Danfoss H1 078, H1 069, H1 089, H1 115, H1 100 Service Manual

...
Service Manual
Axial Piston Pumps
H1 - 069/078, 089/100, 115/130, 147/165, 210/250
www.danfoss.com
Revision history Table of revisions
May 2018 add angle sensor 0308
January 20187 add seal carrier to shaft repair topic 0307
February 2017 minor edit - shaft repair illustration 0306
January 2017 minor edit 0305
September 2016 minor edits 0304
July 2016 minor edits 0303
January 2016 minor edits 0302
July 2015 add 210/250 0300
September 2014 Danfoss layout - add MDC BA
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
2 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Introduction
Overview..............................................................................................................................................................................................5
Warranty.............................................................................................................................................................................................. 5
General instructions........................................................................................................................................................................ 5
Remove the unit.......................................................................................................................................................................... 5
Keep it clean..................................................................................................................................................................................5
Replace all O-rings and gaskets............................................................................................................................................. 5
Secure the unit.............................................................................................................................................................................5
Safety Precautions............................................................................................................................................................................5
Unintended machine movement..........................................................................................................................................6
Flammable cleaning solvents.................................................................................................................................................6
Fluid under pressure..................................................................................................................................................................6
Personal safety............................................................................................................................................................................. 6
Symbols used in Danfoss literature............................................................................................................................................7
Design...................................................................................................................................................................................................7
The System Circuit............................................................................................................................................................................8
Operation
Pressure Limiter Valves................................................................................................................................................................ 11
High Pressure Relief Valve (HPRV) and Charge Check......................................................................................................11
Bypass Function..............................................................................................................................................................................12
Charge Pressure Relief Valve......................................................................................................................................................12
Electrical Displacement Control (EDC)................................................................................................................................... 13
Manual OverRide (MOR).............................................................................................................................................................. 14
Manual Displacement Control (MDC) ....................................................................................................................................15
MDC Torque................................................................................................................................................................................16
Operating parameters
Input speed...................................................................................................................................................................................... 18
System pressure............................................................................................................................................................................. 18
Servo pressure.................................................................................................................................................................................18
Charge pressure..............................................................................................................................................................................19
Charge pump inlet pressure...................................................................................................................................................... 19
Case pressure...................................................................................................................................................................................19
External shaft seal pressure........................................................................................................................................................19
Temperature and viscosity......................................................................................................................................................... 20
Technical Specifications
Overview........................................................................................................................................................................................... 21
General Specifications..................................................................................................................................................................21
Physical Properties.........................................................................................................................................................................21
Operating Parameters .................................................................................................................................................................22
Fluid Specifications....................................................................................................................................................................... 22
Fluid and Filter Maintenance
Fluid and Filter Recommendations......................................................................................................................................... 23
Pressure Measurements
Port Locations and Gauge Installation...................................................................................................................................24
Initial Startup Procedures
General ..............................................................................................................................................................................................26
Start-Up Procedure........................................................................................................................................................................26
Troubleshooting
Overview........................................................................................................................................................................................... 27
Safety Precautions......................................................................................................................................................................... 27
Electrical Troubleshooting..........................................................................................................................................................27
System Operating Hot..................................................................................................................................................................27
Integral Filter Bypass.....................................................................................................................................................................28
Neutral Difficult or Impossible to Find................................................................................................................................... 28
System Will Not Operate in Either Direction........................................................................................................................28
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Contents
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 3
System Noise or Vibration...........................................................................................................................................................29
Sluggish System Response.........................................................................................................................................................29
Transmission Operates Normally in One Direction Only.................................................................................................30
Adjustments
Standard Procedures.................................................................................................................................................................... 31
Charge Pressure Relief Valve Adjustments...........................................................................................................................31
Pressure Limiter Adjustment..................................................................................................................................................... 32
Engaging the Bypass Function..................................................................................................................................................34
Displacement Limiter Adjustment...........................................................................................................................................35
Control Neutral Adjustment.......................................................................................................................................................36
Mechanical Neutral Adjustment...............................................................................................................................................37
Minor Repair
Standard Procedures, Removing the Pump.........................................................................................................................40
EDC Control......................................................................................................................................................................................40
Control Solenoids...........................................................................................................................................................................42
MDC Control.................................................................................................................................................................................... 42
Angle sensor on EDC.....................................................................................................................................................................45
Removal........................................................................................................................................................................................45
Installation...................................................................................................................................................................................46
EDC with angle sensor..................................................................................................................................................................46
Removal........................................................................................................................................................................................46
Installation...................................................................................................................................................................................47
Automotive Control...................................................................................................................................................................... 48
Bearing and Shaft Replacement...............................................................................................................................................52
External Filter Replacement....................................................................................................................................................... 53
Filter Bypass Valve and Filter Bypass Switch........................................................................................................................54
Charge Pump...................................................................................................................................................................................55
High Pressure Relief Valves (HPRV)..........................................................................................................................................58
Charge Pressure Relief Valve......................................................................................................................................................59
Pressure Limiter Valve Replacement.......................................................................................................................................60
Torque Chart
Fastener Size and Torques..........................................................................................................................................................62
Plug Size and Torques..................................................................................................................................................................62
Fasteners and Plugs...................................................................................................................................................................... 63
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Contents
4 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Overview
This manual includes information on the installation, maintenance, and minor repair of H1 pumps. It includes a description of the unit and its individual components, troubleshooting information, and minor repair procedures.
Performing minor repairs requires the unit to be removed from the vehicle/machine. Thoroughly clean the unit before beginning maintenance or repair activities. Since dirt and contamination are the greatest enemies of any type of hydraulic equipment, follow cleanliness requirements strictly. This is especially important when changing the system filter and when removing hoses or plumbing.
A worldwide network of Danfoss Authorized Service Centers is available for major repairs. Danfoss trains and certifies Authorized Service Centers on a regular basis. You can locate your nearest Authorized Service Center using the distributor locator at www.Danfoss.com.
Warranty
Performing adjustments and minor repairs according to the procedures in this manual will not affect your warranty. Major repairs requiring the removal of a unit’s center section, servo sleeves, or front flange voids the warranty unless a Danfoss Authorized Service Center performs them.
General instructions
Remove the unit
If necessary, remove the unit from the vehicle/machine. Chock the wheels on the vehicle or lock the mechanism to inhibit movement. Be aware that hydraulic fluid may be under high pressure and/or hot. Inspect the outside of the pump and fittings for damage. Cap hoses after removal to prevent contamination.
Keep it clean
Cleanliness is a primary means of assuring satisfactory pump life on either new or repaired units. Clean the outside of the pump thoroughly before disassembly. Take care to avoid contamination of the system ports. Cleaning parts by using a clean solvent wash and air drying is usually adequate.
As with any precision equipment, you must keep all parts free of foreign material and chemicals. Protect all exposed sealing surfaces and open cavities from damage and foreign material. If left unattended, cover the pump with a protective layer of plastic.
Replace all O-rings and gaskets
Danfoss recommends that you replace all O-rings, seals and gaskets. Lightly lubricate all O-rings with clean petroleum jelly prior to assembly.
Secure the unit
If removed from machine, place the unit in a stable position with the shaft pointing downward. It will be necessary to secure the pump while removing and torquing fasteners and components.
Safety Precautions
Always consider safety precautions before beginning a service procedure. Protect yourself and others from injury. Take the following general precautions whenever servicing a hydraulic system.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Introduction
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 5
Unintended machine movement
W
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. To protect against unintended movement, secure the machine or disable/disconnect the mechanism while servicing.
Flammable cleaning solvents
W
Warning
Some cleaning solvents are flammable. To avoid possible fire, do not use cleaning solvents in an area where a source of ignition may be present.
Fluid under pressure
W
Warning
Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin causing serious injury and/or infection. This fluid may also be hot enough to cause burns. Use caution when dealing with hydraulic fluid under pressure. Relieve pressure in the system before removing hoses, fittings, gauges, or components. Never use your hand or any other body part to check for leaks in a pressurized line. Seek medical attention immediately if you are cut by hydraulic fluid.
Personal safety
W
Warning
Protect yourself from injury. Use proper safety equipment, including safety glasses, at all times.
Hazardous Material
W
Warning
Hydraulic fluid contains hazardous material. Avoid prolonged contact with hydraulic fluid. Always dispose of used hydraulic fluid according to state, and federal environmental regulations.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Introduction
6 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Symbols used in Danfoss literature
WARNING may result in injury Tip, helpful suggestion
CAUTION may result in damage to product or property
Lubricate with hydraulic fluid
Reusable part Apply grease / petroleum jelly
Non-reusable part, use a new part Apply locking compound
Non-removable item Inspect for wear or damage
Option - either part may exist Clean area or part
Superseded - parts are not interchangeable Be careful not to scratch or damage
Measurement required Note correct orientation
Flatness specification Mark orientation for reinstallation
Parallelism specification Torque specification
External hex head Press in - press fit
Internal hex head Pull out with tool – press fit
Torx head Cover splines with installation sleeve
O-ring boss port Pressure measurement/gauge location or
specification
The symbols above appear in the illustrations and text of this manual. They are intended to communicate helpful information at the point where it is most useful to the reader. In most instances, the appearance of the symbol itself denotes its meaning. The legend above defines each symbol and explains its purpose.
Design
Danfoss H1 closed circuit piston pumps convert input torque into hydraulic power. The input shaft transmits rotational force to the cylinder block. Bearings at the front and rear of the pump support the shaft. Splines connect the shaft to the cylinder block. A lip-seal at the front end of the pump prevents leakage where the shaft exits the pump housing. The spinning cylinder block contains nine reciprocating pistons. Each piston has a brass slipper connected at one end by a ball joint. The block spring, ball guide, and slipper retainer hold the slippers to the swashplate. The reciprocating movement of the pistons occurs as the slippers slide against the inclined swashplate during rotation. Via the valve plate, one half of the cylinder block is connected to low pressure and the other half to high pressure. As each piston cycles in and out of its bore, fluid is replenished by charge flow and displaced to the outlet thereby imparting hydraulic power into the system. A small amount of fluid is allowed to flow from the cylinder block/valve plate and slipper/swashplate interfaces for lubrication and cooling. Case drain ports return this fluid to the reservoir.
The angle of the swashplate controls the volume and direction of fluid displaced into the system. The servo piston controls the angle of the swashplate. The pump control, by varying the pressure at the servo piston, controls the piston’s position. An electric signal to the control coils transmits the command from the operator to the pump. Mechanical feedback of the swashplate position to the control through the feedback pins allows for very precise displacement control and increases overall system stability. Non­feedback control options do not use the mechanical feedback link.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Introduction
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 7
Cross section view
Swashplate
Cylinder block
Auxiliary mounting pad “B”
Charge pump
Servo piston
Piston
Shaf t seal
Shaf
t
Slippe
r
Electric displacement control
P106 045E
Valve plate
Swashplate feedback pin
The System Circuit
The Basic Closed Circuit
Hydraulic lines connect the main ports of the pump to the main ports of the motor. Fluid flows in either direction from the pump to the motor and back. Either of the hydraulic lines can be under high pressure. In pumping mode the position of the pump swashplate determines which line is high pressure as well as the direction of fluid flow.
Case Drain and Heat Exchanger
The pump and motor require case drain lines to remove hot fluid from the system. The pump and motor drain from the topmost port to ensure the cases remain full of fluid. The motor case drain can connect to the lower drain port on the pump housing or it can tee into the case drain line upstream of the heat exchanger. A heat exchanger with bypass valve cools the case drain fluid before it returns to the reservoir.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Introduction
8 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
System Circuit Diagram
P003 423E
Reservoir
Heat Exchanger
Bypass Valve
Heat Exchanger
Electric
Displacement
Control
Servo Cylinder
Input
Shaft
Pump
Swashplate
Pressure Limiter Valve
Pressure Limiter
Valve
Charge Check/
High Pressure
Relief Valve
Charge Check/
High Pressure
Relief Valve
To
Motor
Case
Charge
Pressure
Relief
Valve
Loop
Flushing
Valve
Charge Pressure
Filter
Charge
Pump
Output
Shaft
Valve
Segment
Bent Axis Variable
Displacement Motor
Variable
Displacement
Pump
Case
Drain
Working Loop A (Low Pressure)
and Charge Pressure
Servo
Pressure
Working Loop B
(High Pressure)
Suction
H1 Pump and H1 Motor with Electric proportional control
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Introduction
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 9
System Schematic
P003 424
min.max.
