Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
SCADA
Energy meters supported by Danfoss SCADA
solutions, Leanheat® Monitor and ECL Comfort 296/310
Energy meters Leanheat®
Monitor
Danfoss
Sonometer 1100
Danfoss
SonoSelect 10/
SonoSafe 10
Danfoss
Sonometer 30
Danfoss
Sonometer 31
Danfoss
SonoSensor 30
Danfoss
SONO 3500 CT
Danfoss
Infocal 5
Danfoss
Infocal 6
Danfoss
Infocal 8
Danfoss
Infocal 9
ABB
“Odin” OD4110
ABB
“Delta” DBM
2300
Actaris, Allmess,
Itron CF51
Actaris, Allmess,
Itron
CF55
Actaris, Allmess,
Itron
CF Echo II
( ) ( ) ( ) ( ) ( )
( ) ( ) ( ) ( ) ( )
ECL Comfort 296 /
310
ECL Portal DECS 2.0 OPC Server
( )
Supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
(
© Danfoss | 2021.09
Click on the icons in the table to get more information.
Partly supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
Click on the icons in the table to get more information.
)
Not supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
Click on the icons in the table to get more information.
Blank field means ‘not tested’.
AI150386468396en-010801 | 1
Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
Energy meter overview (continued)
Energy meters Leanheat®
Monitor
Axis Industries
SKS-3
Axis Industries
Enco Pulse
Brunata
HGQ
Carlo Gavazzi
EM33-DIN
EMH Metering
KIZ W 1E LKOM-11-E50/K
Engelmann
SensoStar2
Hydrometer /
Diehl
Sharky 775
Hydrometer /
Diehl
Hydros
Itron
Cyble v1.4
Itron
Cyble v2.0
Kamstrup
Multical 21
Kamstrup
Multical 62
Kamstrup
Multical 382
Kamstrup
Multical 401
Kamstrup
Multical 402
Kamstrup
Multical 601
Kamstrup
Multical 602
Kamstrup
Multical 801
ECL Comfort 296 /
310
ECL Portal DECS 2.0 OPC Server
Supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
(
2 | © Danfoss | 2021.09
Click on the icons in the table to get more information.
Partly supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
Click on the icons in the table to get more information.
)
Not supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
Click on the icons in the table to get more information.
Blank field means ‘not tested’.
AI150386468396en-010801
Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
Energy meter overview (continued)
Energy meters Leanheat®
Monitor
Kamstrup
SVM F4
Landis & Gyr
2WR5
Landis & Gyr
UltraHeat 50
Saia
ALD1D5FM
Saia
ALE3D5FM
Sensus
HRI
Supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
(
General considerations • As the M-bus data communication requires a
Click on the icons in the table to get more information.
Partly supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
Click on the icons in the table to get more information.
)
Not supported by Danfoss SCADA solutions and/or ECL Comfort 296 / 310.
Click on the icons in the table to get more information.
ECL Comfort 296 /
310
certain power it is recommended to use
mains powered energy meters.
• Some energy meters have an option of high
energy battery (like Sonometer 1100 D-Cell)
which enables frequent communication.
This kind of battery powered meters can be
used.
ECL Portal DECS 2.0 OPC Server
Blank field means ‘not tested’.
• Energy meters are considered to be
supported when energy, volume, flow rate,
power, supply and return temperature can
be read by the ECL Comfort 296 / 310 /
SCADA software.
• Only systems using the ECL Comfort 296 /
310 controller are evaluated.
AI150386468396en-010801
• Energy meter must not disable M-bus data
communication and / or enter into battery
saving mode if data is requested too
frequently by the controller or SCADA
software, i.e. each 60 seconds.
