Notes
devifl exTM DSIA heating cable and devimatTM
devifl exTM and devimatTM DSIA heating cable/mat is used for ice and snow melting of outdoor area and other applications with embedding in concrete
This instruction covers ice and snow melting of outdoor areas.
Should you require further information about other areas of use please consult our DEVI heating cable compendiums
Specifi cations
Mat |
devimatTM DSIA-300 (300 W/m2) |
|
|
Cable |
devifl exTM DSIA-25 (25 W/m) |
|
|
Type |
Single-conductor with screen and armour |
||
Voltage |
230 or 400 V AC (check the lable) |
|
|
Diameter |
Ø 5,5 mm. |
Connections |
|
Cold tai |
2 x 4 m, 2 x 1,5 mm2 + screen |
||
Conductor insulation |
XLPE (Polyethylene) |
Phase 1 - Black |
|
Sheath |
PVC 90ºC |
||
Phase 2 - Black |
|||
Max. temperature |
60ºC |
||
Ground - Screen |
|||
Deformation strength |
2000 N (IEC 800 Class C) |
||
|
Areas of use
The table shows a variety of areas |
Area of use |
Effect W/m² |
where the heating cable or mat is |
|
|
used and the required effects in |
|
|
connection with ice and snow melting |
|
|
ins. = insulated
Warning!
The system must be disengaged at temperatures of more than +10ºC.
The cable must not be shortened or cut in any manner or subjected to strain at the cable connection.
Connecting the cable or mat to the mains must be undertaken by an authorised electrician