Danfoss FR8.5G Data sheet

FR8.5G Universal Compressor R134a 220-240V 50/60Hz
General
Code number 103G6780
Approvals EN 60335-2-34, UL984, CCC
Application
Application LBP/HBP LBP
Frequency Hz 50 60
Evaporating temperature °C -30 to 10 -30 to -10
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S F2F2S
38°C S F
43°C F
Remarks on application: HBP at 198 - 254V 50Hz only.
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 8.2 8.1
Cut in Current, HST | LST A 8.2 12.8
Resistance, main | start winding (25°C) 8.9 12.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 900
Free gas volume in compressor cm
Weight without electrical equipment kg 10.6
Dimensions
Height mm A 196
Suction connector location/I.D. mm | angle C 8.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 30°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 25°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
1F2F2F1
3
3
3
450 (polyolester)
B 191
B1
B2
S
7.95
1350
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
August 2012 Manufactured by Secop for Danfoss - DEHC.ED.400.F9.02 / 520N1383 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 84.9 123 138 171 228 298 351 381 478 592 647 722
Power cons. in W 127 151 159 176 203 231 251 261 291 321 335 352
Current cons. in A 1.16 1.22 1.25 1.30 1.38 1.47 1.53 1.56 1.67 1.78 1.83 1.90
COP in W/W 0.67 0.82 0.87 0.97 1.12 1.29 1.40 1.46 1.65 1.84 1.93 2.05
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 92.3 138 156 195 263 345
Power cons. in W 134 164 174 197 233 273
Current cons. in A 1.02 1.12 1.16 1.24 1.37 1.53
COP in W/W 0.69 0.85 0.90 0.99 1.13 1.26
ASHRAE LBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 105 152 171 211 282 368 434 471 592 734 803 898
Power cons. in W 127 151 159 176 203 231 251 261 291 321 335 352
Current cons. in A 1.16 1.22 1.25 1.30 1.38 1.47 1.53 1.56 1.67 1.78 1.83 1.90
COP in W/W 0.83 1.01 1.07 1.19 1.39 1.59 1.73 1.81 2.04 2.29 2.40 2.55
ASHRAE LBP 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 114 171 193 241 325 426
Power cons. in W 134 164 174 197 233 273
Current cons. in A 1.02 1.12 1.16 1.24 1.37 1.53
COP in W/W 0.85 1.04 1.11 1.22 1.39 1.56
Accessories for FR8.5G Figure Code number Test conditions
EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 55°C
Starting relay 6.3 mm spade connectors a2 117U6015 Suction gas temperature 32°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature 55°C 32°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 1 6 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.F9.02 / 520N1383 August 2012
Loading...