© Danfoss | 2021.09 | 3
Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
Details on specific
combinations
Danfoss Sonometer 1100
• Setup/configuration of meter may be required
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Danfoss SonoSelect 10 / SonoSafe 10
• Setup/configuration of meter may be required
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Danfoss Sonometer 30
• Setup/configuration of meter may be required
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
* AC mains power supply required
• ECL Comfort 296 / 310 must be version 1.60 or newer
• Sample interval > 900 seconds to respect battery lifetime requirements
Danfoss Sonometer 31
• Setup/configuration of meter may be required
• Flow/volume data only supported for meter ordered with U1/q1 input
* Required for support of flow/power limitation with ECL Comfort 296 / 310
* AC mains power supply required
• ECL Comfort 296 / 310 must be version 1.60 or newer
• Sample interval > 900 seconds to respect battery lifetime requirements
• Ordered with U2/q2 input: Flow and volume data not supported
Danfoss Infocal 5
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Danfoss Infocal 6
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Danfoss Infocal 8
• Setup/configuration of meter may be required
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Danfoss Infocal 9
• Setup/configuration of meter may be required
• Flow/volume data only supported for meter ordered with U1/q1 input
* Required for support of flow/power limitation with ECL Comfort 296 / 310
* AC mains power supply required
• ECL Comfort 296 / 310 must be version 1.60 or newer
• Sample interval > 900 seconds to respect battery lifetime requirements
• Ordered with U2/q2 input: Flow and volume data not supported
4 | © Danfoss | 2021.09
ABB “Odin” OD4110
• Preliminary test results. Tests not yet completed
• Meter must not communicate with both ECL Comfort 296 / 310 and ECL Portal
AI150386468396en-010801
Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
Details on specific
combinations (continued)
ABB “Delta” DBM 2300
• Preliminary test results. Tests not yet completed
• Meter must not communicate with both ECL Comfort 296 / 310 and ECL Portal
Actaris, Allmess, Itron CF51
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
• Sample interval > 900 seconds to respect battery lifetime requirements
Actaris, Allmess, Itron CF55
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
• Sample interval > 900 seconds to respect battery lifetime requirements
Actaris, Allmess, Itron CF Echo II
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 must be version 1.46 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
• Sample interval > 900 seconds to respect battery lifetime requirements
Axis Industries SKS-3
• Sample interval > 900 seconds to respect battery lifetime requirements
Axis Industries Enco Pulse
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 must be version 1.20 or newer
Brunata HGQ
• Meter must not communicate with both ECL Comfort 296 / 310 and ECL Portal
Carlo Gavazzi EM33-DIN
• No comments
EMH Metering KIZ W1EL-KOM-11-E50/K
• Meter must not communicate with both ECL Comfort 296 / 310 and ECL Portal
Engelmann SensoStar2
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Hydrometer / Diehl Sharky 775
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Hydrometer / Diehl Hydros
• ECL Comfort 296 / 310 must be version 1.40 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Itron Cyble v1.4
• No comments
AI150386468396en-010801
Itron Cyble v2.0
• ECL Comfort 296 / 310 must be version 1.42 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
© Danfoss | 2021.09 | 5
Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
Details on specific
combinations (continued)
• ECL Comfort 296 / 310 must be version 1.20 or newer
Kamstrup Multical 21
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 supported with limitations
• ECL Comfort 296 / 310 must be version 1.42 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Kamstrup Multical 62
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
• Values not supported by Multical 62 will be shown as 0 and 180, respectively
Kamstrup Multical 382
• Preliminary test results. Tests not yet completed
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 must be version 1.42 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Kamstrup Multical 401
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Kamstrup Multical 402
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Kamstrup Multical 601
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Kamstrup Multical 602
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.10 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Kamstrup Multical 801
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Kamstrup SVM F4
• Preliminary test results. Tests not yet completed
• Meter must not communicate with both ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.42 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Landis & Gyr 2WR5
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
6 | © Danfoss | 2021.09
Landis & Gyr UltraHeat 50
• Supports flow/power limitation with ECL Comfort 296 / 310 and ECL Portal
• ECL Comfort 296 / 310 must be version 1.20 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
AI150386468396en-010801
Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
Details on specific
combinations (continued)
• Setup/configuration of meter may be required
Saia ALD1D5FM
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 supported with limitations
• ECL Comfort 296 / 310 must be version 1.42 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Saia ALE3D5FM
• Setup/configuration of meter may be required
• ECL Comfort 296 / 310 supported with limitations
• ECL Comfort 296 / 310 must be version 1.42 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
Sensus HRI
• ECL Comfort 296 / 310 supported with limitations
• ECL Comfort 296 / 310 must be version 1.42 or newer
• DECS 2.0 software must be version 2.0.25B or newer
• OPC Server software must be version 3.53.0.56 - Release 1 or newer
AI150386468396en-010801
© Danfoss | 2021.09 | 7
Appendix to data sheets on ECL Comfort 296 / 310, ECL Portal, Leanheat® Monitor, heat meters and DECS 2.0
8 | © Danfoss | DCS-SGDPT/DK | 2021.09