Danfoss CP241-21 Technical Information

Danfoss CP241-21 Technical Information

 

 

 

 

 

Sequence Valves Technical Information

 

 

 

 

 

 

 

 

 

 

Pilot Operated Spool

 

 

 

 

 

 

 

 

 

 

CP241-21

OPERATION

 

Valve is a pilot-operated sequence valve that blocks flow from 1 to 2 until sufficient

 

 

 

 

pressure is applied at 1.

 

 

 

 

 

Schematic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Theoretical performance

 

 

 

 

 

 

 

psi

 

 

bar

154 SUS (33 cSt) hyd. oil @ 100° F (38° C)

 

 

 

4351

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3626

 

 

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2901

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>drop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2176

<![if ! IE]>

<![endif]>Pressure

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1450

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

725

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L/min

20

40

60

80

100

120

 

 

 

 

 

 

 

 

 

 

Flow

 

 

 

 

 

 

 

 

US gal/min

5.3

 

 

 

 

 

 

31.7

 

 

10.6

15.9

21.1

26.4

Specifications

Rated pressure

350 bar [5075 psi]

Rated flow at 7 bar

75 l/min

[100 psi]

[20 US gal/min]

Weight

0.17 kg [0.37 lb]

Cavity

CP12-3S

DIMENSIONS

Cross-sectional view

mm [in]

h 1.25 in t 68-75 N.m

[50-55 lbf.ft]

55.4

37.3

[2.18]

[1.47]

1

2 3

1 1/16-12 UN

 

57.9 max

 

[2.28]

Type A

Type E

adjustment

adjustment

 

Type F

Type K

adjustment

adjustment

 

ORDERING

INFORMATION

CP241 - 21 - B - 6S - A - C - 150

Seals

 

 

 

 

Seal kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

=

Buna-N

120335

 

 

 

 

 

 

 

 

 

 

V

=

Viton

120336

 

 

 

 

 

 

 

 

 

 

Housing and ports

 

 

Housing P/N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

=

No Housing

 

No Housing

 

4B

 

 

=

Al, 1/2 BSP

CP12-3S-4B/2B

 

6B

 

 

=

Al, 3/4 BSP

CP12-3S-6B/2B

 

10S

 

 

=

Al, #10 SAE

CP12-3S-10S/4S

 

12S

 

 

=

Al, #12 SAE

CP12-3S-12S/4S

 

Other housings available

 

 

 

 

 

 

 

 

 

 

 

Adjustment option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

=

Internal

 

 

 

 

 

 

 

 

 

 

 

E

 

=

External

 

 

 

 

 

 

 

 

 

 

 

F

 

=

Tamper resistant

 

 

 

 

 

 

 

 

 

 

 

K

 

=

Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

Crack pressure

Code x 10 = psi Example: 150 = 1500 psi

Pressure range

 

 

 

bar

[psi]

A

=

14-55

[200-800]

Standard

28

[400]

B

=

21-103

[300-1500]

Standard

69

[1000]

C

=

28-207

[400-3000]

Standard

103

[1500]

D

=

28-345

[400-5000]

Standard

103

[1500]

BC332375508106en-000101 • February 2020

SQ - 11

Loading...