Shuttle Valves Technical Information
Load Shuttle Valve - Normal Direction
CP128-1
OPERATION |
This valve senses the higher of the two |
|||||||
|
input pressures at ports 1 and 3 and |
|||||||
|
routes it to the output port 2. |
|
||||||
SPECIFICATIONS |
Theoretical performance |
|
|
|||||
|
|
|
|
Pressure drop |
|
|||
|
psi |
bar 26 cSt [121 SUS] hyd.oil at 50ƱC [122 ƱF] |
||||||
|
150 |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 |
|
|
|
|
3-2 |
|
|
|
|
|
|
|
|
|
|
|
100 |
6 |
|
|
|
|
|
1-2 |
|
|
|
|
|
|
|
|
|
|
50 |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
0 |
0 |
5 |
10 |
15 |
20 |
25 |
30 l/min |
|
|
|
||||||
|
|
|
0 |
2 |
4 |
|
6 |
8 gal/min |
Schematic
2
1 |
3 |
Specifications
Rated pressure* |
315 bar [4570 psi] |
Rated flow at 7 bar |
22 l/min |
[100 psi] |
[5.8 US gal/min] |
Leakage |
6 drops/min @ |
|
Rated pressure |
Weight |
0.06 kg [0.14 lb] |
Cavity |
SDC08-3 |
*Rated pressure based on NFPA fatigue test standard (at 1 million cycles)
DIMENSIONS |
Cross-sectional view |
|
mm [in] |
|
|
22 mm [0.866 in] |
3/4-16 UNF |
|
27-34 Nm [20-25 lbf*ft] |
||
1.0 |
||
|
||
|
[0.04] |
|
1 |
<![if ! IE]> <![endif]>Ø 15.9 [Ø 0.62] |
<![if ! IE]> <![endif]>Ø 22.0 [Ø 0.87] |
|
<![if ! IE]> <![endif]>Ø14.3 [Ø0.56] |
||
3 |
2 |
|
|
6.0 |
41.9 |
|
|
[0.24] |
[1.65] |
|
|
ORDERING INFORMATION
CP128-1-B-0
Load Shuttle Valve
Normal Direction
|
|
|
|
Seal |
Option |
Seal kit |
|
B = Buna-N |
120238 |
|
|
V = Viton |
120239 |
|
Code |
Ports & Material |
Body Nomenclature |
0 |
0 = Cartridge only |
No Body |
SE2B |
AL, 1/4 BSP |
SDC08-3-SE-2B |
SE3B |
AL, 3/8 BSP |
SDC08-3-SE-3B |
4S |
AL, #4 SAE |
CP08-3-4S |
6S |
AL, #6 SAE |
CP08-3-6S |
**Aluminum bodies to be used for pressures less than 210 bar (3000 psi)
***Other housings available
BC332375309103en-000101 • February 2020 |