Danfoss H1 Pump 3-Position FNR User guide

MAKING MODERN LIVING POSSIBLE
Electrical Installation
H1 Pump
3-Position (FNR) Electric Control
powersolutions.danfoss.com
Electrical Installation H1 Pump 3-Position (FNR) Electric Control
Revision history Table of revisions
Date Changed Rev
September 2015 Converted to Danfoss layout BA
January 2009 Corrected single and tandem pump tables AC
April 2007 Minor revision AB
March 2007 First edition AA
2 11025001 • Rev BASeptember 2015
Electrical Installation H1 Pump 3-Position (FNR) Electric Control

Contents

Literature references
H1 Pump 3-Position (FNR) Electric Control literature references....................................................................................4
Latest version of technical literature.........................................................................................................................................4
Product overview
Product image................................................................................................................................................................................... 5
Nomenclature....................................................................................................................................................................................5
Theory of operation.........................................................................................................................................................................6
Pump displacement versus electrical signal..................................................................................................................... 6
Hydrostatic drive line power...................................................................................................................................................6
Hydraulic schematics...................................................................................................................................................................... 6
Electrical specifications.................................................................................................................................................................. 6
Electrical installation
Pinout....................................................................................................................................................................................................7
DEUTSCH connector.................................................................................................................................................................. 7
Pin compatibility...............................................................................................................................................................................7
Input/output matrix........................................................................................................................................................................ 8
Mating connector.............................................................................................................................................................................8
DEUTSCH connector parts list ............................................................................................................................................... 8
11025001 • Rev BASeptember 2015 3
Electrical Installation H1 Pump 3-Position (FNR) Electric Control

Literature references

H1 Pump 3-Position (FNR) Electric Control literature references

Literature title Description Literature number
H1 Single and Tandem Axial Piston Pumps, Basic Information
PLUS+1® Compliant FNR Control Function Blocks User Manual

Latest version of technical literature

Danfoss product literature is online at: http://powersolutions.danfoss.com/literature/
Complete product electrical and mechanical specifications
Compliant function block set-up information
11062168
11022881
4 11025001 • Rev BASeptember 2015
A B D F E G H J K M N S T V W X Y
H1 P
A G N N N N N N N N
A B C D F E G H J K M N P R S T V W X Y
H1 T
A N N F N P N N N N N N N N
Electrical Installation

Product overview

Product image

Nomenclature

Single pump
H1 Pump 3-Position (FNR) Electric Control
H1 Pump 3-Position (FNR) Electric Control
Tandem pump
Code D Options
Option Description
A9 FNR control, 12 V, manual override B1 FNR control, 24 V, manual override
Only certain control options for the H1 pump utilize 3-Position (FNR) Electric Controll. Please refer to the pump’s nomenclature to determine if the pump is equipped with the proper option. The nomenclature can be found on the pump’s nametag.
11025001 • Rev BASeptember 2015 5
100 %
0
100 %
Voltage Vdc
Displacement
W
C1C2
F00A
M14
T PF00B
Electrical Installation H1 Pump 3-Position (FNR) Electric Control
Product overview

Theory of operation

The 3-position (FNR) Electric Control uses an electric input signal to switch the pump to a full stroke position.

Pump displacement versus electrical signal

Hydrostatic drive line power

Hydraulic schematics

Electrical specifications

Warning
Unintended vehicle or machine movement hazard. The loss of hydrostatic drive line power, in any mode of operation (forward, neutral, or reverse) may cause the system to lose hydrostatic braking capacity. You must provide a braking system, redundant to the hydrostatic transmission, sufficient to stop and hold the vehicle or machine in the event of hydrostatic drive power loss.
H1 pump 3-position (FNR) electrical specifications
Voltage Minimum supply voltage Maximum supply votage Rated power Coil resistance at 20º C [70º F]
12V 24V
9.5 Vdc 19 Vdc
14.6 Vdc 27 Vdc
17 W 17 W
8.4 Ω 34.5 Ω
6 11025001 • Rev BASeptember 2015
1 2
W

Electrical Installation

Electrical installation

Pinout

H1 Pump 3-Position (FNR) Electric Control

DEUTSCH connector

Pin location
Pinout
Pin Function
1 PWM signal 2 Ground
Pinout (alternative)
Pin Function
1 Ground 2 PWM signal

Pin compatibility

PLUS+1® module pin type
Pin Function
1,2 DOUT 1,2 DOUT/PVG Power 1, 2 PWMOUT/DOUT/PVG Power supply 1, 2 PWMOUT/DOUT/PVGOUT 1, 2 Power ground
Warning
Unintended vehicle or machine movement hazard. Verify the wiring harness to ensure the correct PLUS +1® pin is properly connected to each control pin.
11025001 • Rev BASeptember 2015 7
C1
C2
Electrical Installation H1 Pump 3-Position (FNR) Electric Control
Electrical installation

Input/output matrix

3-position FNR/C1 and C2 location
Single pump output flow direction versus control signal
Shaft rotation CW CCW
Front Rear Front Rear
Coil energized C1 C2 C1 C2 C1 C2 C1 C2
Port A in out out in — Port B out in in out — Servo port pressurized M5 M4 M5 M4 M5 M4 M5 M4

Mating connector

Tandem pump output flow direction versus control signal
Shaft rotation CW CCW
Front Rear Front Rear
Coil energized C1 C2 C1 C2 C1 C2 C1 C2
Port A in out out in — Port B out in in out — Port C in out out in Port D out in in out Servo port pressurized M5 M4 M5 M4 M5 M4 M5 M4

DEUTSCH connector parts list

Description Quantity Ordering number
Connector Wedge lock Socket contact (16 and 18 AWG) Mating connector kit
1 DEUTSCH DT06-2S 1 DEUTSCH W2S 2 DEUTSCH 0462-201-16141 1 Danfoss K29657
8 11025001 • Rev BASeptember 2015
Electrical Installation H1 Pump 3-Position (FNR) Electric Control
11025001 • Rev BASeptember 2015 9
Electrical Installation H1 Pump 3-Position (FNR) Electric Control
10 11025001 • Rev BASeptember 2015
Electrical Installation H1 Pump 3-Position (FNR) Electric Control
11025001 • Rev BASeptember 2015 11
Danfoss Power Solutions GmbH & Co. OHG
Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0
Danfoss Power Solutions ApS
Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222
Danfoss Power Solutions (US) Company
2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000
Danfoss Power Solutions Trading (Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 3418 5200
Products we offer:
Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmueller­inverter.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Bent Axis Motors
Closed Circuit Axial Piston
Pumps and Motors Displays
Electrohydraulic Power
Steering Electrohydraulics
Hydraulic Power Steering
Integrated Systems
Joysticks and Control
Handles Microcontrollers and
Software Open Circuit Axial Piston
Pumps Orbital Motors
PLUS+1® GUIDE
Proportional Valves
Sensors
Steering
Transit Mixer Drives
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles.
We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster.
Danfoss – Your Strongest Partner in Mobile Hydraulics.
Go to www.powersolutions.danfoss.com for further product information.
Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components.
Please contact the Danfoss Power Solution representative nearest you.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
11025001 • Rev BA • September 2015 www.danfoss.com
Local address:
©
Danfoss A/S, 2015
Loading...