GS26CLX
LBP Compressor
R404A/R507
220-240V 60Hz
General
Code number 107B0505
Approvals UL984
Compressors on pallet 48
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -45 to -10
Voltage range V 187 - 254
Max. condensing temperature continuous (short) °C 50 (60)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C – – – F2– –
38°C – – – F
43°C – – – F
Remarks on application:
Motor
Motor type CSR
LRA (rated after 4 sec. UL984), HST | LST A 45.4 –
Cut in Current, HST | LST A 45.4 –
Resistance, main | start winding (25°C) Ω 1.4 5.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 2000
Free gas volume in compressor cm
Weight without electrical equipment kg 22.2
Dimensions
Height mm A 279
Suction connector location/I.D. mm | angle C 12.9 | 90°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.5 | 90°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 8.2 | 19°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm
Remarks:
LBP MBP HBP LBP MBP HBP
– –
2
– –
2
3
3
3
B 267
B1 254
B2 254
12.9 ±0.05, 8.2 ±0.05, 6.5 ±0.10
26.30
900 (polyolester)
3540
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.402.X2.02 / 520N0305 1/2

EN 12900 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 383 586 830 1120 1464 1590 1865 2330 2864
Power cons. in W 533 662 789 917 1048 1094 1190 1344 1516
Current cons. in A 3.44 3.65 3.91 4.23 4.60 4.74 5.04 5.53 6.07
COP in W/W 0.72 0.88 1.05 1.22 1.40 1.45 1.57 1.73 1.89
ARI 540-99 (LBP1) 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 228 395 592 826 1102 1203 1423 1798 2229
Power cons. in W 491 646 795 942 1090 1141 1247 1413 1595
Current cons. in A 3.34 3.60 3.92 4.29 4.73 4.88 5.21 5.76 6.35
COP in W/W 0.46 0.61 0.74 0.88 1.01 1.05 1.14 1.27 1.40
ARI 540-99 (LBP2) 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 357 548 779 1054 1378 1499 1759 2200 2707
Power cons. in W 531 662 790 919 1052 1098 1193 1348 1522
Current cons. in A 1.82 2.26 2.72 3.18 3.66 3.83 4.16 4.67 5.19
COP in W/W 0.67 0.83 0.99 1.15 1.31 1.36 1.47 1.63 1.78
Accessories for
Starting device
GS26CLX
(60Hz)
Figure Code
number
Test conditions EN 12900
ARI 540-99
(LBP1)
ARI 540-99
(LBP2)
Condensing temperature 40°C 48.9°C 40.6°C
600 mm cable length 117-7073 Ambient temperature 32°C 35°C 35°C
a3
Suction gas temperature 20°C 4.4°C 4.4°C
Cover b 107B9106 *
Clamp b1 107B9104 *
Gasket b2 107B9100 *
Starting relay a2
Start. capacitor c Bolt joint for one comp. 107B9150
Run capacitor e Bolt joint in quantities –
)
*
Remarks: Cover, clamp, gasket parts of compressor Snap-on in quantities –
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Components
of starting
device
)
Liquid temperature no subcooling no subcooling no subcooling
)
)
Mounting accessories Code number
2/2 Manufactured by Secop for Danfoss - DEHC.ED.402.X2.02 / 520N0305 Dec 2011