L2 NMA
A
B
M5
MB
M4
L1
B
R1
R2
M4
M5
M14 M6 1 2
M3 L1 L2 MA
A
C2 C1
S
F00B F00A
L3 L4
CW
MB
max. 3 bar [43.5 psi]
n
The schematic above shows the function of a hydrostatic transmission using an H1 axial variable displacement pump with electric proportional displacement control (EDC) and an H1 bent axis variable displacement motor with electric proportional control (L*) and integrated loop flushing device.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Introduction
10 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Pressure Limiter Valves
Pressure limiter valves provide system pressure protection by compensating the pump swashplate position when the set pressure of the valve is reached. A pressure limiter is a non-dissipative (non heat generating) pressure regulating system.
Each side of the transmission loop (and each section of the tandem pump) has a dedicated pressure limiter valve that is set independently. Each system port may have a different pressure limiter setting.
The pressure limiter setting is the maximum differential pressure between the high and low loops. When the pressure limiter setting is reached, the valve ports oil to the lowpressure side of the servo piston. The change in pressure across the servo rapidly reduces pump displacement. Fluid flow from the valve continues until the resulting drop in pump displacement causes system pressure to fall below the pressure limiter setting.
An active pressure limiter destrokes the pump to near neutral when the load is in a stalled condition. The pump swashplate moves in either direction necessary to regulate the system pressure, including increasing stroke when over-running or over-center.
The pressure limiter is optional on H1 pumps.
069/078/089/100 Single Pumps
115/130/147/165/210/250 Single Pumps
High Pressure Relief Valve (HPRV) and Charge Check
All H1 pumps have a combination high pressure relief and charge check valve. The high-pressure relief function is a dissipative (heat generating) pressure control valve for the purpose of limiting excessive system pressures. The charge check function replenishes the low-pressure side of the working loop with charge oil. Each side of the transmission loop has a dedicated non-adjustable, factory-set HPRV valve. When system pressure exceeds the factory setting of the valve, it passes oil from the high pressure system loop into the charge gallery and the low pressure system loop via the charge check.
The pump may have different pressure settings at each system port. When an HPRV valve is used in conjunction with a pressure limiter, the HPRV valve is always factory set above the setting of the pressure limiter. The system pressure shown in the order code for pumps with only HPRV is the HPRV setting. The system pressure shown in the order code for pumps with both pressure limiter and HPRV is the pressure limiter setting.
HPRVs are set at low flow condition. Any application or operating condition which leads to elevated HPRV flow will cause a pressure rise with flow above the valve setting. Consult factory for application.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operation
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 11
High Pressure Relief and Charge Check Valve with Bypass Valve in charging mode
P003 269
High Pressure Relief and Charge Check Valve with Bypass Valve in relief mode
P003 268
Pressures marked on HPRV valve
Mark Pressure bar [psi]
20 200 [2900] 25 250 [3626] 30 300 [4351] 35 350 [5076] 37 370 [5366] 40 400 [5801] 42 420 [6092] 45 450 [6527] 48 480 [6962] 51 510 [7397]
Bypass Function
The HPRV valve also provides a loop bypass function when each of the two HPRV hex plugs are mechanically backed out 3 full turns. Engaging the bypass function hydraulically connects both A & B sides of the working loop to the common charge gallery. The bypass function allows you to move a machine or load without rotating the pump shaft or prime mover.
C
Caution
The HPRV valves are not tow valves. Damage to the pump and motor can occur when operating without charge flow. Limit vehicle/machine movement to no more than 20% of maximum speed and no longer that three minutes. Reseat the HPRV valves after vehicle/machine movement.
Charge Pressure Relief Valve
The charge pressure relief valve maintains charge pressure at a designated level above case pressure. The charge pressure relief valve is a direct acting poppet valve that opens and discharges fluid to the pump case when pressure exceeds a designated level. This level is nominally set with the pump running at 1800
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operation
12 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
min-1 (rpm). For external charge flow, the CPRV is set with with a flow of 30 l/min [8 US gal/min]. In forward or reverse, charge pressure will be slightly lower than in neutral position. The model code of the pump specifies the charge relief setting.
Typically charge pressure increases from 1.2-1.5 bar per 10 l/min [17.4-21.8 psi per 2.64 US gal/min] case flow.
Charge Pressure Relief Valve
Electrical Displacement Control (EDC)
EDC Principle
The Electrical Displacement Control (EDC) consists of proportional solenoids on each side of a three­position, four-way porting spool. The proportional solenoid applies a force to the spool, which ports hydraulic fluid to either side of the servo piston. Differential pressure across the servo piston rotates the swashplate, changing the pump‘s displacement from full displacement in one direction to full displacement in the opposite direction.
EDC Operation
H1 EDC’s are current driven controls requiring a Pulse Width Modulated (PWM) signal. Pulse width modulation allows more precise control of current to the solenoids. The PWM signal causes the solenoid pin to push against the porting spool, which pressurizes one end of the servo piston, while draining the other. Pressure differential across the servo piston moves the swashplate. A swashplate feedback link, opposing control links, and a linear spring provide swashplate position force feedback to the solenoid. The control system reaches equilibrium when the position of the swashplate spring feedback force exactly balances the input command solenoid force from the operator. As hydraulic pressures in the operating loop change with load, the control assembly and servo/swashplate system work constantly to maintain the commanded position of the swashplate.
The EDC incorporates a positive neutral dead-band as a result of the control spool porting, spring preload from the servo piston assembly, and the linear control spring. Once the neutral threshold current is reached, the swashplate position becomes directly proportional to the control current. To minimize the effect of the control neutral deadband, we recommended the transmission controller or operator input device incorporate a jump up current.
The neutral position of the control spool does provide a positive preload pressure to each end of the servo piston assembly.
When the control input signal is either lost or removed, or if there is a loss of charge pressure, the spring­loaded servo piston automatically returns the pump to neutral position.
The EDC is a displacement (flow) control. Pump swashplate position is proportional to the input command and therefore vehicle or load speed (excluding influence of efficiency), is dependent only on the prime mover speed or motor displacement.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operation
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 13
EDC Schematic Diagram
Feedback from Swash plate
PTF00B
M14
1C2C
F00A
P003 478E
Manual OverRide (MOR)
All controls are available with a Manual OverRide (MOR) for temporary actuation of the control to aid in diagnosis. FNR controls always include MOR functionality.
W
Warning
Depressing the plunger causes the pump to go into stroke which will move the machine or mechanism. Ensure the vehicle or machine is in a safe condition (wheels off the ground or mechanism disconnected) before attempting to use the MOR feature.
An O-ring seals the MOR plunger. Initial actuation of the function requires additional force to overcome the O-ring resistance. A threshold force of 45 N is typically required at first actuation. Additional actuations typically require a threshold force of 12 N to move the MOR plunger. Force required to keep the pump at full stroke is typically 51 N. Do not expect proportional control of the pump using the MOR.
Refer to control flow table for the relationship of solenoid to direction of flow.
Control Solenoid
P003 204
EDC Schematic Diagram Showing Manual OverRide
Feedback from Swash plate
PTF00B
M14
C1
C2
F00A
P003 205E
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operation
14 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Manual Displacement Control (MDC)
A Manual proportional Displacement Control (MDC) consists of a handle on top of a rotary input shaft. The shaft provides an eccentric connection to a feedback link. This link is connected on its one end with a porting spool. On its other end the link is connected the pumps swashplate.
This design provides a travel feedback without spring. When turning the shaft the spool moves thus providing hydraulic pressure to either side of a double acting servo piston of the pump.
Differential pressure across the servo piston rotates the swash plate, changing the pump’s displacement. Simultaneously the swashplate movement is fed back to the control spool providing proportionality between shaft rotation on the control and swashplate rotation.
The MDC changes the pump displacement between no flow and full flow into opposite directions. Under some circumstances, such as contamination, the control spool could stick and cause the pump to stay at some displacement.
A serviceable 125 μm screen is located in the supply line immediately before the control porting spool. The MDC is sealed by means of a static O-ring between the actuation system and the control block. Its
shaft is sealed by means of a special O-ring which is applied for low friction. The special O-ring is protected from dust, water and aggressive liquids or gases by means of a special lip seal.
Manual Displacement Control
P301 749
Pump displacement vs. control lever rotation
"0"
Lever rotation
"A"
Displacement
100 %
a
-a
100 %
"B"
-b
-d b
c
d
-c
P301 752
Legend:
Deadband on B side – a = 3° ±1° Maximum pump stroke – b = 30° +2/-1° Required customer end stop – c = 36° ±3° Internal end stop – d = 40°
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operation
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 15
MDC Torque
Description Value
Torque required to move handle to maximum displacement 1.4 N•m [12.39 lbf•in ] Torque required to hold handle at given displacement 0.6 N•m [5.31 lbf•in] Maximum allowable input torque 20 N•m [177 lbf•in]
C
Caution
Volumetric efficiencies of the system will have impacts on the start and end input commands.
MDC General Information
In difference to other controls the MDC provides a mechanical deadband. This is required to overcome the tolerances in the mechanical actuation.
The MDC contains an internal end stop to prevent over travel. The restoring moment is appropriate for turning the MDC input shaft back to neutral only. Any linkages or cables may prevent the MDC from returning to neutral.
The MDC is designed for a maximum case pressure of 5 bar and a rated case pressure of 3 bar. If the case pressure exceeds 5 bar there is a risk of an insufficient restoring moment. In addition a high case pressure can cause the NSS to indicate that the control is not in neutral. High case pressure may cause excessive wear.
Customers can apply their own handle design but they must care about a robust clamping connection between their handle and the control shaft and avoid overload of the shaft.
Customers can connect two MDC’s on a tandem unit in such a way that the actuation force will be transferred from the pilot control to the second control but the kinematic of the linkages must ensure that either control shaft is protected from torque overload. To avoid an overload of the MDC, customers must install any support to limit the setting range of the Bowden cable.
C
Caution
Using the internal spring force on the input shaft is not an appropriate way to return the customer connection linkage to neutral.
General information - CCO
For the MDC with CCO option the brake port (X7) provides charge pressure when the coil is energized to activate static function such as a brake release. The X7 port must not be used for any continuous oil consumption.
Neutral Start Switch (NSS)
The Neutral Start Switch (NSS) contains an electrical switch that provides a signal of whether the control is in neutral. The signal in neutral is Normally Closed (NC).
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operation
16 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Neutral Start Switch schematic
P005 702
M14
M5
M4
M3
Neutral Start Switch data
Max. continuous current with switching
8.4 A
Max. continuous current without switching
20 A
Max. voltage
36 V
DC
Electrical protection class
IP67 / IP69K with mating connector
Case Gauge Port M14
The drain port should be used when the control is mounted on the unit’s bottom side to flush residual contamination out of the control.
MDC schematic diagram
P005 701
M14
M5
M4
M3
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operation
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 17
Input speed
Minimum speed is the lowest input speed recommended during engine idle condition. Operating below
minimum speed limits the pump’s ability to maintain adequate flow for lubrication and power transmission.
Rated speed is the highest input speed recommended at full power condition. Operating at or below this speed should yield satisfactory product life.
Maximum speed is the highest operating speed permitted. Exceeding maximum speed reduces product life and can cause loss of hydrostatic power and braking capacity. Never exceed the maximum speed limit under any operating conditions.
