Danfoss GX Cable Data sheet

Danfoss GX Cable Data sheet

Data Sheet

GX Cable

 

Electric Snow Melting

General

Information

Installing a Danfoss GX Snow Melting System provides a permanent solution to the problems caused by cold weather. Improve safety by providing instantaneous relief from snow and ice and increase your bottom line by reducing the costs associated with applying chemicals, owning snow clearing machinery or hiring outside services.

Twin conductor cable

Single point connection

Easy and flexible installation

Durable construction

Silent, efficient and safe

For use in concrete, asphalt and under pavers

Zero EMF’s (Electromagnetic fields)

Genuine twenty year non-prorated warranty

Technical Data

Cable Construction:

Twin conductor

Rated Voltage:

208V, 240V, 277V, 480V, 600V

Output (Cables):

12W/ft. (40W/m)

Cold Lead:

20 feet (6.0 m)

Bending Radius:

Minimum 1.5 inches (38 mm)

Cable Diameter:

1/4 inches (6.5 mm)

Conductor Insulation:

TeflonTM FEP

Filler Sheath:

PEX

Outer Insulation:

PVC

Max. Temperature:

220°F (105°C)

Min. Installation Temp:

40°F (5°C)

See power lead label for NEC connection color code.

Ordering Information GX Cables - 208V

Power leads are 20 feet in length. Standard cable spacing is 3 inches.

3” centers provide 50 w/sq ft. 4” centers provide 35 w/sq. ft.

Part No.

Length

Approximate Heat Coverage (sq.ft.)

Watts

Amps

Ohms

(feet)

3” spacing

4” spacing

(12W/ft.)

 

 

 

 

 

 

 

 

 

 

088L3123

85

20

30

1,020

4.9

42.4

088L3124

105

25

35

1,265

6.1

34.1

088L3125

125

30

45

1,500

7.2

28.9

088L3126

145

35

50

1,745

8.4

24.8

088L3127

160

40

55

1,915

9.2

22.6

088L3128

180

45

60

2,165

10.4

20.0

088L3129

210

50

70

2,515

12.1

17.2

088L3130

245

60

85

2,930

14.1

14.8

088L3132

320

75

110

3,850

18.5

11.2

088L3133

355

85

120

4,265

20.5

10.1

088L3134

410

100

140

4,930

23.7

8.8

088L3135

460

110

160

5,510

26.5

7.8

© Copyright 2016 Danfoss

VDAPN222 .07/16

TEL: 866-676-8062, FAX: 416-352-5981 1

Ordering Information

GX Cables - 240V

Power leads are 20 feet in length.

Standard cable spacing is 3 inches.

3” centers provide 50W/sq.ft. 4” centers provide 35W/sq.ft.

Watt output of the 240V cable is reduced by 25% when operated at 208V (approx. 9W/ft.)

Ordering Information

GX Cables - 277V

Power leads are 20 feet in length.

Standard cable spacing is 3 inches.

3” centers provide 50W/sq.ft. 4” centers provide 35W/sq.ft.

Watt output of the 277V cable is reduced by 25% when operated at 240V (approx. 9W/ft.)

Part No.

Length

Approximate Heat Coverage (sq.ft.)

Watts

Amps

Ohms

(feet)

3” spacing

4” spacing

(12W/ft.)

 

 

 

 

 

 

 

 

 

 

088L3100

40

10

15

480

2.0

120.0

088L3101

60

15

20

720

3.0

80.0

 

 

 

 

 

 

 

088L3102

80

20

25

960

4.0

60.0

 

 

 

 

 

 

 

088L3103

100

25

35

1,200

5.0

48.0

088L3104

120

30

40

1,440

6.0

40.0

088L3105

145

35

50

1,750

7.3

32.9

088L3106

165

40

55

1,990

8.3

28.9

088L3107

185

45

65

2,230

9.3

25.8

088L3108

205

50

70

2,470

10.3

23.3

088L3109

245

60

85

2,950

12.3

19.5

088L3110

285

70

100

3,430

14.3

16.8

088L3111

325

80

110

3,910

16.3

14.7

088L3112

370

90

125

4,440

18.5

13.0

088L3113

410

105

140

4,920

20.5

11.7

088L3114

475

120

165

5,710

23.8

10.1

088L3115

535

135

185

6,430

26.8

9.0

 

 

 

 

 

 

Part No.

Length

Approximate Heat Coverage (sq.ft.)

Watts

Amps

Ohms

(feet)

3” spacing

4” spacing

(12W/ft.)

 

 

 

 

 

 

 

 

 

 

088L3065

170

40

60

2,020

7.3

38.5

088L3066

190

45

65

2,325

8.4

33.0

 

 

 

 

 

 

 

088L3067

215

50

75

2,600

9.4

29.5

 

 

 

 

 

 

 

088L3068

240

55

80

2,855

10.3

26.9

088L3069

285

65

95

3,435

12.4

22.3

088L3070

330

80

115

4,015

14.5

19.1

088L3071

375

90

125

4,600

16.6

16.7

088L3072

425

100

145

5,150

18.6

14.9

088L3073

475

115

160

5,760

20.8

13.3

088L3074

545

130

185

6,590

23.8

11.7

Ordering Information

GX Cables - 480V

Power leads are 20 feet in length.

Standard cable spacing is 3 inches.

3” centers provide 50W/sq.ft. 4” centers provide 35W/sq.ft.

Part No.

Length

Approximate Heat Coverage (sq.ft.)

Watts

Amps

Ohms

(feet)

3” spacing

4” spacing

(12W/ft.)

 

 

 

 

 

 

 

 

 

 

088L3640

80

20

25

1010

2.1

232.0

088L3644

200

50

70

2,450

5.1

93.5

 

 

 

 

 

 

 

088L3646

330

85

110

4,030

8.4

57.1

 

 

 

 

 

 

 

088L3648

490

125

160

6,000

12.5

38.5

088L3650

735

185

240

8,930

18.6

25.7

088L3652

820

205

270

10,030

20.9

23.0

088L3654

940

235

310

11,475

23.9

20.1