1�1 Technical Specifications
Operation voltage230 VAC/15 V DC ±10%
Ambient temperature-10 to +40 °C
Storage temperature-20 to +65 °C
Ball pressure test temperature
Pollution degree2 (domestic use)
Transmission frequency868.42 MHz
Transmission rangeup to 30 m in normal
Max. repeaters in a chain3
Transmission powerMax. 1 mW
Software classA
IP class21
Length of mains cable3.0 m
75 °C
buildings
3Installation Guide
DEVIlink™ RU
DimensionsDimensions 125 x 107 x
Weight100 g
Electrical safety and Electro-Magnetic Compatibility for
this product is covered by the compliance with the EN/IEC
Standard “Automatic electrical controls for household and
similar use”:
▪ EN/IEC 60730-1 (general)
▪ EN/IEC 60730-2-9 (thermostat)
LED Indicator (red)
Round front Cover hidding push button
Transformer/power supply plug
25 mm
Installation Guide4
DEVIlink™ RU
1�2 Safety Instructions
Make sure the power supply to the thermostat is turned off
before installation.
Please also note the following:
▪ The installation of the thermostat must be done by an
authorized and qualified installer according to local
regulations.
▪ The thermostat must be connected to a power supply
via an all-pole disconnection switch.
▪ Always connect the thermostat to continuous power
supply.
▪ Do not expose the thermostat to moisture, water,
dust, and excessive heat.
2 Mounting Instructions
After the Repeater Unit has been assigned to the Controller,
disconnect the temporary 230 V power supply and mount
the Repeater Unit on the right location.
Push button
Back plate
Hole for releasing front cover
Back plate lock/unlock (Unbrako)
5Installation Guide
DEVIlink™ RU
Screw hole for wall mounting
3 Settings
Configuring of the DEVIlink™ RU Repeater Unit to the
DEVIlink™ CC by adding to it as a service device. See the
DEVIlink™ CC manual for further information.
3�1 Initiate transmission test on the Repeater Unit
▪ Press the push button .
▪ LED goes ON.
If Link test is satisfactory
▪ LED goes OFF.
▪ Mount the front cover again.
Installation Guide6
DEVIlink™ RU
If Link test is unsatisfactory
▪ LED flashes 5 times.
If the transmission between DEVIlink™ RU Repeater Unit
and DEVIlink CC is not successful
1. Try to relocate the DEVIlink™ RU Repeater Unit.
2. Or install additional DEVIlink™ RU Repeater Units (up
to three)
3�2 Factory reset
▪ Disconnect the DEVIlink™ RU Repeater Unit from the
power supply.
▪ Release the round front cover hiding push button
▪ Press and hold down the push button .
▪ Meanwhile plug in the power supply again.
▪ Release the push button when the LED goes ON
and OFF.
4 Symbols
LED modes:
▪ LED permanent lighting – ON
▪ No LED light – OFF
7Installation Guide
DEVIlink™ RU
5 Radio Equipment Directive
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Danfoss A/S declares that the radio equipment type
DEVIlink™ RU is in compliance with Directive 2014/53/EU
The full text of the EU declaration of conformity is available
at the following internet address: devi�danfoss�com
6 Warranty
YEAR
WARRANTY
7 Disposal instructions
Installation Guide8
DEVIlink™ RU
9Installation Guide
DEVIlink™ RU
Installation Guide10
DEVIlink™ RU
Danfoss A/S
Electric Heating Systems
Ulvehavevej 61
7100 Vejle
Denmark
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products
without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary
in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logo-type are trademarks of
Danfoss A/S. All rights reserved