

Accessories

Danfoss Icon™ Programmable 088U1021

Danfoss Icon™ is a range of flush and surface mounted room thermostats for hydronic floor heating applications.

Danfoss Icon™ Programmable is mains powered and can be used as a stand-alone thermostat or in combination with wiring center 088H001600.

The thermostat uses a triac output and can control up to 5 thermal actuators.

The user can choose between 7 pre-defined heating schedules. A schedule can be temporarily overrided by using the three mode keys.

The thermostat can also operate without scheduling (constant room temperature setpoint).

The thermostat uses forecast (adaptive learning).

The thermostat uses a “touch on glass” interface with a shine through display. The display is “OFF” in normal operation.

Danfoss Icon™ Programmable 088U1025

Features

Accurate PWM-control

Shine through display with mode keys

7 pre-defined schedules and forecast

Range limitation via user menu

Neutral design and simple user interface

Frost protection setting

Can be used with 230 V NC or NO actuators

Can be optimized for different heat sources via service menu

Valve exercise feature

Can be used in systems with cooling

Has input for global setback

Can be used with floor sensor (optional)

Very high UV-resistance

Product

Version

Size

For junction box

Code no.

 

 

 

 

 

Danfoss Icon™ Programmable

In-wall

86 x 86 mm

Square, 70x70 mm

088U1021

 

 

 

 

 

Danfoss Icon™ Programmable

On-wall

86 x 86 mm

N.A.

088U1025

 

 

 

 

 

Product

Description

Code no.

 

 

 

Danfoss FH-WC, 230V

Wiring center, 8 channels, up to 16 outputs

088H001600

 

 

 

Danfoss Icon™ Floor Sensor

47 kΩ, 3 m, IP 67

088U1110

 

 

 

VDSUD212

© Danfoss | FEC | 2019.03 | 1

Data Sheet

Danfoss Icon™ Programmable Room Thermostats, 230 V

 

Technical specifications

 

 

 

 

Type

Electronic thermostat with touch user interface

 

 

 

 

 

 

User interface

Capacitive touch and shine through display

 

 

 

 

 

User interface features

Heating icon, arrow up/down, confirm key, back

 

key, Home, Away, Night, Settings

 

 

 

 

 

 

 

Display type

Hybrid: red single LED’s and custom segment

 

 

 

 

 

Display features

Switches OFF after 10 sec. with no interaction

 

 

 

 

 

 

Yes, std. Gregorian calendar.

 

Real time clock

8 hrs. running reserve (new product) down to 1.5

 

 

hrs. running reserve in year 10 after installation.

 

 

 

 

 

Automatic daylight saving time

Standard, can be turned off

 

 

 

 

 

Heating schedules

7 x pre-defined schedules (P0-P6)

 

5/2 days (weekdays and weekends)

 

 

 

 

 

 

 

Temperature setting range

5 °C to 35 °C (frost protection setting = 5 °C)

 

 

 

 

 

 

Ambient temperature, storage

-20 °C to +60 °C

 

 

 

 

 

 

 

Ambient temperature, used in application

0 to +40 °C

 

 

 

 

 

 

Controller, type

Adjustable Pulse Width Modulation

 

 

 

 

 

Change over, cooling

Yes, via 230 V input terminal

 

 

 

 

 

Global setback/Away

Yes, via 230 V input terminal

 

 

 

 

 

Max. continuous load (output)

< 50 mA /10 W (= 5 pcs. Danfoss TWA actuators)

 

 

 

 

 

 

Max. inrush current (actuator)

3 A ≤ 100 ms

 

 

 

 

 

 

 

Power consumption

0,2 W

 

 

 

 

 

 

Power supply (excl. actuators)

220-240 V, 50/60 Hz

 

 

 

 

 

 

Sensor, room

NTC 47 kΩ

 

 

 

 

 

 

Sensor, floor (optional)

NTC 47 kΩ, 3 m, IP 68

 

 

 

 

 

Shell material

White parts: PC ASA

 

Grey parts: PC, 10% glass

 

 

 

 

 

 

 

 

IP and Protection class

IP: 21

 

Protection class: II

 

 

 

 

 

 

ErP class

(2%)

 

 

 

 

 

 

 

 

 

 

 

Approval

CE, RohS, WEEE

 

 

 

 

 

Colour

White RAL9010 / Dark Grey RAL7024

 

 

 

 

Dimensions, in-wall versions

86 x 86 x 11 mm (088U1021)

 

 

 

 

Dimensions, on-wall version

86 x 86 x 25 mm (088U1025)

 

 

 

 

 

2 | © Danfoss | FEC | 2019.03

VDSUD212

Loading...