Danfoss CP128-1 Technical Information

Danfoss CP128-1 Technical Information

Shuttle Valves Technical Information

Load Shuttle Valve - Normal Direction

CP128-1

OPERATION

This valve senses the higher of the two

 

input pressures at ports 1 and 3 and

 

routes it to the output port 2.

 

SPECIFICATIONS

Theoretical performance

 

 

 

 

 

 

Pressure drop

 

 

psi

bar 26 cSt [121 SUS] hyd.oil at 50ƱC [122 ƱF]

 

150

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

3-2

 

 

 

 

 

 

 

 

 

 

100

6

 

 

 

 

 

1-2

 

 

 

 

 

 

 

 

 

50

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

0

0

5

10

15

20

25

30 l/min

 

 

 

 

 

 

0

2

4

 

6

8 gal/min

Schematic

2

1

3

Specifications

Rated pressure*

315 bar [4570 psi]

Rated flow at 7 bar

22 l/min

[100 psi]

[5.8 US gal/min]

Leakage

6 drops/min @

 

Rated pressure

Weight

0.06 kg [0.14 lb]

Cavity

SDC08-3

*Rated pressure based on NFPA fatigue test standard (at 1 million cycles)

DIMENSIONS

Cross-sectional view

mm [in]

 

22 mm [0.866 in]

3/4-16 UNF

27-34 Nm [20-25 lbf*ft]

1.0

 

 

[0.04]

 

1

<![if ! IE]>

<![endif]>Ø 15.9 [Ø 0.62]

<![if ! IE]>

<![endif]>Ø 22.0 [Ø 0.87]

 

<![if ! IE]>

<![endif]>Ø14.3 [Ø0.56]

3

2

 

 

6.0

41.9

 

 

[0.24]

[1.65]

 

 

ORDERING INFORMATION

CP128-1-B-0

Load Shuttle Valve

Normal Direction

 

 

 

 

Seal

Option

Seal kit

 

B = Buna-N

120238

 

V = Viton

120239

 

Code

Ports & Material

Body Nomenclature

0

0 = Cartridge only

No Body

SE2B

AL, 1/4 BSP

SDC08-3-SE-2B

SE3B

AL, 3/8 BSP

SDC08-3-SE-3B

4S

AL, #4 SAE

CP08-3-4S

6S

AL, #6 SAE

CP08-3-6S

**Aluminum bodies to be used for pressures less than 210 bar (3000 psi)

***Other housings available

BC332375309103en-000101 • February 2020