FR10G
Universal Compressor
R134a
220-240V 50/60Hz
General
Code number 103G6890
Approvals EN 60335-2-34, CCC
Compressors on pallet 80
Application
Application LBP/HBP LBP
Frequency Hz 50 60
Evaporating temperature °C -30 to 10 -30 to -10
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S F2F2S – –
38°C S F
43°C O F
Remarks on application: HBP at 198 - 254V 50Hz only.
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 10.0 10.3
Cut in Current, HST | LST A 10.0 15.0
Resistance, main | start winding (25°C) Ω 7.3 12.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 900
Free gas volume in compressor cm
Weight without electrical equipment kg 10.6
Dimensions
Height mm A 196
Suction connector location/I.D. mm | angle C 8.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 30°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 25°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F 6.2 | 25°
material | comment Cu-plated steel | Al cap
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
2F2
3
3
3
450 (polyolester)
B 191
B1 –
B2 –
S – –
O – –
9.05
1350
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
August 2012 Manufactured by Secop for Danfoss - DEHC.ED.400.P2.02 / 520N1380 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 91.9 136 152 188 250 324 380 412 516 638 697 779
Power cons. in W 155 179 188 205 234 265 286 296 329 362 376 394
Current cons. in A 1.51 1.58 1.61 1.66 1.75 1.84 1.91 1.94 2.05 2.16 2.21 2.28
COP in W/W 0.59 0.76 0.81 0.91 1.07 1.22 1.33 1.39 1.57 1.76 1.85 1.98
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 98.8 153 173 217 292 381
Power cons. in W 163 194 206 230 270 314
Current cons. in A 1.32 1.44 1.48 1.57 1.73 1.90
COP in W/W 0.61 0.79 0.84 0.94 1.08 1.21
ASHRAE LBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 113 167 188 232 308 400 470 510 639 791 866 968
Power cons. in W 155 179 188 205 234 265 286 296 329 362 376 394
Current cons. in A 1.51 1.58 1.61 1.66 1.75 1.84 1.91 1.94 2.05 2.16 2.21 2.28
COP in W/W 0.73 0.93 1.00 1.13 1.32 1.51 1.65 1.72 1.94 2.19 2.30 2.46
ASHRAE LBP 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 122 188 214 267 361 47 1
Power cons. in W 163 194 206 230 270 314
Current cons. in A 1.32 1.44 1.48 1.57 1.73 1.90
COP in W/W 0.75 0.97 1.04 1.16 1.34 1.50
Accessories for FR10G Figure Code number Test conditions
EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 55°C
Starting relay 6.3 mm spade connectors a2 117U6010 Suction gas temperature 32°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5015 Liquid temperature 55°C 32°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 16 m m 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.P2.02 / 520N1380 August 2012