Danfoss GX Snow Melting System Data sheet

Data Sheet

GX Snow Melting System

 

Digital Sensors

General

Information

Sensor

Tube

 

Sensor

Ground (#088L3051)

Roof (#088L3052)

The Danfoss digital sensors are used with the GX 850 Automatic Control Panel and the GX 850M Controller - the most optimal solutions for keeping an area free of ice and snow. The controllers act on information received from the sensor(s),which register both temperature and moisture, and then calculates the information ensuring that the heat will only be turned on when snow and/or ice is present. The result is optimal performance with maximum energy savings and minimum operating costs.

Precise measurement of temperature and moisture

Rugged construction

Built-in heating

Self-adjusting moisture sensitivity

Protected against galvanic corrosion

Technical Data -

Ground Sensor

Supply Voltage:

24 Vdc (supplied by GX 850 ACP)

Operating Temperature:

-22°F to 158°F (-30°C to +70°C)

Sensor Lead:

50’ (15 m) of 16AWG 4-wire jacketed cable

Ground Sensor Dimensions: Sensor: Diameter 3.5”, Height 3” (89m x 76mm) Tube: Diameter 3.5” Height 3.75 (89mm x 95mm)

Technical Data -

Roof Sensor

Supply Voltage:

24 Vdc (supplied by GX 850 ACP)

Operating Temperature:

-58°F to 158°F (-50°C to +70°C)

Sensor Lead:

50’ (15 m) of 16AWG 4-wire jacketed cable

Roof Sensor Dimensions

1” x 8.5” x 0.5” (25mm x 216mm x 13mm)

(HxWxD):

 

© Copyright 2018 Danfoss

12/18

TEL: 1-888-326-3677, FAX: 416-352-5981 1

Danfoss GX Snow Melting System Data sheet

Typical

Application

Note: Danfoss recommends a minimum of two ground sensors per heating zone.

Ordering

Information

Part No.

Description

088L3412

GX 850 Automatic Control Panel (ACP)

088L3415

GX 850M Snow Melt Controller

088L3051

Ground Sensors (two per package)

088L3052

Roof Sensor (includes 50 ft. lead wire)

Warranty

Danfoss offers a two year limited warranty covering defects in workmanship and materials.

Technical

Services

For technical questions, please contact Danfoss Heating Division North America at 1-888-326-3677. More information on Danfoss Electric Heating products is available at www.LX.Danfoss.com.

Danfoss

can accept no

responsibility

for possible errors in catalogs, brochures, other printed materials, and

website information.

Danfoss reserves the right to alter its

 

products

without notice.

This also

applies to products already on order provided that such alteration can

be made without

subsequent changes being necessary in

specifications already agreed upon.All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of DanfossA/S. All rights reserved.

Danfoss

Toll Free: 1-888-326-3677 Fax: 416-352-5981 www.LX.Danfoss.com

DanfossGX

BRINGING WARMTH TO LIFE

© Copyright 2018 Danfoss

12/18

TEL: 1-888-326-3677, FAX: 416-352-5981 2