Operating conditions between Rated and Maximum speed should be restricted to less than full power and to limited periods of time. For most drive systems, maximum unit speed occurs during downhill braking or negative power conditions.
For more information consult Pressure and speed limits, BLN-9884, when determining speed limits for a particular application.
During hydraulic braking and downhill conditions, the prime mover must be capable of providing sufficient braking torque in order to avoid pump over speed. This is especially important to consider for turbocharged and Tier 4 engines.
W
Warning
Unintended vehicle or machine movement hazard
Exceeding maximum speed may cause a loss of hydrostatic drive line power and braking capacity. You must provide a braking system, redundant to the hydrostatic transmission, sufficient to stop and hold the vehicle or machine in the event of hydrostatic drive power loss. The braking system must also be sufficient to hold the machine in place when full power is applied.
System pressure
System pressure is the differential pressure between high pressure system ports. It is the dominant
operating variable affecting hydraulic unit life. High system pressure, which results from high load, reduces expected life. Hydraulic unit life depends on the speed and normal operating, or weighted average, pressure that can only be determined from a duty cycle analysis.
Application pressure is the high pressure relief or pressure limiter setting normally defined within the order code of the pump. This is the applied system pressure at which the driveline generates the maximum calculated pull or torque in the application.
Maximum working pressure is the highest recommended application pressure. Maximum working pressure is not intended to be a continuous pressure. Propel systems with application pressures at, or below, this pressure should yield satisfactory unit life given proper component sizing.
Maximum pressure is the highest allowable application pressure under any circumstance. Application pressures above Maximum Working Pressure will only be considered with duty cycle analysis and factory approval.
Pressure spikes are normal and must be considered when reviewing Maximum Working pressure.
Minimum low loop pressure must be maintained under all operating conditions to avoid cavitation.
All pressure limits are differential pressures referenced to low loop (charge) pressure. Subtract low loop pressure from gauge readings to compute the differential.
Servo pressure
Servo pressure is the pressure in the Servosystem needed to position and hold the pump on stroke. It depends on system pressure and speed. At minimum servo pressure the pump will run at reduced stroke depending on speed and pressure.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operating parameters
18 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Minimum servo pressure at corner power holds the pump on full stroke at max speed and max pressure.
Maximum servo pressure is the highest pressure typically given by the charge pressure setting.
Charge pressure
An internal charge relief valve regulates charge pressure. Charge pressure supplies the control with pressure to operate the swashplate and to maintain a minimum pressure in the low side of the transmission loop.
The charge pressure setting listed in the order code is the set pressure of the charge relief valve with the pump in neutral, operating at 1800 min-1 [rpm], and with a fluid viscosity of 32 mm²/s [150 SUS].
Pumps configured with no charge pump (external charge supply) are set with a charge flow of 30 l/min [7.93 US gal/min] and a fluid viscosity of 32 mm²/s [150 SUS].
The charge pressure setting is referenced to case pressure. Charge pressure is the differential pressure above case pressure.
Minimum charge pressure is the lowest pressure allowed to maintain a safe working condition in the low side of the loop. Minimum control pressure requirements are a function of speed, pressure, and swashplate angle, and may be higher than the minimum charge pressure shown in the Operating parameters tables.
Maximum charge pressure is the highest charge pressure allowed by the charge relief adjustment, and which provides normal component life. Elevated charge pressure can be used as a secondary means to reduce the swashplate response time.
Charge pump inlet pressure
At normal operating temperature charge inlet pressure must not fall below rated charge inlet pressure (vacuum). Minimum charge pump inlet pressure is only allowed at cold start conditions. In some
applications it is recommended to warm up the fluid (e.g. in the tank) before starting the engine and then run the engine at limited speed. Maximum charge pump inlet pressure may be applied continuously.
Case pressure
Under normal operating conditions, the rated case pressure must not be exceeded. During cold start case pressure must be kept below maximum intermittent case pressure. Size drain plumbing accordingly.
Auxiliary Pad Mounted Pumps. The auxiliary pad cavity of H1 pumps configured without integral charge pumps is referenced to case pressure. Units with integral charge pumps have auxiliary mounting pad cavities referenced to charge inlet (vacuum).
C
Caution
Possible component damage or leakage.
Operation with case pressure in excess of stated limits may damage seals, gaskets, and/or housings, causing external leakage. Performance may also be affected since charge and system pressure are additive to case pressure.
External shaft seal pressure
In certain applications, the input shaft seal may be exposed to external pressures. The shaft seal is designed to withstand an external pressure up to 0.4 bar [5.8 psi] above the case pressure. The case pressure limits must also be followed to ensure the shaft seal is not damaged.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operating parameters
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 19
Temperature and viscosity
Temperature
The high temperature limits apply at the hottest point in the transmission, which is normally the motor case drain. The system should generally be run at or below the quoted rated temperature.
The maximum intermittent temperature is based on material properties and should never be exceeded.
Cold oil will generally not affect the durability of the transmission components, but it may affect the ability of oil to flow and transmit power; therefore temperatures should remain 16 °C [30 °F] above the pour point of the hydraulic fluid.
The minimum temperature relates to the physical properties of component materials. Size heat exchangers to keep the fluid within these limits. Danfoss recommends testing to verify that
these temperature limits are not exceeded.
Viscosity
For maximum efficiency and bearing life, ensure the fluid viscosity remains in the recommended range. The minimum viscosity should be encountered only during brief occasions of maximum ambient
temperature and severe duty cycle operation. The maximum viscosity should be encountered only at cold start.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operating parameters
20 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Overview
Specifications and operating parameters for pumps are given here for reference.
General Specifications
Design Axial piston pump of cradle swashplate design with variable displacement Direction of rotation Clockwise, counterclockwise Pipe connections Main pressure ports: SAE straight thread O-ring boss
Remaining ports: SAE straight thread O-ring boss
Recommended installation position Pump installation recommended with control position on the top or side. Consult Danfoss for non
conformance to these guidelines. The housing must always be filled with hydraulic fluid. Rear case drain recommended
Auxiliary cavity pressure Will be equal to pump case pressure of rear housing.
Please verify mating pump shaft seal capability.
Physical Properties
Feature Unit Frame size
069 078 089 100 115 130 147 165 210 250
Displacem ent
cm3 [in3] 69 [4.21] 78 [4.76] 89 [4.76] 100 [4.76] 115.2
[7.03]
130.0 [7.93]
147 [8.97] 165 [10.07] 211.5
[12.91]
251.7 [15.36]
Oil volume liter [US
gal]
2.0 [0.5] 3.0 [ 0.8] 7.2 [ 1.9]
Mounting flange SAE flange, size C (SAE J 744) mounting pad SAE flange, size D (SAE J 744) mounting pad SAE flange, size E (ISO
3019-1 flange 177-4) mounting pad
Auxiliary mounting SAE A, SAE B, SAE B-B, SAE C SAE A, SAE B, SAE B-B,
SAE C, SAE D
SAE A, SAE B, SAE B-B, SAE C, SAE D, SAE E
Shafts Splined:
21-teeth 16/32, 23-teeth 16/32, 14-teeth 12/24
Splined: 27-teeth 16/32, 13-teeth 8/16
Splined: 13-teeth 8/16 17-teeth 8/16, 27-teeth 16/32
Suction port 1.625-12UN-2B [1 5/8-12UN-2B] Ø38 - 350 bar split
flange boss per ISO 6162 M12x1.75
Main port configuration Ø25.4 - 450 bar split flange boss per ISO 6162
M12x1.75
Ø31.5 - 450 bar split flange boss per ISO 6162 M12x1.75
Ø38 - 450 bar split flange boss per ISO 6162 M16x2
Case drain ports L1, L3 (SAE O-ring boss).
Case drain ports L2, L4 (SAE O-ring boss) prefered usage
0.875-12UNF-2B [7/8-12UNF-2B]
1.0625-12UNF-2B [1 1/16-12UNF-2B]
1.0625-12UNF-2B [1 1/16-12UNF-2B]
1.3175-12UNF-2B [1 5/16-12UNF-2B]
Port ISO 11926-1 - 1 5/16-12 (SAE O-ring boss) only L2 and L4
Other ports SAE O-ring boss. See installation drawings. Customer interface
threads
Metric fastener
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Technical Specifications
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 21
Operating Parameters
Feature Unit Frame size
069 078 089 100 115 130 147 165 210 250
Input speed Minimum min-1 (rpm) 500
Minimum for full performance
1200
Rated 3500 3200 3000
2600
Maximum 4000 3400 3100
2800
System pressure Working pressure bar [psi] 450 [6525]
Maximum pressure 480 [7000] Minimum low loop 10 [150]
Charge Pressure Minimum bar [psi] 10 [150] 16 [232] 18 [261]
Maximum 35 [508] 60 [870]
Control Pressure Minimum (at
corner for EDC and FNR)
bar [psi] 17 [ 247] 16 [232]
Minimum (at corner for NFPE)
25 (377)
Maximum 40 [580] 40 [580]
Charge pump inlet pressure
Rated bar (absolute)
[in Hg vacuum]
0.7 [9]
Minimum (cold start)
0.2 [24]
Maximum bar [psi] 4.0 [58]
Case pressure Rated bar [psi] 3.0 [40]
Maximum 5.0 [75]
Fluid Specifications
Feature Unit Value
Viscosity Minimum mm2/sec [SUS] 7 [49]
Recommended Range 12-80 [66-370] Maximum 1600 [7500]
Temperature Range Minimum OC [OF] -40 [-40]
Rated 104 [220] Maximum intermittent 115 [240]
Filtration (recommended minimum)
Cleanliness per ISO 4460 22/18/13 Efficiency (charge pressure filtration) b-ratio b
15-20
= 75 (b10≥10)
Efficiency (suction and return line filtration) b
35-45
= 75 (b10≥2)
Recommended inlet screen mesh size mm 100 - 125
Ratings and data are based on operation with premium petroleum-based hydraulic fluids containing oxidation, rust, and foam inhibitors.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Technical Specifications
22 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Fluid and Filter Recommendations
To ensure optimum life, perform regular maintenance of the fluid and filter. Contaminated fluid is the main cause of unit failure. Take care to maintain fluid cleanliness when servicing.
Check the reservoir daily for proper fluid level, the presence of water, and rancid fluid odor. Fluid contaminated by water may appear cloudy or milky or free water may settle in the bottom of the reservoir. Rancid odor indicates the fluid has been exposed to excessive heat. Change the fluid and correct the problem immediately if these conditions occur.
Inspect vehicle for leaks daily. Change the fluid and filter per the vehicle/machine manufacturer’s recommendations or at intervals shown in the table. We recommend first fluid change at 500 hours.
High temperatures and pressures will result in accelerated fluid aging. More frequent fluid changes may be required.
Change the fluid more frequently if it becomes contaminated with foreign matter (dirt, water, grease, etc.) or if the fluid is subjected to temperature levels greater than the recommended maximum. Dispose of used hydraulic fluid properly. Never reuse hydraulic fluid.
Change filters with the fluid or when the filter indicator shows it’s necessary. Replace all fluid lost during filter change.
For detailed filtration information, see Danfoss publication 520L0463 Fluids and Filtration. For information on biodegradable fluids see Danfoss publication 520L0465 Biodegradable Hydraulic Fluids.
Fluid and Filter Change Interval
Reservoir type Max oil change interval
Sealed 2000 hours Breather 500 hours
Hazardous Material
W
Warning
Hydraulic fluid contains hazardous material. Avoid contact with hydraulic fluid. Always dispose of used hydraulic fluid according to state and federal environmental regulations.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Fluid and Filter Maintenance
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 23
Port Locations and Gauge Installation
The following table and drawing show the port locations and gauge sizes needed. When testing system pressures, calibrate pressure gauges frequently to ensure accuracy. Use snubbers to protect gauges.
