Danfoss H16 Technical Information

Cartridge Valves Coils Technical Information
H16
SPECIFICATIONS Duty cycle: 100% at 115% of rated voltage
at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating:
IP69K: AS, DE, FL and M3
Input voltage range: 85% to 115% of rated voltage
Optional bi-directional transient voltage suppression diodes: Non polarity dependent, 51 volt nominal breakdown voltage
Weight: 0.34 kg [0.75 lb]
ELECTRICAL SPECIFICATIONS
TERMINALS
29 watt coils
Voltage (V) 12 VDC 24 VDC
Resistance (Ohms) @ 20 °C [68 °F] 4.8 19.8
Current draw (A) @ 20 °C [68 °F] 2.48 1.21
Amp SuperSeal 1.5/MetriPak 150 Type 1 Code AS
Amp SuperSeal 1.5/MetriPak 150 Type 1 w/Diode Bi-Directional Code ASDB
Part numbers
Voltage (V) Resistance (Ohm) Part Number
12 4.8 H16-12D-29W-AS
24 19.8 H16-24D-29W-AS
Part numbers
Voltage (V) Resistance (Ohm) Part Number
12 4.8 H16-12D-29W-AS-DB
24 19.8 H16-24D-29W-AS-DB
BC332376631124en-000101 • February 2020
CL - 17
Cartridge Valves Coils Technical Information
H16
TERMINALS (continued)
Deutsch Code DE
Deutsch w/Diode, Bi-Directional Code DEDB
Part numbers
Voltage (V) Resistance (Ohm) Part Number
12 4.8 H16-12D-29W-DE
24 19.8 H16-24D-29W-DE
Part numbers
Voltage (V) Resistance (Ohm) Part Number
12 4.8 H16-12D-29W-DE-DB
24 19.8 H16-24D-29W-DE-DB
Lead wires Code FL
Lead wires w/Diode, Bi-Directional Code FLDB
Part numbers
Voltage (V) Resistance (Ohm) Part Number
12 4.8 H16-12D-29W-FL
24 19.8 H16-24D-29W-FL
Part numbers
Voltage (V) Resistance (Ohm) Part Number
12 4.8 H16-12D-29W-FL-DB
24 19.8 H16-24D-29W-FL-DB
BC332376631124en-000101 • February 2020
CL - 18