Shuttle Valves Technical Information
Load Shuttle Valve - Normal Direction
CP124-1
OPERATION
SPECIFICATIONS
DIMENSIONS
mm [in]
This valve senses the higher of the two
input pressures at ports 1 and 3 and
routes it to the output port 2.
Theoretical performance
psi bar
203
174
145
116
87
58
154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
14
12
10
8
6
Press ure drop
4
2029
1L/min
0.3US gal/min
2
3
12
234
Flow
0.5 0.8 1.1
Cross-sectional view
Schematic
Specications
Rated pressure* 350 bar [5075 psi]
Rated ow at 7 bar
[100 psi]
Leakage 6 drops/min @
Weight 0.02 kg [0.04 lb]
Cavity CP04-3
*Rated pressure based on NFPA fatigue test
standard (at 1 million cycles)
3.7 l/min
[1 US gal/min]
Rated pressure
ORDERING
INFORMATION
1
2
B=Buna-N 120111
V=Viton 120282
7/16-20 UNF
3
36.8
[1.45]
CP124-1-B-4S
Seal kit
I 0.188 in
10-15 N.m
t
[8-10 lbf.ft]
2.5
[0.10]
Housing and portsHousing P/
0=No Housing No Housing
2B =AL, 1/4 BSP CP04-3-2B
4S =AL,#4 SAE CP04-3-4S
Other housings available
BC332375309103en-000101 • February 2020