Port Information
Port identifier Port size Wrench size Reading Gauge size, bar [psi] Displacement
L1, L3 7/8-14 UNF 2B 3/8 internal hex Case drain 10 [100] 069/078 L2, L4 1 1/16-12 UNF 2B 9/16 internal hex Case drain 10 [100] 069/078/089/100 L1, L3 1 1/16-12 UNF 2B 9/16 internal hex Case drain 10 [100] 089/100/115/
130/147/165 L2, L4 1 5/16-12 UNF 2B 5/8 internal hex Case drain 10 [100] 115/130/147/165 MA, MB 9/16-18 UNF 1/4 internal hex System pressure 600 [10,000] 115/130/147/165/210/250 M3 9/16-18 UNF 2B 1/4 internal hex Charge pressure- after filter 50 [1000] 115/130/147/165/210/250 M4, M5 7/16-20 UNF 2B 3/16 internal hex Servo pressure 50 [1000] 115/130/147/165/210/250 M6 9/16-18 UNF 2B 1/4 internal hex Charge pressure - pre
integrated filter
50 [1000] 115/130/147/165/210/250
L2, L4
1 5/8-12 UNF 5/8 internal hex Case drain 10 [100]
210/250 A;B 24.5 mm; M12 x
1.75; 20 min. full thread depth; Recommended screw in depth 1.5 x thread dia.
System Ports A and B 450 bar, Split flangeboss per ISO 6162
600 [10,000] 069/078/089/100/115/130
A;B 31.5 mm; M12 x
1.75; 20 min. full thread depth; Recommended screw in depth 1.5 x thread dia.
System Ports A and B 450 bar, Split flangeboss per ISO 6162
600 [10,000] 147/165
A;B 38 mm; M12 x 1.75;
20 min. full thread depth; Recommended screw in depth 1.5 x thread dia.
System Ports A and B 450 bar, Split flangeboss per ISO 6162
600 [10,000] 210/250
S Charge Pump Inlet N/A
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Pressure Measurements
24 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Port locations
M6
MB
MA
M3
M5
L3
L1
L2
System Port
B
M4
S
System Port A
L4
G302
L2
D065
P106033
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Pressure Measurements
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 25
General
Follow this procedure when starting-up a new pump installation or when restarting an installation in which the pump has been removed and re-installed on a machine. Ensure pump has been thoroughly tested on a test stand before installing on a machine.
W
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. To protect against unintended movement, secure the machine or disable/disconnect the mechanism while servicing.
Prior to installing the pump, inspect for damage that may have occurred during shipping.
Start-Up Procedure
1. Ensure that the machine hydraulic oil and system components (reservoir, hoses, valves, fittings, and
heat exchanger) are clean and free of any foreign material.
2. Install new system filter element(s) if necessary. Check that inlet line fittings are properly tightened
and there are no air leaks.
3. Install the pump. Install a 50 bar [1000 psi] gauge in the charge pressure gauge port M
4. Fill the housing by adding filtered oil in the upper case drain port. If the control is intalled on top,
open the construction plug in the top of the control to assist in air bleed.
5. Fill the reservoir with hydraulic fluid of the recommended type and viscosity. Use a 10-micron filler
filter. Fill inlet line from reservoir to pump.
6. Disconnect the pump from all control input signals.
7. Close construction plug removed in Step 4.
C
Caution
After start-up the fluid level in the reservoir may drop due to system components filling. Damage to hydraulic components may occur if the fluid supply runs out. Ensure reservoir remains full of fluid during start-up.
Air entrapment in oil under high pressure may damage hydraulic components. Check carefully for inlet line leaks.
Do not run at maximum pressure until system is free of air and fluid has been thoroughly filtered.
8. Use a common method to disable the engine to prevent it from starting. Crank the starter for several
seconds. Do not to exceed the engine manufacturer’s recommendation. Wait 30 seconds and then crank the engine a second time as stated above. This operation helps remove air from the system lines. Refill the reservoir to recommended full oil level.
9. When the gauge begins to register charge pressure, enable and start engine. Let the engine run for a
minimum of 30 seconds at low idle to allow the air to work itself out of the system. Check for leaks at all line connections and listen for cavitation. Check for proper fluid level in reservoir.
10. When adequate charge pressure is established (as shown in model code), increase engine speed to
normal operating rpm to further purge residual air from the system.
11. Shut off engine. Connect pump control signal. Start engine, checking to be certain pump remains in
neutral. Run engine at normal operating speed and carefully check for forward and reverse control operation.
12. Continue to cycle between forward and reverse for at least five minutes to bleed all air and flush
system contaminants out of loop.
Normal charge pressure fluctuation may occur during forward and reverse operation.
13. Check that the reservoir is full. Remove charge pressure gauge. The pump is now ready for operation.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Initial Startup Procedures
26 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Overview
This section provides troubleshooting steps to follow if you are having problems with your machine. Follow the steps as listed until you solve the problem. Some of the troubleshooting items are system specific. We reference another section in this manual if more information is available. Always observe the safety precautions listed in the Introduction section and precautions related to your specific equipment.
Safety Precautions
C
Caution
High inlet vacuum causes cavitation which can damage internal pump components.
W
Warning
Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin causing serious injury and/or infection. Relieve pressure in the system before removing hoses, fittings, gauges, or components.
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. To protect against unintended movement, secure the machine or disable/disconnect the mechanism while servicing.
C
Caution
Contamination can damage internal components and void the manufacturer’s warranty. Take precautions to ensure system cleanliness when removing and reinstalling system lines
W
Warning
Hydraulic fluid contains hazardous material. Avoid contact with hydraulic fluid. Always dispose of used hydraulic fluid according to state, and federal environmental regulations.
Electrical Troubleshooting
Item Description Action
Control operates pump in one direction only.
Control coil failure Measure resistance at coil pins. Resistance should be 14.20
ohms (24V) or 3.66 ohms (12V) at 20°C [70°F]. Replace coil No pump function No power to controller Restore power to controller. Erratic pump function Electrical connection to pump is bad. Disconnect connection, check wires, reconnect wires. Filter bypass indicator switch Filter bypass indicator switch may be bad. Check/replace filter switch. Add gauge to filter bypass port
to verify proper fluid flow and verify switch operation by
measuring resistance: open resistance>=510 ohms, closed
resistance<=122 ohms
If available, use manual override to check proper pump operation and verify electrical problem.
System Operating Hot
Item Description Action
Oil level in reservoir. Insufficient hydraulic fluid will not meet cooling demands
of system.
Fill reservoir to proper level.
Heat exchanger. Heat exchanger is not sufficiently cooling the system. Check air flow and input air temperature for heat
exchanger. Clean, repair or replace heat exchanger.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Troubleshooting
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 27
Item Description Action
Charge pressure. Low charge pressure will overwork system. Measure charge pressure. Inspect and adjust or replace
charge relief valve. Inspect charge pump. Repair or replace charge pump.
Charge pump inlet vacuum. High inlet vacuum will overwork system. A dirty filter will
increase the inlet vacuum. Inadequate line size will restrict flow.
Check charge inlet vacuum. If high, inspect inlet filter and replace as necessary. Check for adequate line size, length or other restrictions.
System relief pressure settings
If the system relief valves are worn, contaminated, or valve settings are too low, the relief valves will be overworked.
Verify settings of pressure limiters and high pressure relief valves and adjust or replace valves as necessary.
System pressure. Frequent or long term operation over system relief setting
will create heat in system.
Measure system pressure. If pressure is too high, reduce loads.
Integral Filter Bypass
Item Description Action
Filter bypass activated Filter is plugged causing fluid to bypass filter. Replace filter. Check that bypass switch indicates proper
operation after filter is replaced.
Filter bypass indicator switch Filter bypass indicator switch is indicating wrong bypass
situation.
Check/replace switch. open>=510 ohms closed<=122 ohms
Neutral Difficult or Impossible to Find
Item Description Action
Input to pump control Input to control module is operating
improperly.
Disconnect input and check to see if pump comes back to neutral. If Yes, input fault, replace/repair external controller. If No, go to next step.
Neutral Neutral set improperly Shunt servo gauge ports (M4 and M5) together with
external hose and see if pump comes back to neutral. If Yes: Control neutral improperly set. If neutral is still impossible to set, balance the swashplate (see Mechanical Neutral Adjustment). If you still cannot set neutral, replace the control.
System Will Not Operate in Either Direction
Item Description Action
Oil level in reservoir. Insufficient hydraulic fluid to supply system loop. Fill reservoir to proper level. Pump control orifices Control orifices are blocked. Clean control orifices. Pump control screens Control screens are blocked. Replace control screens. Only a Danfoss Authorized Service
Center may remove the unit’s endcap without voiding the warranty.
Bypass function open If bypass function is open, the system loop will be
depressurized.
Close bypass valves. Replace high pressure relief valve if defective.
Low charge pressure with pump in neutral
Low charge pressure insufficient to recharge system loop. Measure charge pressure with the pump in neutral. If
pressure is low, go to Pump charge relief valve.
Low charge pressure with pump in stroke
Low charge pressure resulting from elevated loop leakage. Insufficient control pressure to hold pump in stroke.
Deadhead the pump to isolate it from the motor.With pump in partial stroke and engaged for only a few seconds, check pump charge pressure. Low charge pressure indicates a malfunctioning pump. Continue to next step. Good charge pressure indicates a malfunctioning motor or other system component. Check motor charge relief operation (if present).
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Troubleshooting
28 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Item Description Action
Pump charge relief valve A pump charge relief valve that is leaky, contaminated, or
set too low will depressurize the system.
Adjust or replace pump charge relief valve as necessary.
Charge pump inlet filter A clogged filter will under supply system loop. Inspect filter and replace if necessary. Charge pump A malfunctioning charge pump will provide insufficient
charge flow.
Repair or replace the charge pump.
System pressure Low system pressure does not provide enough power to
move load.
Measure system pressure. Continue to next step.
High pressure relief or pressure limiter valves
Defective high pressure relief or pressure limiter valves cause system pressure to be low.
Repair or replace high pressure relief or pressure limiter
valves. Input to control Input operating improperly Repair/replace control.
System Noise or Vibration
Item Description Action
Reservoir oil level Low oil level leads to cavitation. Fill reservoir. Aeration of the oil/pump
inlet vacuum
Air in system decreases efficiency of units and controls. Excessive noise, foaming oil, and hot oil all indicate air in system.
Find location where air is entering into the system and
repair. Check that inlet line is not restricted and is proper
size. Cold oil If oil is cold, it may be too viscous for proper function and
pump cavitates.
Allow the oil to warm up to its normal operating
temperature with engine at idle speed. Pump inlet vacuum High inlet vacuum causes noise/cavitation. Check that inlet line is not restricted and is of proper size.
Check filter and bypass switch. Shaft couplings A loose shaft coupling will cause excessive noise. Replace loose shaft coupling.. Shaft alignment Misaligned shafts create noise. Align shafts. Charge/system relief valves Unusual noise may indicate sticking valves and possible
contamination.
Clean/replace valves and test pump.
Sluggish System Response
Item Description Action
Oil level in reservoir Low oil level causes sluggish response. Fill reservoir. High pressure relief valves/
pressure limiter settings
Incorrect pressure settings affects system reaction time. Adjust or replace high pressure relief valves.
Low prime mover speed Low engine speed reduces system performance. Adjust engine speed. Charge pressure Incorrect pressure affects system performance. Measure and adjust charge pressure relief or replace charge
pump. Air in system Air in system produces sluggish system response. Fill tank to proper level. Cycle system slowly for several
minutes to remove air from system. Contaminated control
orifices
Control orifices are plugged. Clean control orifices.
Contaminated control screens
EDC supply screen is plugged. Replace control screens. Only a Danfoss Authorized Service
Center may remove the unit’s endcap without voiding the
warranty. Pump inlet vacuum Inlet vacuum is too high resulting in reduced system
pressure.
