Danfoss DEVIpipeguard 10 LSZH, DEVIpipeguard 25 LSZH, DEVIpipeguard 33 LSZH Data sheet

6. Pipe tracing
Data Sheet
DEVIpipeguard™
DEVIpipeguard™ 10 LSZH, DEVIpipeguard™ 25 LSZH, DEVIpipeguard™ 33 LSZH
The DEVIpipeguard™ LSZH is a halogen free self-limiting heating cable that is mainly used for frost protection of pipes. The self-limiting capability of the cable ensures that the output of the cable increase or decrease according to ambient temperature. The cable will maintain its functionality even when shortened.
The outer sheath is highly resistant to harsh environmental conditions and corrosion and it also serves as a protection against mechanical influences. All self-limiting heating cables must be over-temperature protected by a thermostat, as the output will decrease, but never be zero.
The cables are not approved for use in drinking water.
Benefits:
Cut to length on site
PVC free
Standard compliance:
• EN 62395-1: 2013
• EN 60754-1: 2014
• EN 60754-2: 2014
• EN 6103-2:2005/A1:2013
Approvals:
Type
Nominal voltage 230 V AC
Nominal output (min-max): DEVIpipeguard™ 10 LSZH DEVIpipeguard™ 25 LSZH DEVIpipeguard™ 33 LSZH
Maximum permissible use temperature
Minimum installation temperature -5 °C
Cable dimensions 13,6 × 5,8 mm
Outer sheath: DEVIpipeguard™ 10 LSZH DEVIpipeguard™ 25 LSZH DEVIpipeguard™ 33 LSZH
Screen Tinned copper braid
Minimum braid coverage 70%
Maximum resistance protective braid 18,2 Ω/Km
Bending Ø, min. 64 mm (Ø to the inside of the tape)
IP Class IPX7
Value
10 W/m @ 10 °C (9,8-14,7 W/m @ 10 °C) 25 W/m @ 10 °C (23,6-32,8 W/m @ 10 °C) 33 W/m @ 10 °C (32,0-39,7 W/m @ 10 °C)
65 °C, powered
85 °C, unpowered
Types DEVIpipeguard™ 10 LSZH
Item no. Length Min-max length
per drum
98301063 Drum, 100 m 90-110 m 1 10 W/m 5703466249604 98301064 Drum, 250 m 250 m 1 10 W/m 5703466249611 98301065 Drum, 750 m 675-825 m 98301071 Cut-to-length (up to 750 m) -
Number of length
allowed on drum, max
3 10 W/m 5703466249628
- 10 W/m 5703466249697
Nominal output
@ 10 °C
EAN no.
Blue, TPE
Red, TPE
Grey, TPE
Types DEVIpipeguard™ 25 LSZH
Item no. Length Min-max length
per drum
98301066 Drum, 100 m 90-110 m 1 25 W/m 5703466249635 98301067 Drum, 250 m 250 m 1 25 W/m 5703466249642 98301068 Drum, 750 m 675-825 m 3 25 W/m 5703466249659 98301072 Cut-to-length (up to 750 m) - - 25 W/m 5703466249703
Number of length
allowed on drum, max
Nominal output
@ 10 °C
EAN no.
Types DEVIpipeguard™ 33 LSZH
Item no. Length Min-max length
per drum
98301069 Drum, 250 m 250 m 1 33 W/m 5703466249666 98301073 Cut-to-length (up to 250 m) - - 33 W/m 5703466249710
RCD of 30 mA is required, max. 500 m of self-limiting heating cable per RCD.
Number of length
allowed on drum, max
Nominal output
@ 10 °C
EAN no.
Produced by Danfoss ©AI371348 416245en -010103
Maximum heating circuit length on a pipe, with circuit breaker with C-characteristic
DEVIpipeguard™ 10 LSZH
Switch on
temperature
10 °C 10 119 191 226 226 226 25 58 93 116 146 146 33 42 67 84 105 120
0 °C 11,7 119 191 226 226 226 28,6 58 93 116 146 146 37,5 36 58 73 91 117
-10 °C 13,3 110 176 220 226 226 32,3 52 84 105 131 146 42 32 51 64 81 103
10 A 16 A 20 A 25 A 32 A 10 A 16 A 20 A 25 A 32 A 10 A 16 A 20 A 25 A 32 A
Power W/m
DEVIpipeguard™ 25 LSZH
Power W/m
DEVIpipeguard™ 33 LSZH
Power W/m
-20 °C 15 97 156 195 226 226 35,9 46 74 93 116 146 46,5 28 45 57 71 91
-30 °C 16,7 87 140 175 219 226 39,5 42 67 84 105 134 51 25 41 51 64 82
-40 °C 18,3 80 127 159 199 226 43,1 38 61 76 95 122 55,5 23 37 47 58 75
Power output characteristic
Output of heating cable installed and measured on a pipe.
W/m
40
35
30
25
20
DEVIpipeguard™ 33 LSZH
DEVIpipeguard™ 25 LSZH
DEVIpipeguard™ 10 LSZH
15
10
5
0
0 10 20 30 40 50 60
Pipe temperature (°C)
Produced by Danfoss ©AI371348 416245en -010103