FR7GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
General
Code number 103G6692
Approvals EN 60335-2-34, UL984, CCC
Compressors on pallet 80
Application
Application HBP
Frequency Hz 50 60
Evaporating temperature °C -15 to 15 -15 to 15
Voltage range V 198 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C – – O – – O
38°C – – O – – O
43°C – – O – – O
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 9.1 –
Cut in Current, HST | LST A 9.1 –
Resistance, main | start winding (25°C) Ω 8.8 12.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 900
Free gas volume in compressor cm
Weight without electrical equipment kg 10.6
Dimensions
Height mm A 196
Suction connector location/I.D. mm | angle C 8.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 30°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 8.2 | 25°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F 6.2 | 25°
material | comment Cu-plated steel | Al cap
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 191
B1 –
B2 –
6.93
450 (polyolester)
1350
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.L7.02 / 520N1198 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 199 255 301 327 417 525 580 655 807
Power cons. in W 165 192 209 217 239 258 266 274 28
Current cons. in A 1.38 1.47 1.53 1.55 1.63 1.70 1.72 1.76 1.81
COP in W/W 1.21 1.33 1.44 1.51 1.74 2.04 2.18 2.39 2.80
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 225 294 348 379 482 607 668 753 924
Power cons. in W 184 217 239 251 284 317 331 350 383
Current cons. in A 1.31 1.41 1.49 1.53 1.65 1.79 1.86 1.94 2.10
COP in W/W 1.22 1.35 1.45 1.51 1.70 1.91 2.02 2.15 2.42
ASHRAE 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 246 316 372 405 516 652 720 814 1005
Power cons. in W 165 192 209 217 239 258 266 274 288
Current cons. in A 1.38 1.47 1.53 1.55 1.63 1.70 1.72 1.76 1.81
COP in W/W 1.49 1.64 1.78 1.86 2.16 2.52 2.71 2.97 3.49
ASHRAE 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 278 363
Power cons. in W 184 217
Current cons. in A 1.31 1.41
COP in W/W 1.51 1.67
430 469 598 753 830 936 1151
239 251 284 317 331 350 383
1.49 1.53 1.65 1.79 1.86 1.94 2.10
1.80 1.87 2.11 2.37 2.50 2.68 3.01
Accessories for FR7GH Figure Code number Test conditions
EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors – Ambient temperature 32°C 32°C
a1
– Condensing temperature 55°C 55°C
Starting relay 6.3 mm spade connectors a2 117U6016 Suction gas temperature 32°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature 55°C 32°C
Cover b 103N2011
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 1 6 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.L7.02 / 520N1198 Dec 2011