Danfoss CP240-1 Technical Information

Sequence Valves Technical Information
11
14
17
20
2
1
3
t
t
1
Ad
Seals
[100-1400]
[500-2400]
Housing and po
O
2-Way, Normally Open CP240-1
OPERATION
SPECIFICATIONS
DIMENSIONS
mm [in]
This valve is a direct acting, spool type sequence valve with internal pilot. This valve allows ow from 2 to 3 and blocks 1. At reaching the sequence pressure 1 is opened to 2.
Schematic
Theoretical performance
psi bar
3
4
5
6
87
58
29
14
12
10
8
3
2
6
Press ure drop
4
2
0
8L/min
2.1US gal/min
1
2
Fully opened
16 24 32 40
Flow
4.26.3 8.5 10.6
Specications
Rated pressure 210 bar [3000 psi]
Rated ow at 7 bar
[100 psi]
Weight 0.25 kg [0.56 lb]
Cavity SDC10-3
25 l/min
[7 US gal/min]
Cross-sectional view
7/8-14 UNF
23
Seq
46.4
[1.83]
Tank
55.9
[2.20]
ORDERING INFORMATION
B=Buna-N 120009 V=Viton 120010
0=No Housing No Housing SE3B=Al,3/8 BSP SDC10-3-SE-3B SE4B=Al,1/2 BSP SDC10-3-SE-4B
6S =Al, #6 SAE CP10-3-6S 8S =Al, #8 SAE CP10-3-8S
ther housings available
justment option
A= Internal
E= External
F= Tamper resistant
K= Knob
rtsHousing P/N
BC332375508106en-000101 • February 2020
ht1.00 in
41-47 N.m
[30-35 lbf.ft]
Type A adjustment
Type F adjustment
Seal kit
CP240-1-B-6S-A-C-100
25.4 [1.00"] hex
80.0 max.
[3.15]
Crack pressure
Code x 10 = psi Example: 100 = 1000 psi
Pressure range
A= 4-28 [50-400]
Std. setting 17 [250]
B= 5-55 [75-800]
Std. setting 28 [400]
C= 7-97
Std. setting 69 [1000]
D= 34-166
Std. setting 103 [1500]
bar [psi]
Type E adjustmen
Type K adjustmen
SQ - 17
Loading...