Measure charge inlet vacuum. Inspect line for proper sizing.
Replace filter. Confirm proper bypass operation.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Troubleshooting
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 29
Transmission Operates Normally in One Direction Only
Item Description Action
Input to pump control. Input to control module is operating improperly. Check control input and repair or replace as necessary. Control orifices Control orifice(s) are blocked. Clean control orifices. Control screens Control screen(s) are blocked. Replace control screens. Only a Danfoss Authorized Service
Center may remove the unit’s endcap without voiding the warranty.
Exchange system pressure limiters
Exchanging the pressure limiter valves will show if the problem is related to the valve function.
If the problem changes direction, replace the valve that does not operate correctly.
Exchange high pressure relief valves
Exchanging the high pressure relief valves will show if the problem is related to the valve function.
If the problem changes direction, replace the valve that does not operate correctly.
Servo pressure low or decaying
Damaged servo seals may prevent servo piston from stroking the pump.
Check for torn/missing servo seals. Replace and retest. Only a Danfoss Authorized Service Center may remove the servo piston without voiding the warranty.
Bypass function open Open bypass will cause one or both directions to be
inoperative.
Close bypass function.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Troubleshooting
30 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
This section offers instruction on inspection and adjustment of pump components. Read through the entire topic before beginning a service activity.
Refer to Pressure Measurements for location of gauge ports and suggested gauge size.
Standard Procedures
C
Caution
Contamination can damage internal components and void your warranty. Take precautions to ensure system cleanliness when removing and reinstalling system lines
1. With the prime mover off, thoroughly clean the outside of the pump.
2. If removing the pump, tag each hydraulic line. When you disconnect hydraulic lines, cap them and
plug each open port to prevent contamination.
3. Ensure the surrounding area is clean and free of contaminants like dirt and grime.
4. Inspect the system for contamination.
5. Check the hydraulic fluid for signs of contamination: oil discoloration, foam in the oil, sludge, or metal
particles.
6. If there are signs of contamination in the hydraulic fluid, replace all filters and drain the hydraulic
system. Flush the lines and refill the reservoir with the correct filtered hydraulic fluid.
7. Before re-installing the pump, test for leaks.
Charge Pressure Relief Valve Adjustments
This procedure explains how to check and adjust the charge pressure relief valve.
1. Install a 50 bar [1000 psi] pressure gauge in charge pressure gauge port M3. Install a 10 bar [100 psi]
gauge at case drain port L1, L2, L3, or L4. Operate the system with the pump in neutral (zero displacement) when measuring charge pressure.
2. The table shows the acceptable pump charge pressure range for some nominal charge relief valve
settings (refer to model code located on serial number plate). These pressures assume 1800 min-1 (rpm) pump speed and a reservoir temperature of 50°C [120°F], and are referenced to case pressure.
Charge Pressure Adjustment
Case drain port L4
Charge pressure gauge port M3
Adjustment screw 5 mm
Locknut 13 mm
Case drain port L2
P104466
12 N•m [9 lbf•ft]
Optional construction port M14
0 - 10 bar [0 - 100 psi] 9/16 (069/078) / 5/8 in (147/165/210/250) 70 N•m [52 lbf•ft] (078) 150 N•m [110 lbf•ft] (147/165/210/250)
0 - 10 bar [0 - 100 psi] 3/8 in (069/078) / 9/16 in (089/100/147/165) 5/8 in (210/250) 70 N•m [52 lbf•ft]
0 - 10 bar [0 - 100 psi] 3/16 in
0 - 50 bar [0 - 1000 psi] 1/4 in
12 N•m [9 lbf•ft]
24 N•m [18 lbf•ft]
Listed pressures assume a pump speed of 1800 min¯¹ (rpm). At higher pump speeds (with higher charge flows) the charge pressure will rise over the rated setting.
Depending on the pressure rating, the charge pressure relief valve may have one or two springs.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 31
Charge Pressure Ranges
Model code Actual charge pressure*
20 20 bar [290 psi ] ± 1.5 bar [21.8 psi] 24 24 bar [348 psi] ± 1.5 bar [21.8 psi] 26 26 bar [377 psi] ± 1.5 bar [21.8 psi] 30 30 bar [435 psi] ± 1.5 bar [21.8 psi] * This is the actual charge pressure port gauge reading minus the case pressure port gauge reading. Factory set
at 1800 min-1 (rpm) with a reservoir temperature of 50° C [120° F].
3. Loosen the locknut and turn the adjusting screw clockwise to increase the setting; counterclockwise
to decrease it. The table gives approximate adjustment per turn.
Number of springs Change per turn
1 Spring consult factory 2 Springs 3.9 bar [56.6 psi]
4. While holding the adjusting screw, torque locknut to 12 N•m [9 lbf•ft].
5. When you achieve the desired charge pressure setting, remove the gauges and plug the ports.
Pressure Limiter Adjustment
Lock motor output shaft to adjust the pressure limiter setting. Lock the vehicle’s brakes or rigidly fix the work function so it cannot rotate.
1. Install 600 bar [10,000 psi] pressure gauges in the high pressure gauge ports (MA and MB). Install a 50
bar [1000 psi] pressure gauge in the charge pressure gauge port (M3).
Ensure charge pressure is properly set before checking pressure limiter.
If you change pressure limiter settings, you must also change the HPRV valve to maintain proper PL function. Refer to table on next page for corresponding settings.
Subtract charge pressure from system pressure to get correct system pressure.
Pressure Limiter Adjustment
System pressure gauge port MB
(on bottom)
Pressure limiter adjusting screw
Pressure limiter locknut
P104 465E
System pressure gauge port MA
0 - 600 bar [0 - 10,000 psi] 1/4 in 24 N•m [18 lbf•ft]
0 - 600 bar [0 - 10,000 psi] 1/4 in 24 N•m [18 lbf•ft]
Charge pressure gauge port M3
0 - 50 bar [0 - 1000 psi] 1/4 in 24 N•m [18 lbf•ft]
HPRV
P106351
L010 Adjusting screw 5 mm internal hex
L024 Locking nut 16 mm L028 Plug (special) 19 mm
L012 Cartridge 22 mm
115/130/147/165/210/250
L028 Adjusting screw
8 mm internal hex
L024 Locking nut 14 mm
L012 Cartridge 22 mm
069/078/089/100 Pressure limiter
Fastener
Torque
N•m [lbf•ft]
L010
L024
L028
L012
N/A
20 [15]
68 [50]
70 [52]
Fastener
Torque
N•m [lbf•ft]
L028
L024
L012
N/A
20 [15]
30 [22]
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
32 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Pressure Limiter Valve Adjustment
P106 250E
Port B System pressure
Port A System pressure
Counterclockwise rotation *
Pressure limiter valves
Controls Port B
Controls Port A
Port B System pressure
Port A System pressure
Clockwise rotation *
Pressure limiter valves
Controls Port A
Controls Port B
* Clockwise rotation as seen from
shaft end of pump
*
*
* Counterclockwise rotation as seen
from shaft end of pump
Endcaps are different for clockwise and counterclockwise rotation.
2. Start the prime mover and operate at normal speed.
3. Use a 17mm wrench to loosen the locking nut (L024).
4. Activate the control input until pressure in the high side of the system loop stops rising. This pressure
is the PL setting.
5. Return the pump to neutral and adjust the PL setting using an internal hex wrench. Wrench size is in
the diagram on the previous page. Turn the adjusting screw clockwise to increase the PL setting, counterclockwise to decrease it. The adjustment is very sensitive. Change per turn is approximately 150 bar [2176 psi].
Change per turn is 150 bar/rev [2176 psi/rev].
The model code on the serial plate gives the factory setting of the PL (Pressure Limiter). The PL setting is referenced to charge pressure. Subtract charge pressure from system pressure gauge readings to compute the effective PL setting.
6. Repeat steps four and five until you reach the desired PL setting. After adjustment, torque the locknut
(L024) to 20 N•m [15 lbf•ft]. Do not over torque.
7. Shut down the prime mover. Remove gauges and replace plugs.
Pressure Limiter Settings
Pressure limiter setting HPRV setting
150 200 180 230 200 250 230 280 250 300 280 330 300 350 330 380 350 400 380 420
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 33
Pressure Limiter Settings (continued)
Pressure limiter setting HPRV setting
400 450 410 420 430 480 440 450 460 510 470 480
Engaging the Bypass Function
Use this procedure to bypass the pump to allow moving the vehicle/machine short distances when you cannot start the prime mover.
C
Caution
It is possible to damage the drive motor(s) by operating in bypass mode without charge pressure. Move the vehicle/machine at a speed not more than 20% of maximum for a duration not exceeding 3 minutes.
1. To open the HPRVs (L150), rotate three revolutions counterclockwise. Do not rotate more than 3
revolutions, leakage will result.
2. To close the HPRVs, rotate them clockwise until seated. See table above for torque values.
3. If machine is towable with HPRVs opened three turns and if wheels are locked (not towable) with
HPRV valves closed, bypass function is working correctly.
Engaging the Bypass Function
L150
P106 649E
HPRV Wrench Size and Torque Values
Displacement Wrench size and torque
069/078/089/100 22 mm - 70 N•m [52 lbf-ft] 115/130/147/165/210/250 30 mm - 110 N•m [81 lbf-ft]
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
34 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Displacement Limiter Adjustment
If your pump has displacement limiters, you will find them on either servo cover. You can limit forward and reverse displacement independently.
Displacement limiters are not pre-set by the factory. We install them as far as possible without contacting the servo piston. Limiting displacement requires clockwise adjustment of the limiting screw.
C
Caution
Before adjusting the displacement limiter, mark the position of the servo cylinder. Be sure the servo cylinder does not turn when setting the displacement limiter locknut.
1. Loosen the lockingnut.
2. Rotate the adjusting screw to achieve the desired maximum displacement. Set the adjusting screw
against the servo piston by feel before counting turns. Refer to the table below for change per turn. Clockwise rotation decreases displacement, counterclockwise rotation increases it. Adjustment is possible from zero to maximum.
3. After establishing the desired maximum displacement setting, hold the adjusting screw while
torquing the locknut to the value in the table below.
4. Test operation of the vehicle/machine to verify proper maximum speed of vehicle/work function.
Displacement Limiter Adjustment
P104 469E
Limiting Screw
Locknut
(see table)
(see table)
Displacement Limiter Adjustment Data
Displacement Locknut wrench size and
torque
Adjusting screw wrench size
Approximate displacement change per revolution of adjusting screw
069 13 mm - 24 N•m [18 lbf-ft] 4 mm 6.0 cm3/turn [0.366 in3/turn] 078 13 mm - 24 N•m [18 lbf-ft] 4 mm 7.4 cm3/turn [0.452 in3/turn] 089 17 mm - 48 N•m [35 lbf-ft] 5 mm 9.3 cm3/turn [0.57 in3/turn] 100 17 mm - 48 N•m [35 lbf-ft] 5 mm 10.7 cm3/turn [0.65 in3/turn] 115 22 mm - 80 N•m [59 lbf-ft] 6 mm 10.8 cm3/turn [0.66 in3/turn] 130 22 mm - 80 N•m [59 lbf-ft] 6 mm 12.2 cm3/turn [0.745 in3/turn] 147 22 mm - 80 N•m [59 lbf-ft] 6 mm 12.4 cm3/turn [0.757 in3/turn] 165 22 mm - 80 N•m [59 lbf-ft] 6 mm 13.9 cm3/turn [0.848 in3/turn]
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 35
Displacement Limiter Adjustment Data (continued)
Displacement Locknut wrench size and
torque
Adjusting screw wrench size
Approximate displacement change per revolution of adjusting screw
210
22 mm - 80 N•m [59 lbf-ft]
6 mm
17.4 cm3/turn [1.06 in3/turn]
250
22 mm - 80 N•m [59 lbf-ft]
6 mm
20.7 cm3/turn [1.26 in3/turn]
Control Neutral Adjustment
All functions of the Electric Displacement Control (EDC), are preset at the factory. If necessary, adjust the pump to neutral with the pump running on a test stand or on the vehicle/machine with the prime mover operating. If adjustment fails to give satisfactory results, you may need to replace the control or coils. See Minor repair for details.
