Pressure Reducing Valves Technical Information
Pressure Reducing, Non-Relieving, Pilot Operated
CP230-4
OPERATION
SPECIFICATIONS
DIMENSIONS
mm [in]
This is a pilot-operated pressurereducing (non-relieving) valve.
Theoretical performance
psi bar
1
0
0
0
870
580
290
154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
140
120
100
80
60
Press ure
40
20
0
10L/min
20 30 40 50 60
2.6US gal/min
5.3 7.9 10.6 13.2 15.
Flow
Cross-sectional view
7/8 -14 UNF THD
Schematic
Specications
Rated pressure 350 bar [5000 psi]
Rated ow at 7 bar
[100 psi]
Weight 0.20 kg [0.43 lb]
Cavity SDC10-3
64-73 Nm
[47-54 lbf*ft]
40 l/min
[11 US gal/min]
1
Regulated
2
Pressure
46.2
ORDERING
INFORMATION
B=Buna-N 120027
V=Viton 120028
0=No Housing No Housing
SE3B=Al,3/8 BSP SDC10-3-SE-3B
SE4B=Al,1/2 BSP SDC10-3-SE-4B
6S =Al, #6 SAE CP10-3-6S
8S =Al, #8 SAE CP10-3-8S
ther housings available
justment option
A= Internal
E= External
F= Tamper resistant
K= Knob
rtsHousing P/N
BC332375439105en-000101 • February 2020
3
Tank
Seal kit
41.7
CP230-4-B-6S-A-C - 150
Type A
adjustment
Type F
adjustment
Pressure setting
Code x 10psi (0.69 bar)
Example: 150 = 1500 psi (105 bar)
Pressure range
A= 14-55 [200-800]
Standard 28 [400]
B= 21-103
Standard 69 [1000]
C= 28-207
Standard 103 [1500]
D= 28-345
Standard 103 [1500]
bar [psi]
PR - 8