Logic Elements Technical Information
3 to 2
Pressure Drop
Flow
3 to 4, 2 blocked
psi
bar
33 cSt [154 SUS] hyd.oil @ 38° C [100° F]
40
0
0
0
80
120160
200
240
10.6
21.131.7
42.3
52.8
63.4
44
87
131
174 12
9
6
3
US gal/min
l/min
Pressure Drop
Pressure Compensator
CP313-6
OPERATION
The CP313-6 is a 20-size, load sense, priority, static, pressure compensator. The valve will provide
on-demand priority ow to port 2 in the required amount (dependent on the load sense pressure
on port 1), allowing the excess ow to go to auxiliary functions through port 4.
APPLICATION
Common applications include steering circuits that require pre-compensated, priority ow
to go to the steering system, and the excess ow will go to an auxiliary function, like a fan
motor. To obtain dynamic load sensing (priority type pre-comp) add in orice between ports
2 and 1 in the manifold. This provides faster response and is commonly used in steering to
ush out LS line. See Circuit Example.
SPECIFICATION
Rated pressure 210 bar [3045 psi]
Rated ow at 7 bar
[100 psi]
Weight 1.33 kg [2.93 lb]
Cavity SDC20-4
200 l/min
[53 US gal/min]
PERFORMANCE CURVE
SCHEMATIC
Theoretical performance
BC332375783111en-000101 • February 2020
LE - 83
DIMENSION
mm [in]
Logic Elements Technical Information
Pressure Compensator
CP313-6
Cross-sectional view
1
EXAMPLE CIRCUITS
2
3
1-5/8-12 UN THD
4
h
1.88 in
t
217 - 231 N.m
58.6
[160 - 170 lbf.ft]
[2.31]
BC332375783111en-000101 • February 2020
ORDERING
INFORMATION
CP313-6-B-16S -080
Seal kit
B=Buna-N 120181
V=Viton 120182
rtsHousing P/N
0=No Housing No Housing
8B = AL,1 BSP CP20-4-8B
10B = AL, 1-1/4 BSP CP20-4-10B
16S = AL, #16 SAE CP20-4-16S
20S = AL, #20 SAE CP20-4-20S
ther housings available
Co
bar[psi]
050=3.4[50]
080=5.5[80]
100=6.9[100]
130=9.0[130]
150=10.3 [150]
LE - 84