Danfoss FHM-CN1 Installation guide

Installation Guide
FHM-CN1
Pre-assembled Mixing Shunt
Installation overview
Installation procedure
The FHM-CN1 must be connected to a system according to the illustrations.
2. Pre-mounted union nut for connection to the secondary side pipe or directly on a Danfoss manifold. The nut to mixing shunt must be tightened with a torque of 30 to 40 Nm with enclosed flat gasket.
3. FTC thermostatic sensor is in package. Mount it on the valve according to the enclosed instruction.
A
Flow of primary side
B
Flow of secondary side
C
Return of primary side
D
Return of secondary side
A
C
B
D
© Danfoss | FEC | 2020.05
AN17778646158801-000201 / 088U7200 | 1
Installation Guide FHM-CN1 Pre-assembled Mixing Shunt
Tips
RoHS compliance
1. If the primary side pipe is coming from the bottom, the bend 4 (088U0821) can be ordered as an accessory. The bend must be tightened to the mixing shunt with a torque of 30 to 40 Nm.
B
2. Connection 5 and 6 are tightened from the factory. If leaks occur due to loosening during transportation, moving or similar, please tighten:
• connection 5 at a torque of at least 85 Nm
• connection 6 at a torque of 30 to 40 Nm
A
Flow of primary side
B
Flow of secondary side
C
Return of primary side
D
Return of secondary side
Part Name
A
C
Hazardous Substances Table
Pb Hg Cd Cr(VI) PBB PBDE
D
Pump X O O O O O
Brass parts X O O O O O
O: Indicates that this hazardous substance contained in all of the homogeneous material for this
part is below the limit requirement in GB/T 26572.
X: Indicates that this hazardous substance contained in at least one of the homogeneous material
for this part is above the limit requirement in GB/T 26572.
2 | © Danfoss | FEC | 2020.05
AN17778646158801-000201 / 088U7200
安装指南
FHM-CN1
整体式混水中心
I安装概览
安装步骤
必须按图示要求将 FHM-CN1 连接至系统。
先将图中所示活接(1)装到一次侧供水管上。 再将活接与控制阀进行连接,并用不小于 85 Nm的力 矩拧紧螺母, 该活接与阀体的连接为硬密封,连接时勿需使用任何密封材料。
将图中所示活接(2)先装到二次侧供回水管上或丹佛斯分集水器上。 再将活接与混水中心连接,密封 材料为产品附带的密封平垫片,并用 30-40 Nm 的力矩拧紧螺母。
FTC 恒温阀头在包装内。 根据随附说明将其安装到阀门上。
A
B
C
D
一次侧供水
二次侧供水
一次侧回水
二次侧回水
A
C
B
D
© Danfoss | FEC | 2020.05
AN17778646158801-000201 / 088U7200 | 3
Danf
小贴示
1. 如果一次侧供回水管是底进底出,可订购活接 弯头(4) (088U0821) 进行连接。 活接弯头与 混水中心连接的螺母应用 30-40 Nm 的力矩 拧紧。
2. 连接螺母(5)和(6)在出厂时已拧紧。 如果由于 在运输、搬运或类似过程中出现松动而导致泄 漏的话,请:
• 用不小于85 Nm 的力矩拧紧螺母(5)
• 用30-40 Nm 的力矩拧紧螺母(6)
A
一次侧供水
B
二次侧供水
C
D
一次侧回水
二次侧回水
A
B
D
C
RoHS 指令
部件名称
水泵
铜制部分
O:
表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定的限量要求以下。
X:
表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572规定的限量要求。
六价铬 多溴联苯 多溴二苯醚
X O O O O O
X O O O O O
有害物质含量表
丹佛斯自动控制管理(上海)有限公司 地址:上海市宜山路900号科技大楼C楼22层邮编:200233 电话:+86 21 61513000 传真:+86 21 61513100 电子邮件: heating@danfoss.com http://heating.danfoss.cn
oss Danfoss
Danfoss ઼ᡰᴹ Danfoss Danfoss A/S( )
4 | © Danfoss | FEC | 2020.05
AN17778646158801-000201 / 088U7200