Fact Sheet
DSA HOME
District heating substation up to 25 / 40 kW
1)
FEATURES AND BENEFITS
• Substation with high efficiency
brazed plate heat exchangers
for one family houses, made
from acid-proof stainless steel
• Wall-mounted construction
• Suitable for new buildings as
well as renovation projects
• Small, lightweight,
compact construction
• Electronic controllers for heating
and domestic hot water systems
• Fast and reliable delivery
• Fast and easy installation
• Danfoss substations and heat
exchangers are manufactured
according to European Pressure
Directive PED 2014/68/EU
Application
The DSA HOME is designed for use in
high-parameter district heating networks. Suitable for heating single houses. It provides an alternative solution
to an oil or gas boiler. The DSA Home
is designed for heating or heating and
domestic hot water. The wall-mounted
construction saves space needed for
installation and servicing.
Flexibility
The new DSA HOME is offered as 1- or
2- circuit module. In addition, primary
modules (including ball valves, strainers,
differential pressure regulators and heat
meters) can be ordered as accessories.
Primary modules can be connected to
either the right or the left side, without
any modification to the construction.
Construction / Installation
The DSA HOME is designed as a wallmounted station. Each station is
equipped with micro plate heat exchangers manufactured by Danfoss,
which significantly increase substation
performance and lifetime. All components are placed at the front of the station, which makes it very easy to access
them during maintenance or servicing.
Due to the Euro-pallet size, it is possible to transport the DSA HOME with
a small van. The mounting equipment
significantly reduces the time required
to mount the substation to the wall.
The standard station layout means that
the piping can easily be prepared in
the room where the substation is to be
installed before the substation is delivered, which reduces the time between
delivery and start-up. Piping prepared
with automatic welding machines
ensures the highest possible welding
quality.
Equipment
The DSA HOME offers a wide variety of
additional accessories, such as substation cover or primary modules. It can
deliver with neither with ECL310 with
communication functionality or with
ECL110 .
Information needed
for a quotation
• Heat capacities
• Temperature programme
• Permissible pressure losses in the
heat exchangers / substations
• Primary pressure difference available
• Pressure losses in secondary circuits
• Flow-through hot water circulation
• Other information about other
required components
1) Maximum capacity is determined by temperature,
allowable pressure drops and local regulations.
www.danfoss.com

CIRCUIT DIAGRAM – EXAMPLE
G3, G4 Shut-off valve
Scw Control valve DHW
Sco Control valve HE
Z1 Shut-off valve
TM2 Thermomanometer
F2 Strainer
PO Heating pump
Tco Temp. sensor HE
ZBO Safety valve HE
Tcw Temp. sensor DHW
G6 Shut-off valve
G9 Check valve
ZBW Safety valve DHW
F3 Strainer
G5 Shut-off valve
G8 Check valve
PC Circulation pump
G7 Shut-off valve
FQ1 Watermeter
ZUZ Refilling valve
W Elastic Hose
G1 Shut-off valve
TM1 Thermomanometer
F1 Strainer
DPV dP controller
LC Heatmeter
Technical paremeters
Primary side
Maximum temperature: 130 °C
Nominal pressure: PN 16
Diameter (threaded): DN 20
Heating
Maximum temperature: 100 °C
Nominal pressure: PN 6
Diameter (threaded): DN 20
Domestic Hot Water
Maximum temperature: 90 °C
Nominal pressure: PN 10
Diameter (threaded): DN 15 / 15
Max dimensions (mm)
Width / Height / Depth (1F): 500 / 810 / 350 mm
Width / Height / Depth (2F): 800 / 810 / 350 mm
Weight (incl. packing)
1-circuit station: max. 24 kg
2-circuit station: max. 35 kg
SPECIFICATION
Typ e
DSA HOME 1F-1
DSA HOME 1F-2
DSA HOME 1F-3
DSA HOME 2F-1
DSA HOME 2F-2
DSA HOME 2F-3
DSA HOME 2F-4
Capacity [kW] Control valve Heat exchanger
HE
DHW HE DHW HE DHW HE DHW
–
– – – –
– – –
25
40
1
800
2
VS 2 DN15 / 1,0
6 5 3 4
7
800
–
AVTQ 15 / 1,6
VM 2
XB06L-1-16
DN15/2,5
–
XB06H-1-20
Additional accessories
and options:
- Primary side module (which may
include ball valves, strainer, differential pressure controller, heat meter,
thermometers and manometers)
Connections:
1. District Heating Supply
1
2. District Heating Return
3. Heating Supply
4. Heating Return
5. Domestic Hot Water
6. Domestic Cold Water
7. Circulation
2
Pump
–
UPM3AUTO
15-70
–
–
UPM3
DHW 15-20
Controller
ECL110
ECL310
ECL110
ECL310
© Danfoss | DHS-SMTL/ PL | 2018 .10
VL.MG.L1.02