Danfoss GX Cable Data sheet

Data Sheet GX Cable
Electric Snow Melting
General Information
Technical Data
Installing a Danfoss GX Snow Melting System provides a permanent solution to the problems caused by cold weather. Improve safety by providing instantaneous relief from snow and ice and increase your bottom line by reducing the costs associated with applying chemicals, owning snow clearing machinery or hiring outside services.
• Twin conductor cable
• Single point connection
• Easy and exible installation
• Durable construction
• Silent, ecient and safe
• For use in concrete, asphalt and under pavers
• Zero EMF’s (Electromagnetic elds)
• Genuine twenty year non-prorated warranty
Cable Construction: Twin conductor Rated Voltage: 208V, 240V, 277V, 480V, 600V Output (Cables): 12W/ft. (40W/m) Cold Lead: 20 feet (6.0 m) Bending Radius: Minimum 1.5 inches (38 mm) Cable Diameter: 1/4 inches (6.5 mm) Conductor Insulation: TeonTM FEP Filler Sheath: PEX Outer Insulation: PVC Max. Temperature: 220°F (105°C) Min. Installation Temp: 40°F (5°C)
See power lead label for NEC connection color code.
Ordering Information GX Cables - 208V
Power leads are 20 feet in length.
Standard cable spacing is 3 inches.
3” centers provide 50 w/sq ft. 4” centers provide 35 w/sq. ft.
© Copyright 2016 Danfoss VDAPN222 .07/16 TEL: 866-676-8062, FAX: 416-352-5981 1
Part No.
088L3123 85 20 30 1,020 4.9 42.4
088L3124 105 25 35 1,265 6.1 34.1
088L3125 125 30 45 1,500 7.2 28.9
088L3126 145 35 50 1,745 8.4 24.8
088L3127 160 40 55 1,915 9.2 22.6
088L3128 180 45 60 2,165 10.4 20.0
088L3129 210 50 70 2,515 12.1 17.2
088L3130 245 60 85 2,930 14.1 14.8
088L3132 320 75 110 3,850 18.5 11.2
088L3133 355 85 120 4,265 20.5 10.1
088L3134 410 100 140 4,930 23.7 8.8
088L3135 460 110 160 5,510 26.5 7.8
Length
(feet)
Approximate Heat Coverage (sq.ft.)
3” spacing 4” spacing
Watts
(12W/ft.)
Amps Ohms
Ordering Information GX Cables - 240V
Power leads are 20 feet in length.
Standard cable spacing is 3 inches.
3” centers provide 50W/sq.ft. 4” centers provide 35W/sq.ft.
Watt output of the 240V cable is reduced by 25% when operated at 208V (approx. 9W/ft.)
Part No.
Length
(feet)
Approximate Heat Coverage (sq.ft.)
3” spacing 4” spacing
Watts
(12W/ft.)
Amps Ohms
088L3100 40 10 15 480 2.0 120.0
088L3101 60 15 20 720 3.0 80.0
088L3102 80 20 25 960 4.0 60.0
088L3103 100 25 35 1,200 5.0 48.0
088L3104 120 30 40 1,440 6.0 40.0
088L3105 145 35 50 1,750 7.3 32.9
088L3106 165 40 55 1,990 8.3 28.9
088L3107 185 45 65 2,230 9.3 25.8
088L3108 205 50 70 2,470 10.3 23.3
088L3109 245 60 85 2,950 12.3 19.5
088L3110 285 70 100 3,430 14.3 16.8
088L3111 325 80 110 3,910 16.3 14.7
088L3112 370 90 125 4,440 18.5 13.0
088L3113 410 105 140 4,920 20.5 11.7
088L3114 475 120 165 5,710 23.8 10.1
088L3115 535 135 185 6,430 26.8 9.0
Ordering Information GX Cables - 277V
Power leads are 20 feet in length.
Standard cable spacing is 3 inches.
3” centers provide 50W/sq.ft. 4” centers provide 35W/sq.ft.
Watt output of the 277V cable is reduced by 25% when operated at 240V (approx. 9W/ft.)
Ordering Information GX Cables - 480V
Power leads are 20 feet in length.
Standard cable spacing is 3 inches.
3” centers provide 50W/sq.ft. 4” centers provide 35W/sq.ft.
Part No.
Length
(feet)
Approximate Heat Coverage (sq.ft.)
3” spacing 4” spacing
Watts
(12W/ft.)
Amps Ohms
088L3065 170 40 60 2,020 7.3 38.5
088L3066 190 45 65 2,325 8.4 33.0
088L3067 215 50 75 2,600 9.4 29.5
088L3068 240 55 80 2,855 10.3 26.9
088L3069 285 65 95 3,435 12.4 22.3
088L3070 330 80 115 4,015 14.5 19.1
088L3071 375 90 125 4,600 16.6 16.7
088L3072 425 100 145 5,150 18.6 14.9
088L3073 475 115 160 5,760 20.8 13.3
088L3074 545 130 185 6,590 23.8 11.7
Part No.
Length
(feet)
Approximate Heat Coverage (sq.ft.)
3” spacing 4” spacing
Watts
(12W/ft.)
Amps Ohms
088L3640 80 20 25 1010 2.1 232.0
088L3644 200 50 70 2,450 5.1 93.5
088L3646 330 85 110 4,030 8.4 57.1
088L3648 490 125 160 6,000 12.5 38.5
088L3650 735 185 240 8,930 18.6 25.7
088L3652 820 205 270 10,030 20.9 23.0
088L3654 940 235 310 11,475 23.9 20.1
© Copyright 2016 Danfoss VDAPN222.07/16 TEL: 866-676-8062, FAX: 416-352-5981 2
Loading...
+ 2 hidden pages