W
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. To protect against unintended movement, secure the machine or disable/disconnect the mechanism while servicing.
1. Install a 50 bar [1000 psi] gauge in each of the two servo gauge ports (M4 and M5). Disconnect the
external control input (electrical connections) from the control. Start the prime mover and operate at normal speed.
2. Use a 4mm internal hex wrench to hold the neutral adjusting screw (D015) stationary while loosening
the locknut (D060) with a 13mm wrench.
3. Observe pressure gauges. If necessary, turn adjusting screw (D015) to reduce pressure differential.
EDC adjustment is very sensitive. Be sure to hold the hex wrench steady while loosening the locknut. Total adjustment is less than 120 degrees.
Control Adjustment
Locknut 13 mm
Adjusting screw 4 mm
P104 970
12 N•m [9 lbf•ft]
Servo pressure gauge port M5
Servo pressure gauge port M4
0 - 50 bar [0 - 1000 psi] 1/8 in 5 N•m [4 lbf•ft]
0 - 50 bar [0 - 1000 psi] 1/8 in 5 N•m [4 lbf•ft]
4. Rotate the neutral adjusting screw (D015) clockwise until the pressure increases on the gauge. Note
the angular position of the wrench. Then rotate the neutral adjusting screw counterclockwise until the pressure increases by an equal amount on the other gauge. Again note the angular position of the wrench.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
36 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
5. Rotate the neutral adjusting screw clockwise half the distance between the wrench positions noted
above. The gauges should read the same pressure, indicating that the control is in its neutral position.
6. Hold the neutral adjusting screw stationary and tighten the locknut (D060). Torque to 12 N•m [9
lbf•ft]. Do not over torque the nut.
7. When the neutral position is set, stop the prime mover, remove the gauges, and install the gauge
port plugs. Reconnect the external control input.
A small pressure differential of 1.5 bar [22 psi] or less is acceptable. Zero differential is usually not possible.
Neutral Adjustment (EDC) (bottom view)
Solenoid shaft
Feedback pin
Adjusting screw (cam)
P106 046E
Maximum adjustment less than 120°
Control spool
Illustration shows how cam on adjusting pin rotates to adjust for neutral position after pump is re­installed.
Mechanical Neutral Adjustment
Mechanical neutral is set with the pump running at 1800 min¯¹ (rpm). To set neutral, you must stroke the pump in each direction. You can do this with a small movement of the eccentric screw on EDC controls, however non-feedback controls (NFPE/FNR/FDC) lack this mechanism. To stroke a pump with non­feedback control, you must provide a 100 Hz PWM signal to the control solenoids. Refer to the H1 Pumps Technical Information Manual 11009999 for signal specifications. If you perform this adjustment with the pump installed in a vehicle or machine, safely elevate the wheels or disconnect the mechanism to allow safe operation during adjustment.
This procedure details setting neutral for the pump. Alternate M4/M5 and MA/MB to zero out forward and reverse directions of the unit Refer to the drawing on the next page to identify all ports. The control solenoids C1 and C2 are marked on the control.
While performing this adjustment, you will monitor the following pressures.
Servo pressure at M4 and M5
System pressure at MA and MB
Pressure differential between M4 and M5 (optional)
Pressure differential between A and B (optional)
Refer to Pressure measurement and the illustration on the next page for gauge port locations and information.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 37
Pump setup
1. Attach a 50 bar [1000 psi] gauge to each servo pressure port M4 and M5.
2. Attach a 600 bar [10 000 psi] gauge to each system pressure port (MA and MB).
3. Remove servo cylinder locking screws (E350) and plates (E300) from both sides of the pump.
4. Disconnect the control solenoids from the vehicle wiring harness.
5. If using a PWM signal to set mechanical neutral, connect the control solenoids C1 and C2 to the signal
source. Ensure the source supplies no current to the solenoids until required in the following procedure.
The figure below shows the locations of sysem and gage ports you use when adjusting the servo neutral postion.
System Pressure Gage Port Locations
System Port B
Servo pressure port M4
System Port A
Servo pressure port M4
Servo pressure port M5
Solenoid C1
Solenoid C2
Gauge port MB system pressure
Gauge port MA system pressure
P106 489E
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
38 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Servo Adjustment
1. Run prime mover at 1800 min¯¹(rpm).
2. If using a PWM signal, ensure the signal is off. Check the servo pressure gauges. Ensure the differential
between M4 and M5 is less than 1.5 bar [22 psi].
3. Using a 3/4 in hex deep socket, unthread both servo cylinders 2-3 turns. This step ensures the servo
cylinders have no contact with the servo piston.
4. Stroke the pump by turning the control eccentric screw (or supplying current to solenoid C1) until the
servo pressure at port M4 is 1 to 2 bar [14– 29 psi] greater than at port M5 and the system pressure gauges indicate displacement. Pressure should be greater at port MA for clockwise rotation, or MB for counterclockwise rotation. This also indicates the servo piston is in contact with the servo cylinder on side M5.
5. Slowly thread the servo cylinder on the M5 side in until the system pressure differential starts to
decrease. Maintain servo pressure differential between 1-2 bar [14-29 psi] during this step. Continue turning the servo cylinder in until the system pressure differential (between ports MA/MB) is less than
1.5 bar [22 psi]. This procedure sets the servo and swashplate to mechanical neutral on the M5 side.
6. To complete setting neutral, repeat steps 1-5 but stroke the pump in the opposite direction by
turning the eccentric screw in the opposite direction, or by supplying current to solenoid C2. Reverse gauge locations (M4 for M5, MB for MA) from those stated above since the pump is now stroking the other direction.
7. Remove all gauges and replace gauge port plugs. You can find wrench sizes and plug torques in the
Plug Size and Torque Chart.
Servo Adjustment
E350
Servo can locking bolt
E300
Servo can locking plate
P106 490E
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Adjustments
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 39
Standard Procedures, Removing the Pump
Before working on the pump, thoroughly clean the outside. If the pump has an auxiliary pump attached, remove both pumps as a single unit. Tag and cap all hydraulic lines as they are disconnected, and plug all open ports to ensure that dirt and contamination do not get into the system.
C
Caution
Contamination can damage internal components and void the manufacturer’s warranty. Take precautions to ensure system cleanliness when removing and installing system lines.
Disassembly
1. With the prime mover off, thoroughly clean all dirt and grime from the outside of the pump.
2. Tag, disconnect, and cap each hydraulic line connected to the pump. As hydraulic lines are
disconnected, plug each open port, to ensure that dirt and contamination do not get into the pump.
3. Remove the pump and its auxiliary pump (if applicable) as a single unit.
Be careful, do not damage solenoids and electrical connections when using straps or chains to support the pump.
Inspection
1. Ensure the work surface and surrounding area are clean and free of contaminants such as dirt and
grime.
2. Inspect the system for contamination.
3. Look at the hydraulic fluid for signs of system contamination, oil discoloration, foam in the oil, sludge,
or metal particles.
Reassembly
1. Before replacing the pump, replace all filters and drain the hydraulic system. Flush the system lines
and fill the reservoir with the correct, filtered hydraulic fluid.
2. Fill the pump with clean, filtered hydraulic fluid.
3. Attach the pump to the prime mover. Torque mounting screws according to the manufacturers
recommendation.
4. Replace all hydraulic lines. Ensure the charge inlet line is filled with fluid.
EDC Control
Removal
Refer to exploded diagram, next page.
1. Using a 5 mm internal hex wrench, remove the six cap screws (D250).
2. Remove the control module and gasket (D150). Discard the gasket.
3. If necessary, remove orifices (F100) using a 3 mm internal hex wrench. Tag and number them for
reinstallation.
4. If screen (D084) is clogged, use a hook to remove retaining ring (D098) and screen. Discard screen and
replace with new screen.
Inspection
Inspect the machined surfaces on the control and top of the pump. If you find any nicks or scratches, replace the component.
Reassembly
Ensure you install dowel pins (D300) in housing before installing control.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
40 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
1. Install a new gasket (D150).
Proper Screen Orientation
P106 618E
D084
D084
Incorrect screen orientation
Correct screen orientation
D094
2. If you removed screen (D084), install a new one. Install with the mesh facing outward (see drawing).
Install retaining ring (D098).
3. If previously removed, install orifices (F100) using a 3 mm internal hex wrench. Torque to 2.5 N•m [1.8
lbf•ft].
4. Install the control module and six cap screws (D250).
5. Using a 5 mm internal hex wrench, torque the cap screws (D250) to 13.3 N•m [9.8 lbf•ft].
Remove plug on top of control to ensure the swashplate feedback pin is properly positioned in the center of the control module when installing control.
Control Module and Solenoid Removal/Installation
P106 650E
D025
D1
D025A
D025A
D150
5 mm
13.5 N•m [9.8 lbf•ft]
D250
D050 (3X)
D050 (3X)
D084
5 N•m [4 lbf•ft]
4 mm
5 N•m
[4 lbf•ft]
4 mm
F100 (2X)
D300 (2X)
2.5 N•m [1.8 lbf•ft]
3 mm
D098
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 41
Torque Sequence
2
3
4
56
1
P106231
Control Solenoids
Removal
1. Disconnect electrical connection and remove the three cap screws (D050) using a 4 mm internal hex
wrench.
2. Remove the solenoid (D025) and O-ring (D025A). Discard the O-ring.
3. If necessary, remove the coil using a 12 point 26 mm socket.
Inspection
Inspect the machined surface on the control. If you find any nicks or scratches, replace the component.
Reassembly
1. Lubricate new O-ring (D025A) using petroleum jelly and install.
2. Install solenoid with three cap screws (D050) using a 4 mm internal hex wrench. Torque screws to 5
N•m [4 lbf•ft].
3. Install coil using a 12 point 26 mm socket. Torque coil nut to 5 N•m [3.7 lbf•ft].
4. Reconnect electrical connections and test the pump for proper operation.
MDC Control
Removal
Refer to exploded diagram, below.
1. Using a 5 mm internal hex wrench, remove the six cap screws (D250).
2. Remove the control module and gasket (D150). Discard the gasket.
3. If necessary, remove servo orifices (F00A, F00B), supply orifice (F00P), and tank orifices (F00T) using a
3 mm internal hex wrench. Tag and number them for reistallation.
4. If screen (D084) is clogged, use a hook to remove the retaining ring (D098) and the screen. Discard
the screen and replace with a new screen.
5. Before removing the control, note the position of the control lever for reassembly.
C
Caution
Do not disassemble the control, otherwise the functionality of the control and the neutral position of the pump can be lost!
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
42 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
MDC illustration - single pumps
P108784
D250
D065
D735
D300 (2X)
D200
D150
F00A
MDC with CCO
MDC with neutral start switch
MDC with neutral start switch and CCO
F00T
F00B
F00P
D692
D693
D750
D065
D250
D81
D80
D750
D065
D250
D81
D80
D250
D065
D750
D751
D751
D084
D098
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 43
MDC Legend - single pumps
Wrench size and torque
Item Description Wrench size Torque
D065 O-ring plug 3/16 internal hex 12 N•m [9 lbf•ft] D084 screen - ­D098 ring - ­D200 feedback pin 13 mm deep well socket 22.5-27.5 Nm [16.6-20.3 lbf•ft] D250 cap screw 5 mm internal hex 13.3 Nm [9.8 lbf•ft] D80 solenoid - ­D81 Oring - ­D750 neutral start switch - ­D751 Oring - ­D735 plug 3/4 inch 30 Nm [22 lbf•ft] F00A servo orifice 3 mm internal hex 2.5 Nm [1.8 lbf•ft] F00B servo orifice 3 mm internal hex 2.5 Nm [1.8 lbf•ft] F00P supply orifice 3 mm internal hex 2.5 Nm [1.8 lbf•ft] F00T tank orifice 3 mm internal hex 2.5 Nm [1.8 lbf•ft]
Inspection
Inspect the machined surfaces on the control and top of the pump. If you find any nicks or scratches, replace the component.
