Data sheet
Temperature Sensors
CANopen & SAE J1939
The DST T92C OEM temperature transmitter
is designed for use in harsh environments as
Mobile hydraulic applications.
Danfoss DST T92C is designed to comply with
CANopen as well as SAE J1939.
It is a cost effective way to control complex
machines and make also replacements
cost- effiient while offering additional benefits
such as diagnostic and communication.
The DST T92C is with E1 type approval (vehicles
and vehicle parts according to European
directives for use on public roads).
The DST T92C is offered with a measuring range
of -40 – 150 °C.
Features
Approvals
• Designed for use in off-highway vehicles
• For ambient temperatue up to 125 °C
• Measuring range -40 – 150 °C
• CANopen
• SAE J1939
• Wetted parts made of stainless steel
• Fully welded design and therefore no use of
gasket in combination with wetted parts
• CE marked
• E1 type approval
Note: In respect to Customer Change Notification, only changes in relation to Form Fit and
Function can be informed upon!
© Danfoss | DCS (im) | 2018.08
IC.PD.P40.B3.02 | AI267741988326en-000301 | 1

Data sheet | Temperature Transmitter DST T92C
Technical data
General data
Measuring range -40 – 150 °C
Overall accuracy
0.6% FS [-40 –125° C]
0.4% FS [-40 – 85° C]
Response times
Indicative response times
Type
Water 0.2 m/s Air 2 m/s
t
0.5
t
0.9
t
0.5
DST T92C reaction time (guidance values) 4 s. 9.6 s. 45 s. 160 s.
Environmental and mechanical data
Media temperature range -40 – 150 °C
Ambient temperature range -40 – 125 °C
Storage temperature range -40 – 125 °C
Voltage supply 9 – 36 V
Electrical Protection Short circuit reverse polarity protection
EMC EN 61326-1
Vibration stability
Shock mechanical 50 g /11 ms, 30 g/6ms, 300 g EN60068-27
Enclosure
Material with media contact 1.4571, 1.4542/P1070, FKM
Weight 75 g
Enclosure IP67
CAN
20 g EN 60068-2-6
Random ISO16750-3
1.4301/PBT-GF30
Bitrate CANopen: 125 kbit/s, configurable SAE J1939:250 kbit/s
Digital filter averaging filter, configurable for CANopen
Output protocol Danfoss-CAN, CANopen, SAE J1939
t
0.9
Electrical connection M12 connector, DIN Bayonet (DIN 72585), DT04-4 p
2 | IC.PD.P40.B3.02 | AI267741988326en-000301
© Danfoss | DCS (im) | 2018.08

Data sheet | Temperature Transmitter DST T92C
Ordering standard
DST T92C - - - -
External sealing
···
Fluorocarbon FKM ≥ -20°C to ≤ 125°C (Viton)
1
Measuring range
-40 – 150° C·····························································-···
Output signal
CANopen ·····················································································
SAE J1939·····················································································
T2
Process connection
·······
GB04
Z
S
G¼ DIN 3852-E
Electrical connection
M12x1, 5 p
·······
EA
Deutsch, DT04-4 p
·······
EB
Bayonet, 4 pin DIN 72585, 4 pole
·······
B3
© Danfoss | DCS (im) | 2018.08
IC.PD.P40.B3.02 | AI267741988326en-000301| 3

Data sheet | Temperature Transmitter DST T92C
Dimensions / Combinations
Type code EA B3 EB
M12x1, 5-pol Bayonet, DIN 72585,
4pole
ø23.5
Deutsch, DT04-4 p
35.6
ø21.3
HEX 22
24.5
G 1\4
Type G ¼, DIN 3852-E
Gasket 16.5 x 11.6 x 1.5 FKM
Type code GB04
43.7
Danfoss
t
16.5 x 11.6 x 1.5
Recommended torque < 35 Nm
4 | IC.PD.P40.B3.02 | AI267741988326en-000301
© Danfoss | DCS (im) | 2018.08

Data sheet | Temperature Transmitter DST T92C
Electrical connections
Type code
Pin-plating Au plating on
CAN Pin 1: PE, Housing
EA B3 EB
M12x1, 5-pole Bayonet
Nickel
Pin 2: VCC
Pin 3: GND
Pin 4: CAN_H
Pin 5: CAN_L
23
PBT OF 30
DIN 72585, 4-pole
Tin plating on
Nickel
Pin 1: VVC
Pin 2:GND
Pin 3: CAN_H
Pin 4: CAN_L
4 1
3 2
Deutsch
DT04-4 p
Tin plating on
Nickel
Pin 1: CAN_L
Pin 2: VCC
Pin 3: GND
Pin 4: CAN_H
Recommended terminal layout
Danfoss
078G16
PE
VCC
GND
CAN_H
CAN_L
© Danfoss | DCS (im) | 2018.08
IC.PD.P40.B3.02 | AI267741988326en-000301| 5

© Danfoss | DCS (im) | 2018.08