Danfoss DSIA-300, DSIA-25 Operating guide [tr]

Danfoss DSIA-300, DSIA-25 Operating guide

GB/DAS

Installation Instructions

 

devimatTM DSIA-300

 

devifl exTM DSIA-25

 

single-conductor heating cable

 

for outdoor applications, 230V or

 

400V

Notes

devifl exTM DSIA heating cable and devimatTM

devifl exTM and devimatTM DSIA heating cable/mat is used for ice and snow melting of outdoor area and other applications with embedding in concrete

This instruction covers ice and snow melting of outdoor areas.

Should you require further information about other areas of use please consult our DEVI heating cable compendiums

Specifi cations

Mat

devimatTM DSIA-300 (300 W/m2)

 

Cable

devifl exTM DSIA-25 (25 W/m)

 

Type

Single-conductor with screen and armour

Voltage

230 or 400 V AC (check the lable)

 

Diameter

Ø 5,5 mm.

Connections

Cold tai

2 x 4 m, 2 x 1,5 mm2 + screen

Conductor insulation

XLPE (Polyethylene)

Phase 1 - Black

Sheath

PVC 90ºC

Phase 2 - Black

Max. temperature

60ºC

Ground - Screen

Deformation strength

2000 N (IEC 800 Class C)

 

Areas of use

The table shows a variety of areas

Area of use

Effect W/m²

where the heating cable or mat is

 

 

used and the required effects in

 

 

connection with ice and snow melting

 

 

ins. = insulated

Warning!

The system must be disengaged at temperatures of more than +10ºC.

The cable must not be shortened or cut in any manner or subjected to strain at the cable connection.

Connecting the cable or mat to the mains must be undertaken by an authorised electrician

Loading...