Reassembly
Ensure you install dowel pins (D300) in the housing before installing the control.
1. Install a new gasket (D150).
2. Install dowel pins (D300) in the housing.
W
Warning
If the feedback pin comes off during operation, the pump will lose controllability causing a potentially hazardous situation. Insure feedback pin is properly torqued before continuing with reassembly.
3. If you removed screen (D084), install a new one. Install it with the mesh facing outward (see drawing).
Install retaining ring (D098).
MDC - Proper screen orientation
D084
D084
In
co
r
r
e
c
t sc
r
een
o
r
ie
n
t
a
tion
C
o
r
r
e
c
t sc
r
een
o
r
ie
n
t
a
tion
D098
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
44 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
4. If previously removed, install orifices using a 3 mm internal hex wrench. Torque to 2.5 Nm [1.8 lbf ft].
Remove the plug on top of the control to ensure the swashplate feedback pin is properly positioned in the center of the control module when installing control.
5. Install the control module and six cap screws (D250).
Torque sequence
2
3
4
5
6
1
6. Using a 5 mm internal hex wrench, torque the cap screws (D250) to 13.3 Nm [9.8 lbf ft].
Angle sensor on EDC
Removal
1. Clean the exterior of the pump to remove debris.
2. Remove protection cover screws (D767) using a 4 mm internal hex wrench.
3. Remove the protection cover from the control.
4. If protection cover is damaged, discard.
5. Remove sensor screws (D770) using a 4 mm internal hex wrench.
6. Remove and discard the sensor.
Position sensor
D767
D770
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 45
Item Wrench size Torque
D767 4 mm 1.85 N•m [1.36 lbf•ft] D770 4 mm 1.85 N•m [1.36 lbf•ft]
Installation
1. Position sensor on control housing.
2. Using a 4 mm internal hex wrench, fasten sensor to control housing with screws (D770). Torque
screws to 1.85 N•m [1.36 lbf•ft].
3. Postion protection cover on control housing over sensor.
4. Using a 4 mm internal hex wrench, fasten protection cover with screws (D767). Torque screws to 1.85
N•m [1.36 lbf•ft].
W
Warning
Calibration of sensor output in vehicle software is mandidtory after sensor replacement because output signal can vary from one sensor to the next.
EDC with angle sensor
Removal
1. Clean pump externally with clean solvent to remove debris.
2. Remove control screws (D250) using a 5 mm internal hex wrench.
3. Remove the control from the pump.
Dowel pins (D300) must remain in housing.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
46 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
4. Remove and discard the control gasket.
D250
D150
Feedback link
Item Wrench size Torque
D250 5 mm 13.5 N•m [10 lbf•ft]
Installation
1. Install new control gasket (D150).
2. Before positioning the control on the pump housing ensure assembly fixture is positioned over the
linkage spring in EDC center as shown on the right.
3. Position control on pump housing. Ensure that feedback pin on swashplate is positioned properly in
control arm.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 47
4. Pull assembly fixture out before installing control screws.
Solenoid shaft
Feedback pin
Adjusting screw (cam)
Maximum adjustment less than 120°
Control spool
Remove plug (D065) and verify the swashplate feedback pin is properly positioned between control feedback arms.
5. Using a 5 mm internal hex wrench, fasten control to pump with screws (D250). Torque screws to 13.5
N•m [10 lbf•ft] following torque sequence shown.
1
2
3
6
5
4
Torque sequence (6 screw control)
D065
W
Warning
Calibration of sensor output in vehicle software is mandidtory after sensor replacement because output signal can vary from one sensor to the next.
For proper neutral adjustment procedure, refer to
Automotive Control
Removal
1. Drain pump completely before removing control. Disconnect and remove wiring (D640).
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
48 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
2. Fabricate a special tool to remove two plastic plugs (D610). See drawing below for tool dimensions.
Push down on plug and turn 45 degrees counterclockwise. Discard plugs.
Wax seals will be destroyed when the plugs are removed. Do not damage the housing in the plug sealing area.
3. Use a 5 mm internal hex to remove two screws (D674). Remove shield (D672).
4. Use a 5 mm internal hex to remove six screws (D250). Remove control from pump.
5. Remove and discard gasket (D150).
Alignment pins are pressed into control. Do not remove them.
6. If necessary, use a 3 mm internal hex to remove orifices (F00A, F00B) from housing. Tag each orifice
for reinstallation. Each orifice may be a different size.
7. If it is necessary to remove the screens, drill out screen retention ring (D098) and remove and discard
screen (D084). Note screen orientation for reassembly.
W
Warning
Do not allow metal fragments to fall into control housing. This may cause erratic pump operation.
Drill Out Retention Ring
Screen
Retention Ring
P108 022E
Remove Control
D250 5 mm (6X)
D150
F00A
3 mm
F00B
P107 990E
D610 (2X)
Security wax seal (2X)
D640
D084
D098
13.3 Nm [9.8 lbf•ft]
2.5 Nm [1.8 lbf•ft]
D674
D672
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 49
Special Tool
Special
tool
Plug
P108 021E
Ø 1.7 mm (x3)
Ø 9.22 mm
45 deg.
Ø 14 mm
Inspection
Inspect machined surfaces on control and pump housing. Inspect plastic PC board housing and its sealing areas. If any damage is found, replace damaged components.
Controls are available as a complete unit. Do not disassemble the control.
Assembly
1. If previously removed, install new screen (D084) in original orientation. Press in new retention ring
(D098).
Be sure screen will not move axially in bore after retention ring is installed.
W
Warning
Failure to install screen will result in erratic pump operation.
Proper Screen Orientation
P106 618E
D084
D084
Incorrect screen orientation
Correct screen orientation
D094
2. If previously removed, use a 3 mm internal hex to install orifices (F00A, F00B) in original orientation.
Torque to 2.5 N•m [1.8 lbf•ft][.
3. Install new gasket (D150) to bottom of control.
If pump has been rebuilt or a new control is being installed, control software must be recalibrated. Refer to H1-Automotive Control User Manual 70012797 for recalibration instructions.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
50 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
4. Install control on pump. Use a 5 mm internal hex to install six screws (D250). Torque to 13.3 N•m [9.8
lbf•ft]. Follow torque sequence shown on page 43.
Do not damage the plastic housing in the plug sealing area when installing the screws.
5. Connect wiring (D640).
6. Use the special tool to install new plastic plugs with O-rings (D610). Press plugs in and turn 45
degrees clockwise.
If control will continue to be under warranty, install new sealing wax of a different color (original wax is blue). Pumps without sealing wax installed will not be warrantied.
7. Install protection bracket (D672). Install screws (D674). Torque to 5 N•m [3.7 lbf•ft].
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 51
Bearing and Shaft Replacement
The input shaft, seal, and front bearing are serviceable without disassembling the entire pump. Orient the pump on the work surface so the shaft is pointing up.
Removal
1. Using a snap-ring pliers, remove the outer snap-ring (J200).
2. (For 069/078, 115/130, 147/165) Puncture the seal (J250) and use a slide-hammer type puller to
remove the seal. Discard the seal.
C
Caution
Do not damage the housing bore, shaft or bearing when removing the seal.
(For 89/100 and 210/250) Use a small pry device against the raised edge of the seal carrier to remove the seal/carrier assembly. Discard the assembly.
3. Use a press or gear puller to press down on the shaft. Using a snap-ring pliers, remove the inner snap-
ring (J200).
4. Remove the shaft (J100) and bearing (J150) from the pump. It may be necessary to tap the shaft to
dislodge it from the internal pump components. After you remove the shaft, take care not to move or jar the pump. Reassembly can be difficult if the internal components move while the shaft is out.
5. Remove snap-ring (J300). Press bearing (J150) from shaft.
Inspection
Inspect the shaft and bearing for wear, scratching and pits. Rotate the bearing and feel for roughness. Replace damaged components.
Reassemby
1. Press bearing (J150) on shaft. Install snap-ring (J300).
2. Install the shaft/bearing assembly into the pump. Rotate the shaft to align it with the block and
charge pump splines. Press down on the shaft and replace the inner snap-ring (J200).
3. Cover end of the shaft with an installation sleeve to protect the seal during installation. Lubricate the
seal. Tap on the seal replacing tool or an appropriate deep-socket to press in the seal. Remove the protective cover. Refer to Seal Installation Tool illustration below for installation sleeve and seal installation tool part numbers and dimensions.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
52 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
4. Install the remaining snap-ring.
Shaft Assembly
J100
P106038
J150
J300
J250
J200
J200
Protective cover
Seal installation tool
J150
J220
Seal Installation Tool
P106492
55 mm
[2.17 in]
120 mm
[4.72 in]
078/089/100
78 mm
[3.07 in]
82 mm
[3.23 in]
115/130 147/165
7 mm
[0.28 in]
51 mm [2. in]
68.5 mm
[2.70 in]
50°
80°
44.7 mm [1.76 in]
89.4 mm [3.52 in]
7 mm [0.276 in]
78 mm
[3.07 in]
75.6 mm [2.97 in]
210/250
4.4 mm
[0.17 in]
80°
57.5 mm [2.26 in]
89.4 mm [3.52 in]
External Filter Replacement
Removal
1. With the prime mover off, hold the filter (T150) in place, and remove the plug (T015) using a 24 mm
wrench.
2. Remove the filter.
3. Remove and discard the seal (T045) and O-ring (T035).
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 53
Inspection
Inspect the plug and sealing surfaces in the filter bracket. Replace any damaged components.
Reassembly
1. Install new seal (T045) and O-ring (T035) on plug.
2. Apply hydraulic fluid to the O-ring and seal for lubrication. Insert the plug into the bracket.
3. Use a 24 mm wrench to hold the plug in place and install the replacement filter. Hand tighten filter till
it contacts O-ring, then tighten 1/2 turn further.
4. Start the prime mover. Cycle the pump through normal machine operation and check for leaks.
External Filter Replacement
T015 24mm
P106 035E
T150
T035
T045
Filter Bypass Valve and Filter Bypass Switch
Removal
1. Remove three screws (T250) using a 6mm internal hex wrench.
2. Remove the filter adapter (T010) and gasket (T350). Discard the gasket.
3. Use an 8 mm internal hex wrench to remove plugs (T025).
4. Remove and discard O-rings (T040).
5. Remove spring (T030), and poppet (T020).
6. If necessary, use a 3 mm internal hex wrench to remove cap screws (T300) and bypass switch (T200).
It is not necessary to remove switch (T200) unless it is being replaced.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
54 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Inspection
1. Inspect poppet (T020) for bending or damage. Replace if necessary.
2. Inspect spring (T030) for cracks or warpage. Replace if necessary.
3. Inspect sealing surface of filter adapter (T010) for scratches or damage. Resurface or replace scratched
or damaged part.
Reassembly
1. Lubricate and replace O-ring (T040) on plug (T025).
2. Install poppet (T020), spring (T030), and plug (T025). Torque to 18 N•m [13 lbf•ft].
3. If replacing bypass switch, install and torque 3 mm cap screws (T300) to 1.4 N•m [1 lbf•ft].
4. Install adapter assembly (T010) using new gasket (T350) to pump. Install cap screws (T250) using a
6mm internal hex wrench. Torque to 32 N•m [24 lbf•ft].
