Danfoss EV224B Data sheet

Data Sheet
Solenoid valve Type EV224B
Servo operated valve for air with oil for high pressure applications
EV224B for compressed air, is a high pressure indirect servo-operated 2/2-way solenoid valve with working pressure up to 40 bar, medium temperature up to 60 °C and available in NC and NO versions.
Built-in pilot lter as standard, replaceable equalizing orice, enclosures up to IP67 (depending on coil) ensure a reliable and satisfactory function.
Features
• For compressed air and compressed air with mineral oil
• Clip on coil
• Ambient temperature: Up to 60 °C
• Coil enclosure: Up to IP67
• Built in lter for protection of pilot system
AI260151589548en-001301
Features
EV224B
Body material
Brass
DN [mm]
15 - 25
Connection
G
1
2'' - G1''
Sealing material
NBR
Function
NC, NO
Kv [m3/h]
4 - 11
Dierential pressure range [bar]
0.3 - 40
Temperature range [°C]
-10 - 60
Solenoid valve, Type EV224B
1 Portfolio overview
Table 1: Portfolio overview
© Danfoss | Climate Solutions | 2021.06 AI260151589548en-001301 | 2
7
DANFOSS
32U846_11
1.2.3.4.5.6.7.
Coil
Armature spring
Valve plate
Pilot orice
Diaphragm
Main orice
Equalizing orice
Solenoid valve, Type EV224B
2 Functions
2.1 Function NC
Coil voltage disconnected (closed)
When the voltage is disconnected, the valve plate (3) is pressed down against the pilot orice (4) by the armature spring (2). The pressure across the diaphragm (5) is built up via the equalizing orice (7). The diaphragm closes the main orice (6) as soon as the pressure across the diaphragm is equivalent to the inlet pressure. The valve will be closed for as long as the voltage to the coil is disconnected.
Coil voltage connected (open)
When voltage is applied to the coil (1), the pilot orice (4) is opened. As the pilot orice is larger than the equalizing orice (7), the pressure across the diaphragm (5) drops and therefore it is lifted clear of the main orice (6). The valve
is now open for unimpeded ow and will be open for as long as the minimum dierential pressure across the valve is maintained, and for as long as there is voltage to the coil.
Figure 1: Function NC
2.2 Function NO
Coil voltage disconnected (open)
When the voltage to the coil (2) is disconnected, the pilot orice (4) is open. As the pilot orice is larger than the equalizing orice (7), the pressure across the diaphragm (5) drops and therefore it is lifted clear of the main orice (6). The valve will be open for as long as the minimum dierential pressure across the valve is maintained, and for as long as the voltage to the coil is disconnected.
Coil voltage connected (closed)
When voltage is applied to the coil, the valve plate (3) is pressed down against the pilot orice (4). The pressure across the diaphragm (5) is built up via the equalizing orice (7). The diaphragm closes the main orice (6) as soon as the pressure across the diaphragm is equivalent to the inlet pressure. The valve will be closed for as long as there is voltage to the coil.
© Danfoss | Climate Solutions | 2021.06 AI260151589548en-001301 | 3
DANFOSS
32U956
7
1.2.3.4.5.6.7.
Coil
Armature spring
Valve plate
Pilot orice
Diaphragm
Main orice
Equalizing orice
Solenoid valve, Type EV224B
Figure 2: Function NO
© Danfoss | Climate Solutions | 2021.06 AI260151589548en-001301 | 4