General

Code number

 

 

 

 

 

103G6692

 

Approvals

 

 

EN 60335-2-34, UL984, CCC

Compressors on pallet

 

 

 

 

 

80

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

HBP

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

Evaporating temperature

 

°C

-15 to 15

 

-15 to 15

Voltage range

 

V

198 - 254

 

198 - 254

Max. condensing temperature continuous (short)

°C

 

60 (70)

 

 

60 (70)

Max. winding temperature continuous (short)

°C

125 (135)

 

125 (135)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

 

MBP

HBP

32°C

 

 

 

O

 

 

O

38°C

 

 

 

O

 

 

O

43°C

 

 

 

O

 

 

O

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

 

CSIR

 

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

9.1

 

 

 

 

 

Cut in Current, HST | LST

 

A

 

9.1

 

 

 

 

 

Resistance, main | start winding (25°C)

 

8.8

 

 

 

12.0

 

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cm3

 

 

 

6.93

 

 

 

Oil quantity (type)

 

cm3

 

 

450 (polyolester)

 

Maximum refrigerant charge

 

g

 

 

 

900

 

 

 

Free gas volume in compressor

 

cm3

 

 

 

1350

 

 

 

Weight without electrical equipment

kg

 

 

 

10.6

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

mm

A

 

 

196

 

 

 

 

 

 

B

 

 

191

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

 

B2

 

 

 

 

 

 

Suction connector

location/I.D. mm | angle

C

 

 

8.2 | 30°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Process connector

location/I.D. mm | angle

D

 

 

6.2 | 30°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location/I.D. mm | angle

E

 

 

8.2 | 25°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Oil cooler connector

location/I.D. mm | angle

F

 

 

6.2 | 25°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Connector tolerance

I.D. mm

 

 

 

±0.09

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

= Static cooling normally sufficient

O

= Oil cooling

F1

= Fan cooling 1.5 m/s

 

 

 

 

(compressor compartment temperature

 

 

 

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

Dec 2011