Danfoss CP310-2 Technical Information

Danfoss CP310-2 Technical Information

Flow Control Valves Technical Information

Adjustable, Priority Type

CP310-2

OPERATION

This valve is a limited adjustment,

Schematic

 

 

pressure compensated, priority-type flow

 

 

 

control valve.

 

 

 

 

1

3

SPECIFICATIONS

Theoretical performance

2

 

gpm

L/min

154 SUS (33 cSt) hyd. oil @ 100° F (38° C)

 

 

 

 

13.2

 

50

regulated pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.9

 

45

secondary pressure

 

 

 

Specifications

 

 

10.6

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated pressure

210 bar [3000 psi]

 

9.2

 

35

 

 

 

 

 

 

 

 

7.9

<![if ! IE]>

<![endif]>Flow

30

 

 

 

 

 

 

 

Max regulated flow

22.7 l/min

 

6.6

25

 

 

 

 

 

 

 

 

[6 US gal/min]

 

 

 

 

 

 

 

 

 

 

 

5.3

 

20

 

 

 

 

 

 

 

Max inlet flow

38 l/min

 

4

 

15

 

 

 

 

 

 

 

 

[10 US gal/min]

 

2.6

 

10

 

 

 

 

 

 

 

Weight

0.24 kg [0.52 lb]

 

 

 

 

 

 

 

 

 

 

 

 

1.3

 

5

 

 

 

 

 

 

 

Accuracy ± 20%

0.4- 1.88 l/min

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[0.1-0.49 US gal/min]

 

 

 

bar

30

60

90

120

150

180

210

 

 

 

 

 

 

 

Pressure

 

 

 

± 15%

1.89-5.67 l/min

 

 

 

psi

435

870

1305

1740

2176

2611

3046

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[0.5-1.49 US gal/min]

 

 

 

 

 

 

 

 

 

 

 

± 10%

5.68-22.7 l/min

DIMENSIONS

Cross-sectional view

 

 

 

 

 

[1.5-6 US gal/min]

mm in

 

Flow Adjustment Range

± 25% of normal setting

 

 

Cavity

SDC10-3

 

 

h 1.00 in

 

 

 

t 41-47 N.m

 

7/8-14 UNF

[30-35 lbf.ft]

 

 

 

 

 

Type A

Type E

 

 

adjustment

1

 

adjustment

 

 

 

Type F

 

 

 

Type K

 

 

adjustment

2

3

 

adjustment

80.0 max.

 

 

 

 

46.2

55.9

[3.15]

 

 

 

[1.82]

[2.20]

 

 

ORDERING

 

 

 

 

CP31 0 - 2 - B - 8 S - A - 2.5

 

 

 

 

 

INFORMATION

Seals

 

Seal kit

 

 

 

 

 

 

 

 

 

 

 

Regulated

 

 

B

= Buna-N

120240

 

 

 

 

 

 

 

 

Flow

 

 

 

V

= Viton

 

11043064

 

 

L/min

[US gal/min]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

= .4

[0.1]

 

Housing and ports

 

Housing P/N

 

 

 

To

 

 

0

=

No Housing

No Housing

 

 

6.0

= 22.7

[6.0]

 

SE3B

=

Al, 3/8 BSP

SDC10-3-SE-3B

Adjustment option

 

 

SE4B

=

Al, 1/2 BSP

SDC10-3-SE-4B

 

 

6S

=

Al, #6 SAE

CP10-3-6S

A

=

Internal

 

 

8S

=

Al, #8 SAE

CP10-3-8S

E

=

External

 

 

Other housings available

 

F

=

Tamper resistant

 

 

 

 

 

 

K

=

Knob

 

BC332375569107en-000101 • February 2020

 

 

 

 

 

 