Electrical InstallationH1 Pump 3-Position (FNR) Electric Control
Revision historyTable of revisions
DateChangedRev
September 2015Converted to Danfoss layoutBA
February 2009Removed Tandem pump, added Single pumpAD
January 2009Corrected single and tandem pump tablesAC
April 2007Minor revisionAB
March 2007First editionAA
211025001 • Rev BA • September 2015
Electrical InstallationH1 Pump 3-Position (FNR) Electric Control
Contents
Literature references
H1 Pump 3-Position (FNR) Electric Control literature references....................................................................................4
Latest version of technical literature.........................................................................................................................................4
Theory of operation.........................................................................................................................................................................6
Pump displacement versus electrical signal..................................................................................................................... 6
Hydrostatic drive line power...................................................................................................................................................6
DEUTSCH connector parts list ............................................................................................................................................... 8
11025001 • Rev BA • September 20153
Electrical InstallationH1 Pump 3-Position (FNR) Electric Control
Literature references
H1 Pump 3-Position (FNR) Electric Control literature references
Literature titleDescriptionLiterature number
H1 Single and Tandem Axial Piston Pumps, Basic
Information
PLUS+1® Compliant FNR Control Function Blocks User
Manual
Latest version of technical literature
Danfoss product literature is online at: http://powersolutions.danfoss.com/literature/
Complete product electrical
and mechanical
specifications
Only certain control options for the H1 pump utilize 3-Position (FNR) Electric Controll. Please refer to the
pump’s nomenclature to determine if the pump is equipped with the proper option. The nomenclature
can be found on the pump’s nametag.
11025001 • Rev BA • September 20155
100 %
0
100 %
Voltage Vdc
Displacement
W
C1C2
F00A
M14
TPF00B
Electrical InstallationH1 Pump 3-Position (FNR) Electric Control
Product overview
Theory of operation
The 3-position (FNR) Electric Control uses an electric input signal to switch the pump to a full stroke
position.
Pump displacement versus electrical signal
Hydrostatic drive line power
Hydraulic schematics
Electrical specifications
Warning
Unintended vehicle or machine movement hazard. The loss of hydrostatic drive line power, in any mode
of operation (forward, neutral, or reverse) may cause the system to lose hydrostatic braking capacity. You
must provide a braking system, redundant to the hydrostatic transmission, sufficient to stop and hold the
vehicle or machine in the event of hydrostatic drive power loss.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Products we offer:
Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmuellerinverter.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Bent Axis Motors
•
Closed Circuit Axial Piston
•
Pumps and Motors
Displays
•
Electrohydraulic Power
•
Steering
Electrohydraulics
•
Hydraulic Power Steering
•
Integrated Systems
•
Joysticks and Control
•
Handles
Microcontrollers and
•
Software
Open Circuit Axial Piston
•
Pumps
Orbital Motors
•
PLUS+1® GUIDE
•
Proportional Valves
•
Sensors
•
Steering
•
Transit Mixer Drives
•
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market. Building on
our extensive applications expertise, we work closely with our customers to ensure
exceptional performance for a broad range of off-highway vehicles.
We help OEMs around the world speed up system development, reduce costs and bring
vehicles to market faster.
Danfoss – Your Strongest Partner in Mobile Hydraulics.
Go to www.powersolutions.danfoss.com for further product information.
Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support
for our customers, ensuring the best possible solutions for outstanding performance. And
with an extensive network of Global Service Partners, we also provide comprehensive global
service for all of our components.
Please contact the Danfoss Power Solution representative nearest you.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.