Data Sheet
H1P 115/130
Axial Piston Single Pumps
For more than 40 years, Danfoss has been developing
state-of-the-art components and systems for mobile
machinery used in off-highway operations around the
world.
We have become a preferred supplier by offering the
best of what really matters: The hardware inside your
vehicle application.
The H1 range is built around an advanced control and
available in a wide range of displacements. It is
designed for quality and reliability and offers
expanded functionality, greater total efficiency, and
easy installation.
All H1 control and sensor options are PLUS+1
Compliant. PLUS+1® allows you to rapidly develop
and customize electronic machine control. It opens
up the future by combining machine controls and
diagnostics in an integrated operating network.
®
Features
Designed for quality and reliability
•
One design concept
•
Single piece swash plate
Wide range of controls
•
Electro-hydraulic controls:
Electrical Displacement Control
‒
(EDC)
Forward-Neutral-Reverse (FNR)
‒
Non-Feedback Proportional Electric
‒
(NFPE)
•
Automotive Control (AC)
•
Fan Drive Control (FDC)
•
Manual Displacement Control (MDC)
•
Hydraulic Displacement Control (HDC)
•
Common control across entire family
Comprehensive technical literature is online at www.danfoss.com
Greater total efficiency
•
Minimized control losses
•
Improved charge circuit
•
Lower control pressure for less power
consumption
Installation and packaging benefits
•
Length optimized pump
•
Minimum one clean side
•
Higher corner HP / package size ratio
•
Standardized connector interface
Expanded functionality
•
PLUS+1® Compliant control and sensor
options
•
Integral filtration available with
integrated filter bypass sensors and
switch
For more information see the H1P 115/130
Axial Piston Single Pumps Technical
Information, BC00000198.
©
Danfoss | December 2021 AI152886482843en-000801 | 1
Technical Specifications
S
F00B
C1
C2
F00A
M4
M5
M14
M3 L2 MA
A
CW
MB
P003 417
B
M6 1 2
R1
R2
L4
152.4
0
-0.05
Z
X
Y
CCW
CW
223.7 ±2.0
138.3 ±2.0
306.916 ±1.0
15.9 ±1.0
298.1 ±1.0
Z
Y
12.45±0.25
316.9 max
204.32 ± 2.0
110.0 ± 2.0
4x 80.8 ±0.25
4x 80.8 ±0.25
4x 20.6
+ 0.25
– 0.13
L4
M14
E
F
M5
L2
M3
M6
MB
A
B
S
M4
148.08 ±1.
0
121.89 ±1.0
X
2
1
1
MA
E
F
MB
Parameters Size 115 Size 130
Displacement cm3 [in3] 115.2 [7.03] 130.0 [7.93]
Input speed
min-1 (rpm)
System pressure
bar [psi]
Case pressure
bar [psi]
Weight (without PTO and filter), kg [lb] 83 [187]
*
Pressures above max. working pressure requires Danfoss approval.
Minimum 500
Rated 3200
Maximum 3400
Max. working
*
450 [6528]
Maximum 480 [6960]
Min. low loop 10 [145]
Rated 3.0 [44.0]
Maximum 5.0 [73.0]
Schematic
A/B system ports: Ø31.5 mm; M12 x 1.75; 20 min. full thread depth
MA/MB (system), M3, M6 (charge) gauge ports per ISO 11926-1: 9∕16–18
M4, M5 (servo), M14 (case) gauge ports per ISO 11926-1: 7∕16–20
L2, L4 – Case drain ports per ISO 11926-1: 15∕16–12
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
E/F – Charge filtration ports per ISO 11926-1: 11∕16–12
S – Charge inlet port per ISO 11926-1: 15∕8–12 (SAE O-ring boss)
1 – Case pressure port per ISO 11926-1: 11∕16–2
2 – Connector DEUTSCH DT04-2P, to be paint free
2 | © Danfoss | December 2021 AI152886482843en-000801