Danfoss CP241-8 Technical Information

Sequence Valves Technical Information
Seals
B= Buna-N V=
2-Way, Normally Closed CP241-8
CP241-8
OPERATION
SPECIFICATIONS
DIMENSIONS
mm [in]
Valve blocks ow from 1 to 2 until sucient pressure is applied at 1.
Schematic
Theoretical performance
psi bar
200
14
10
150
100
7
Press ure drop
3
50
Specications
Rated pressure 210 bar [3000 psi]*
0
L/min
US gal/min
38
10
76
114
Flow
20 30 40
151
189
Rated ow at 7 bar
[100 psi]
50
Weight 0.41 kg [0.90 lb]
150 l/min
[39 US gal/min]
Cavity CP12-3S
*Maximum 1500 psi pressure dierential allowed between ports
Cross-sectional view
3
2
1
55.5
[2.19]
ORDERING INFORMATION
1 1/16-12UN
61.087 [2.41]
62.3
[2.45]
CP241-8-B-10S-A-C-050
Seal kit
Viton 120681
120680
3
2
A option
1
F option
55.5
[2.19]
Pressure range
A= 1-10 bar [13-150 psi] B= 3.4-28 bar [50-400 psi] C= 5.5-41 bar [80-600 psi]
Housing and portsHousing P/N
0=No Housing No Housing 4B =Al, 1/2 BSP CP12-3S-4B/2B 6B =Al, 3/4 BSP CP12-3S-6B/2B
10S=Al,#10 SAE CP12-3S-10S/4S 12S=Al,#12 SAE CP12-3S-12S/4S
Other housings available
h 1.25 in t 68-75N.m
[50-55 lbf.ft]
81.3 max
[3.20]
Pressure setting
Code x 10psi (0.69 bar) Example: 050 = 500 psi (35 bar)
Adjustment option
A= Internal
E= External F=Tamper resistant
K= Knob
E option
K option
BC332375508106en-000101 • February 2020