GTU Pressure Equalizer
Substitute for safety valve to the Termix water heaters
Installation
Note:
The GTU Pressure Equalizer is VAapproved(Danishnorm)tobemounted inGeminaTermixdistrictheatingunits.
The GTU Pressure Equalizer absorbs the expansion on the secondary side of the Termixwaterheatersandcanbeusedas asubstitutetothesafetyvalve.
Furthermore the pressure equalizer absorbs a possible increase in pressure, soadischargeoutletisomitted.
The GTU Pressure Equalizer can be applied to Termix One, VMTD-F, VMTD, VMTD-mix andVVX. See table below for detailedspecifications.
The GTU Pressure Equalizer may not be applied to theTermix One type 3 and in systemswithhotwatercirculation.
The pressure equalizer is delivered completewithacheckvalve.
Maxfluidtemperature: 95°C
Maxpressure: 10bar
The GTU Pressure Equalizer can be applied to:
Termix One type 1 |
Termix VMTD-1 |
Termix VMTD-1-mix |
Termix VVX 1-x |
|
|
|
|
Termix One type 2 |
Termix VMTD-2 |
Termix VMTD-2-mix |
Termix VVX 2-x |
|
|
|
|
|
Termix VMTD-3 |
Termix VMTD-3 |
Termix VVX 3-x |
|
|
|
|
Note: cannot be used for Termix One type 3 and systems with hot water circulation