Danfoss FR10G Data sheet

Danfoss FR10G Data sheet

FR10G

Universal Compressor

R134a

220-240V 50/60Hz

General

Code number

 

 

 

 

 

103G6890

 

 

Approvals

 

 

 

 

EN 60335-2-34, CCC

 

Compressors on pallet

 

 

 

 

 

80

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

LBP/HBP

 

 

 

LBP

 

Frequency

 

Hz

 

50

 

 

 

 

60

 

Evaporating temperature

 

°C

-30 to 10

 

-30 to -10

Voltage range

 

V

187 - 254

 

198 - 254

Max. condensing temperature continuous (short)

°C

 

60 (70)

 

60 (70)

Max. winding temperature continuous (short)

°C

125 (135)

 

125 (135)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

 

60

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

 

MBP

HBP

32°C

 

 

S

 

F2

F2

 

S

 

38°C

 

 

S

 

F2

F2

 

S

 

43°C

 

 

O

 

F2

F2

 

O

 

Remarks on application: HBP at 198 - 254V 50Hz only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

 

RSIR/CSIR

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

10.0

 

 

 

 

10.3

 

Cut in Current, HST | LST

 

A

 

10.0

 

 

 

 

15.0

 

Resistance, main | start winding (25°C)

 

7.3

 

 

 

 

12.0

 

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cm3

 

 

 

9.05

 

 

 

Oil quantity (type)

 

cm3

 

 

450 (polyolester)

 

Maximum refrigerant charge

 

g

 

 

 

900

 

 

 

Free gas volume in compressor

 

cm3

 

 

 

1350

 

 

 

Weight without electrical equipment

kg

 

 

 

10.6

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

mm

A

 

 

196

 

 

 

 

 

 

B

 

 

191

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

B2

 

 

 

 

 

Suction connector

location/I.D. mm | angle

C

 

 

8.2 | 30°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Process connector

location/I.D. mm | angle

D

 

 

6.2 | 30°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location/I.D. mm | angle

E

 

 

6.2 | 25°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Oil cooler connector

location/I.D. mm | angle

F

 

 

6.2 | 25°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Connector tolerance

I.D. mm

 

 

 

±0.09

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

= Static cooling normally sufficient

O

= Oil cooling

F1

= Fan cooling 1.5 m/s

 

 

 

 

(compressor compartment temperature

 

 

 

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

August 2012

Manufactured by Secop for Danfoss - DEHC.ED.400.P2.02 / 520N1380

1/2

EN 12900 Household (CECOMAF)

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

5

7.2

 

10

 

15

20

Capacity in W

 

 

 

 

91.9

136

152

188

250

324

380

412

516

638

697

 

779

 

 

 

Power cons. in W

 

 

 

 

155

179

188

205

234

265

286

296

329

362

376

 

394

 

 

 

Current cons. in A

 

 

 

 

1.51

1.58

1.61

1.66

1.75

1.84

1.91

1.94

2.05

2.16

2.21

 

2.28

 

 

COP in W/W

 

 

 

 

0.59

0.76

0.81

0.91

1.07

1.22

1.33

1.39

1.57

1.76

1.85

 

1.98

 

 

 

EN 12900 Household (CECOMAF)

 

220V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

5

7.2

 

10

 

15

20

Capacity in W

 

 

 

 

98.8

153

173

217

292

381

 

 

 

 

 

 

 

 

 

 

 

 

 

Power cons. in W

 

 

 

 

163

194

206

230

270

314

 

 

 

 

 

 

 

 

 

 

 

 

 

Current cons. in A

 

 

 

 

1.32

1.44

1.48

1.57

1.73

1.90

 

 

 

 

 

 

 

 

 

 

 

 

 

COP in W/W

 

 

 

 

0.61

0.79

0.84

0.94

1.08

1.21

 

 

 

 

 

 

 

 

 

 

 

 

 

ASHRAE LBP

 

 

 

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

5

7.2

 

10

 

15

20

Capacity in W

 

 

 

 

113

167

188

232

308

400

470

510

639

791

866

 

968

 

 

 

Power cons. in W

 

 

 

 

155

179

188

205

234

265

286

296

329

362

376

 

394

 

 

 

Current cons. in A

 

 

 

 

1.51

1.58

1.61

1.66

1.75

1.84

1.91

1.94

2.05

2.16

2.21

 

2.28

 

 

COP in W/W

 

 

 

 

0.73

0.93

1.00

1.13

1.32

1.51

1.65

1.72

1.94

2.19

2.30

 

2.46

 

 

 

ASHRAE LBP

 

 

 

 

220V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

5

7.2

 

10

 

15

20

Capacity in W

 

 

 

 

122

188

214

267

361

47 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Power cons. in W

 

 

 

 

163

194

206

230

270

314

 

 

 

 

 

 

 

 

 

 

 

 

 

Current cons. in A

 

 

 

 

1.32

1.44

1.48

1.57

1.73

1.90

 

 

 

 

 

 

 

 

 

 

 

 

 

COP in W/W

 

 

 

 

0.75

0.97

1.04

1.16

1.34

1.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories for

FR10G

Figure

Code number

 

 

 

 

PTC starting device

6.3 mm spade connectors

a1

103N0011

 

4.8 mm spade connectors

103N0018

 

 

Starting relay

6.3 mm spade connectors

a2

117U6010

Start. capacitor 80 µF

6.3 mm spade connectors

c

117U5015

Cover

 

b

103N2010

Cord relief

 

d

103N1010

Protection screen for PTC

 

g

103N0476

Test conditions

EN 12900/

ASHRAE

 

CECOMAF

 

Condensing temperature

55°C

55°C

Ambient temperature

32°C

32°C

Suction gas temperature

32°C

32°C

Liquid temperature

55°C

32°C

Mounting accessories

 

 

Code number

Bolt joint for one comp.

Ø: 16

mm

118-1917

Bolt joint in quantities

Ø: 16

mm

118-1918

Snap-on in quantities

Ø: 16

mm

118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.400.P2.02 / 520N1380

August 2012

Loading...