Installation guide
Pressure transmitters
DST P1XX
<![endif]>075R0013
Electrical connection: |
See product label |
Electrisk tilslutning: |
Se produktskilt |
Elektrischer Anschluss: |
Siehe Produktschild |
Raccordement électrique: |
Voir étiquette du produit |
Conexión eléctrica: |
Ver la pegatina en el producto |
Connessione elettrica: |
Vedi etichetta sulla confezione |
Electrical |
Elektrisk |
Der elektrische |
Le transmetteur |
connector has |
tilslutning skal |
Anschlusss- |
de pression doit |
to be mounted |
tilsluttes |
tecker muss am |
être raccordé |
on the Pressure |
tryktransmitteren |
Drucktransmitter |
électriquement |
Transmitter |
før der kommer |
montiert werden, |
avant que |
before pressure |
tryk på |
bevor Druck |
l’application |
is added on the |
applikationen |
auf die Anlage |
ne soit sous |
application |
|
gegeben wird |
pression |
El conector |
Il connettore |
eléctrico |
elettrico deve |
tieneque estar |
essere montato |
montado en el |
sul Trasmettitore |
transmisor de |
di pressione |
presión antes |
prima che venga |
de que se añada |
applicata |
presión en la |
pressione sul |
aplicación |
sistema |
M12 x 1, 4 pin(1) |
Metri-Pack 150 |
AMPseal 16 |
Deutsch DT04, 4pin |
<![if ! IE]> <![endif]>Danfoss 64G101 |
|
<![if ! IE]> <![endif]>Danfoss 64G102 |
|
4 pole |
|
|
|
ISO 15170, |
|
|
|
Bayonet(2) |
|
|
|
|
|
DST P1XX |
|
(1)Tightening torque between electrical connector and mating connector (e.g. adaptor, cable, etc) is limited. Recommended is 0,5Nm and the maximum is 1,2Nm.
(2)Maximum tightening torque is 1,2Nm as per the ISO standard.
American and Canadian approvals:
Must be powered by Class 2 power supply
1.Automatic electrical controls acc. to UL 60730-1 and part 2-6 /CAN/CSA E60730 and part 2-6, file E31024.
2.Equipment for process measurement and control acc. to UL 61010-1 / CSA C22.2 No. 61010-1-12, file E494625.
3.Nonincendive electrical equipment for use in Class I, Div. 2, Groups A, B, C & D harzarous locations in acc. to UL 121201 / C22.2 No. CSA-213, file E510763.
4.The MWP 50 bar (max. working pressure))’
5.Evaluated for pollution Degree 2
6.Altitude up to 8000 m
7.Max. R.H. 95% non-condensing
8.Overvoltage category I
<![endif]>075R0013
© Danfoss | Climate Solutions | 2021.03 |
AN31455060087901-000602 | 1 |