SELECTING THE OPERATING MODE
Behind the flap are two SELECT buttons, one each for Central Heating
( ) and Hot Water ( ). The operating modes available are: ON - The output is on constantly. OFF - The output is off constantly,
unless +1HR is pressed. AUTO - The output switches on and off to the set programme. ALLDAY - The output switches on at Setting 1, then stays on
until Setting 4.
MANUAL OVER-RIDES
While in OFF, AUTO or ALLDAY modes the plus one hour (+1HR) button can be used to switch from off to on for just one hour, or to extend an existing on period by one hour. The extra hour is cancelled by pressing the button again, pressing the MAN button, or when an on event is reached.
While in AUTO or ALLDAY modes pressing the manual (MAN) button will switch an output which is on to off, and vice versa. This over-ride will last only until the next programmed switching event is reached, when the automatic programme will resume control, or until the button is pressed again.
When the above over-rides are selected a bar appears in the display against the appropriate legend.
RESET
Should the unit be disconnected from the mains a small battery
symbol will blink on the left hand side of the display. After the second
midnight, i.e. between 24 and 48 hours, the display will go blank and
the unit will lose its settings. When mains power is restored it is
recommended that the unit be reset by lowering the front flap and
using a small non-metallic object, e.g. matchstick, press and release
the recessed reset button (marked R/S). This installs the factory pre-
set programme and sets the time to 12:00pm on Monday (MO). The
outputs will be OFF, (see Fig. 1). Note that the colon between the
hours and minutes is blinking. This means the unit is in RUN mode and
will switch the Central Heating and Hot Water on and off in accordance
with the programme. The colon only blinks in RUN mode.
CHOICE OF 12 HR OR 24 HR CLOCK
At any time during RUN mode the time displayed can be toggled
between a 12 hour clock with am/pm indication or a 24 hour clock by
pressing and holding both DAY and NEXT ON/OFF buttons for 1·5
seconds.
G.M.T. / B.S.T.
While in RUN mode the change from Greenwich Mean Time to British
Summer Time and back is achieved by pressing and holding the +
button to add one hour in the Spring, or the - button to put the clock
back in the Autumn. After the first time this change has been made this
feature will only allow the clock to be changed in the correct direction.
Take care when making this change for the first time. If it is made in
the wrong direction the unit will have to be reset and any user-settings
re-entered.
SETTING THE CLOCK & PROGRAMMES
1) Pressing PROG once enters SET TIME mode, see Fig. 2. While
setting the time, pressing and releasing the + or - buttons will
change the time by one minute; pressing and holding down + or
- will change the time quickly in ten minute steps. (This also
applies when adjusting the ON/OFF times). Use DAY button to set
day. When the time and day are correct, press the PROG button
once to start the clock and go to SET ON TIME mode.
USER INSTRUCTIONS
CP10C -24 hour programmer with separate outputs
for Heating & Hot Water.
Features include:
- Simple change between GMT & BST
- 12 hour or 24 hour clock
- 2 on's/2 off's with manual over-rides
- Battery back-up
2) CHECKING/ADJUSTING PROGRAMMES: Pre-set programmes
may be checked using the NEXT ON/OFF button to step through
the four available settings, which can be changed if required using
the + or - buttons. The display now shows SET OFF TIME, with
OFF blinking.
3) RUN MODE: Having completed the programming, press PROG to
go to the run mode.
RUN MODE
OPERATION: In RUN mode the unit will automatically switch the
Central Heating and Hot Water on and off at the times set. However,
useful over-rides are provided which enable the user to make temporary
changes to the ON/OFF times without having to re-programme the
unit. The facilities offered by the over-rides are detailed on the back
cover.
REVIEWING PROGRAMMES FROM THE RUN MODE: Press PROG
twice, follow steps 2 & 3) above.
Part No: 8442 Iss.3. 08/99
Danfoss Randall Ltd.
Ampthill Road Bedford, MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: danfossrandall@danfoss.com Website: www.danfoss-randall.co.uk
Sequence of button presses whilst adjusting time, day and programme settings. Read the section Error free programming first.
Press and release + or - to change the time by one minute. Press and hold down + or - to change the time quickly.
BUTTON
SEQUENCE
ACTION
STEP PRESS
STARTING FROM RUN MODE,
Fig. 1 - Colon blinking
1 PROG Go to SET CLOCK mode. (Fig. 2)
2 DAY Select current day of week. (for display only)
3 + or - Adjust time of day.
4 PROG
Start clock and display Central Heating and Hot Water ON/OFF times. (Fig.3)
5 + or - Adjust first event ON time.
6
NEXT/ON/OFF
Step forward to first event OFF time.
7 -
Repeat steps 5 & 6 for second event ON/OFF times. (Figs. 3, 4 & 5)
8 PROG
Complete programming and return to run mode, colon blinks.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
ERROR FREE PROGRAMMING.
ON/OFF times cannot be set out of sequence. The limits of adjustment are: Setting 1 (first ON) 12:00am to 11:59pm (normally in the morning). Settings 2 to 4 (first OFF to last OFF) anywhere between the previous Setting and 23 hours 59 minutes
after Setting 1. The - button stops responding when the previous Setting is reached, but the + button continues to its
limit, also changing any later Settings that would have been overlapped. While becoming familiar with the Setting Sequence the ON/OFF times may become grouped together.
If this should happen use NEXT ON/OFF to select Setting 1, then check/alter each Setting in turn, using + or -, until the desired programme is entered.
NOTES ON TYPICAL DISPLAYS (See left)
Fig. 1 Immediately following a manual RESET [RUN mode with colon blinking] Fig. 2 SET TIME and DAY mode [colon steady, day, hours and minutes blink] Fig. 3 SET FIRST EVENT ON TIME
[setting number and programming period shown, ON blinks]
Fig. 4 SET FIRST EVENT OFF TIME
[setting number and programming period shown, OFF blinks]
Fig. 5 SET LAST EVENT PROGRAMMED FOR OFF TIME AFTER MIDNIGHT
[programming period when output will switch off blinks]
Fig. 6 Typical CH ALLDAY, HW AUTO programme with HW +1 HOUR selected.
IMPORTANT NOTES
A) Day of week is for display purposes only. B) The COPY button on CP10C has no function, please disregard. C) Should the unit be disconnected from the mains a small battery symbol will blink
on the left hand side of the display.
FACTORY PRE-SET PROGRAMME
The following ON/OFF times are programmed at the factory and are re-instated by pressing the recessed R/S button behind the flap.
semmargorPtes-erPyrotcaF
gnitteSFFO/NOemiT
1 2 3 4
NO
FFO
NO
FFO
MA03:6 MA03:8 MP00:5 MP03:01