Filter Adapter Replacement
P106 138E
3 mm
1.5 N•m [1 lbf•ft]
T025 6 mm
T200
T300
T020
T030
T040
16-20 N•m
[12 - 15 lbf•ft]
T025 6 mm
T040
16-20 N•m
[12 - 15 lbf•ft]
T010
T250
T350
6mm 32 N•m [24 lbf•ft]
Charge Pump
If the pump has an auxiliary pump attached, remove the auxiliary pump and coupling before removing the auxiliary pad.
Charge pump removal (removable auxiliary pad/cover)
1. Using a 10 mm internal hex wrench, remove cap screws (K400).
2. Remove charge pump cover or auxiliary pad (K100) and gasket (K150). Discard the gasket. Alignment
pins (G450) may remain in cover or endcap.
3. Remove thrust washer (K500). Note its orientation. Coated side is towards charge pump coupling
(K200).
4. Remove pressure-balance plate (S200) with seal (S300). Note orientation of plate and seal. Discard
seal.
5. Remove charge pump coupling (K200).
6. Remove charge pump gearset (S100) and outer ring (S150).
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 55
7. Remove valve plate (S250) with seal (S300). Note orientation of valve plate and seal. Discard seal
(S300).
Charge Pump Removal/Installation
P106 036E
K100
K150
K500
G450
S150
S300
S250
S100
S300
S200
K200
K100
K400 10 mm 92 Nm [68 ft•lb]
K400 10 mm 92 Nm [68 ft•lb]
Charge Pump Removal (integrated auxiliary pad)
1. Remove auxilliary pump and O-ring (K250). Discard O-ring.
2. Remove charge pump cover screws (K450) and charge pump cover (K550).
3. Remove thrust washer (K500). Note its orientation. Coated side is towards charge pump coupling
(K200).
4. Remove pressure-balance plate (S200) with seal (S300). Note orientation of valve plate and seal.
Discard seal (S300).
5. Remove charge pump coupling K200).
6. Remove charge pump gearset (S100) and outer ring (S150).
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
56 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
7. Remove valve plate (S250) with seal (S300). Note orientation of valve plate and seal. Discard seal
(S300).
Charge Pump Removal/Installation (integrated auxiliary pad)
P106 353E
S150
S300
S250
S100
S300
S200
K200
K500
K550
K250
K450 6 mm 10 Nm [7 ft•lb]
Inspection
Inspect the components for wear, scratches or pitting. Carefully inspect the valve and pressure-balance plates. Scratches on these components will cause a loss of charge pressure. If any component shows signs of wear, scratching, or pitting, replace it.
Reassemby
1. Install new seals (S300) in the valve (S250) and pressure-balance (S200) plates.
2. Install valve plate (S250) in the same orientation as removed.
3. Lubricate and install charge pump gearset (S100) and outer ring (S150).
4. Install charge pump coupling (K200).
5. Install pressure-balance plate (S200) in the same orientation as removed.
6. Install the thrust washer (K500). Coated side goes towards charge pump coupling (K200).
7. Install a new cover gasket (K150). If removed,install guide pins (K450).
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 57
8. Install the auxiliary pad or charge pump cover and cap screws. Using a 10mm internal hex wrench,
torque the cap screws (K400) to 92 N•m [68 ft•lb], or using a 6mm internal hex wrench (K450), torque to 10 N•m [7 lbf•ft]. Torque in sequence below.
Ensure proper torque on aux pad screws (K400). If necessary, replace screws.
If charge pump replacement is necessary, replace complete charge pump kit.
Cover (K100) Torque Sequence
P106 196E
1
2
3
4
5
6
7
8
Cover (K550) Torque Sequence
1
2
3
5
4
6
P106 659E
High Pressure Relief Valves (HPRV)
Removal
Using a hex wrench wrench shown in the table below, remove the HPRVs (L150). Remove and discard the O-rings (L060) and backup rings (L068).
Inspection
Inspect the sealing surfaces in the pump for nicks or scratches. Check the valves for damage. Replace any damaged components.
Reassembly
1. Lubricate and install new backup rings (L068) and O-rings (L060).
2. Install HPRVs. Torque to the value in the table below.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
58 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
3. Operate the vehicle/machine through full range of controls to ensure proper operation. Check for
leaks.
HPRVs
L150
P106 039E
L068
L060
see table
HPRV Wrench Size and Torque Values
Displacement Wrench size and torque
069/078/089/100 22 mm - 70 N•m [52 lbf-ft] 115/130/147/165/210/250 30 mm - 110 N•m [81 lbf-ft]
Charge Pressure Relief Valve
Replace the charge pressure relief valve (V010) as a complete unit. Do not attempt to repair the internal components of the valve. Torque to 52 N•m [38 lbf•ft]
See Charge Pressure Relief Valve djustment, page 31, for adjustment instructions.
Removal
Using a 22 mm wrench, remove the charge pressure relief valve (V010). Discard seal (V024).
Inspection
Inspect the sealing surfaces of the pump for nicks or scratches.
Reassembly
1. Lubricate and install new seal (V024).
2. Install the charge pressure relief valve. Torque to 52 N•m [38 lbf•ft].
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 59
3. Operate vehicle/machine through full range of controls to ensure proper operation.
Charge Pressure Relief Valve
P106 040E
V010
V024
22 mm 52 N•m [38 lbf•ft]
Pressure Limiter Valve Replacement
Replace the pressure limiter valve as a complete unit. Do not attempt to repair individual components. See Pressure Limiter Adjustment, page 32, for adjustment instructions.
Removal
Using a 22 mm wrench, remove the pressure limiter valve (L100). Discard O-ring.
Inspection
Inspect the sealing surfaces of the pump for nicks or scratches.
Reassemby
1. Install new O-ring. Lubricate O-ring with petroleum jelly.
2. Replace pressure limiter valve. Torque to the value in the table below.
3. Operate pump at full range of controls to ensure proper machine operation.
Pressure limiter is available as complete unit only. O-ring is available separately.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
60 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Pressure Limiter
E101336
L300
L022
L400
O
Wrench Size and Torque Values
Displacement Wrench size and torque
069/078/089/100/115/130/147/165 22 mm - 70 N•m [52 lbf-ft] 210/250 24 mm - 70 N•m [52 lbf-ft]
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 61
Fastener Size and Torques
069/078/089/100/115/130/147/165/210/250
Item Fastener Wrench size Torque
D015 Neutral adjust screw 4 mm internal hex NA D050 Coil mounting bolt 4 mm internal hex 8 N•m [6 lbf•ft] D060 Neutral adjust locking nut 13 mm 10 N•m [7 lbf•ft] D200 Swash plate feedback pin (not shown) 13 mm deep well socket 25 N•m [18 lbf•ft] D250 Electric control mounting bolt 5 mm internal hex 13.3 N•m [9.8 lbf•ft] E350 Servo can locking bolt 10 mm 14 N•m [10 lbf•ft] T015 Filter mounting bolt 24 mm 21 N•m [15 lbf•ft] T025 Filter adapter gage plug 6 mm internal hex 18 N•m [13 lbf•ft] V010 Charge pressure cartridge 22 mm 52 N•m [38 lbf•ft] V020 Charge pressure adjusting screw 4 mm internal hex NA V022 Charge pressure locking nut 13 mm 12 N•m [9 lbf•ft] V022
Charge pressure locking nut (210/250) 19 mm 12 N•m [9 lbf•ft]
069/078/089/100
Item Fastener Wrench size Torque
K400 Rear cover/Aux pad mounting bolt 10 mm internal hex 100 N•m [74 lbf•ft] K450 Charge Pump Cover Screw 5 mm internal hex 25 N•m [18.5 lbf•ft] L010 Pressure limiter adjust screw 8 mm NA L012 Pressure limiter cartridge 17 mm 40 N•m [22 lbf•ft] L024 Pressure limiter locking nut 14 mm 20 N•m [15 lbf•ft] L150 High pressure relief valve 22 mm 70 N•m [52 lbf•ft]
115/130/147/165/210/250
Item Fastener Wrench size Torque
K400 Rear cover/Aux pad mounting bolt 10 mm internal hex 100 N•m [74 lbf•ft] K450 Charge Pump Cover Screw 5 mm internal hex 10 N•m [7 lbf•ft] L010 Pressure limiter adjust screw 5 mm internal hex NA L012 Pressure limiter cartridge 22 mm 70 N•m [52 lbf•ft] L012 Pressure limiter cartridge (210/250) 24 mm 70 N•m [52 lbf•ft] L024 Pressure limiter locking nut 17 mm 20 N•m [15 lbf•ft] L028 Pressure limiter plug (special) 19 mm 68 N•m [50 lbf•ft] L150 High pressure relief valve 30 mm 110 N•m [81 lbf•ft]
Plug Size and Torques
069/078/089/100/115/130/147/165/210/250
Item O-ring plug Wrench size Torque
B015 7/16 - 20 3/16 mm internal hex 12 N•m [9 lbf•ft] B020 (069/078) 7/8 - 14 3/8 internal hex 70 N•m [52 lbf•ft] B020 (147/165) 1-1/16 - 12 9/16 internal hex 70 N•m [52 lbf•ft]
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Torque Chart
62 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
069/078/089/100/115/130/147/165/210/250 (continued)
Item O-ring plug Wrench size Torque
B020 (210/250) 1-5/16 - 12 5/8 internal hex 150 N•m [110 lbf•ft] B035 (069/078) 1 1/16 - 12 9/16 internal hex 70 N•m [52 lbf•ft] B035 (147/165) 1 5/16 - 12 5/8 internal hex 150 N•m [110 lbf•ft] D065 7/16 - 20 3/16 internal hex 12 N•m [9 lbf•ft] G250 9/16 - 18 1/4 internal hex 40 N•m [29.5 lbf•ft] G300 9/16 - 18 3/16 internal hex 40 N•m [29.5 lbf•ft] G302 5/16 - 24 UNF 1/8 internal hex 5 N•m [4 lbf•ft]
Fasteners and Plugs
P106 066E
T015
Filter mounting bolt
K400
Rear cover / auxiliary pad mounting bolt
V020
Charge pressure adjusting screw
V022
Charge pressure locking nut
V010
Charge pressure cartridge
L150
High pressure relief valve
L150
High pressure relief valve
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Torque Chart
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 63
P106 497E
D250
Electric control mounting bolt
E350
Servo can locking bolt
L010 Pressure limiter adjusting screw
L024 Pressure limiter locking nut
L028 Pressure limiter plug (special)
L012 Pressure limiter cartridge
D015 Neutral adjusting screw
D060 Neutral adjust locking nut
D050 Coil mounting bolt
B015 O-ring plug, 7/16 - 20
G302 O-ring plug, 5/16 - 24 UNF
G300 O-ring plug, 9/16 - 18
B035 O-ring plug, see table
G250 O-ring plug, 9/16 - 18
G302
O-ring plug 5/16 - 24 UNF
D065 O-ring plug, 7/16 - 20
B020 O-ring plug
1-1/16 - 12
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Torque Chart
64 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 65
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
66 | © Danfoss | May 2018 520L0848 | AX00000087en-US0308
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308 | 67
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles.
We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster.
Danfoss – Your Strongest Partner in Mobile Hydraulics.
Go to www.powersolutions.danfoss.com for further product information.
Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components.
Please contact the Danfoss Power Solution representative nearest you.
Local address:
Danfoss Power Solutions GmbH & Co. OHG
Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0
Danfoss Power Solutions ApS
Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222
Danfoss Power Solutions (US) Company
2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000
Danfoss Power Solutions Trading (Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
©
Danfoss | May 2018 520L0848 | AX00000087en-US0308
Products we offer:
Bent Axis Motors
Closed Circuit Axial Piston Pumps and Motors
Displays
Electrohydraulic Power Steering
Electrohydraulics
Hydraulic Power Steering
Integrated Systems
Joysticks and Control Handles
Microcontrollers and Software
Open Circuit Axial Piston Pumps
Orbital Motors
PLUS+1® GUIDE
Proportional Valves
Sensors
Steering
Transit Mixer Drives
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com
Loading...